  1. are you saying you have a 4 ton on 1800 sq. ft.? ...

    are you saying you have a 4 ton on 1800 sq. ft.? How hot is the attic getting? Did you have a new roof installed? and if so is it black or dark? If a new roof are there any openings in the roof to...
  2. Replies
    25
    Views
    646

    If you are talking about YOUR house you have to...

    If you are talking about YOUR house you have to give us information. We are answering from what we see in the field. When I was in atlanta you ALWAYS had at least one complete system in the attic. ...
  3. Replies
    5
    Views
    261

    This is not brutal. 100 + temps are brutal,...

    This is not brutal. 100 + temps are brutal, working in an attic that is over 140 is brutal, working in the hot sun with no breeze in over 90 temps is uncomfortable. I would love to see highs under...
  4. trane's all aluminum condenser coils was the only...

    trane's all aluminum condenser coils was the only thing I saw that would stand up to the salt air. The copper is what I saw leaking on the tranes. And none of the manufactures lasted like trane. ...
  5. This is what I was saying.

    This is what I was saying.
  6. I would think that a 1.5 ton unit is over sized...

    I would think that a 1.5 ton unit is over sized for your garage so at the warmer temp (72) it does not run long enough to remove the humidity. Like what was previously asked what size was your...
  7. Replies
    14
    Views
    549

    my blue book says nothing about a GB-2100 but it...

    my blue book says nothing about a GB-2100 but it does have the following.

    GB-1103, -1104, -1105, -1106, -1107
    GB-1202, -1203, -1204, -1205
    GB-1504, -1505, -1506, -1508
    GB-2203
    GB2102, GB2103,...
  8. Replies
    11
    Views
    515

    you will probably want to go to metal duct and...

    you will probably want to go to metal duct and get away from the duct board and flex duct. it will cost more but no animals/critters will get in to it.
  9. I was wondering if this was going to be noticed.

    I was wondering if this was going to be noticed.
  10. Replies
    8
    Views
    406

    You as an electrician may not have to work the...

    You as an electrician may not have to work the kind of hours we work in the extremes. So yea on a holiday we do want to spend time with our family just like most people out there. Now I am pretty...
  11. Replies
    4
    Views
    233

    yea look at why the fan motor is shutting off.

    yea look at why the fan motor is shutting off.
  12. Thread: Trane xe1200

    by DOGBOY
    Replies
    15
    Views
    422

    on some tranes you need to use oem motors as the...

    on some tranes you need to use oem motors as the generic will not last long. I believe this is true on the xe1000 not sure about the xe1200's though.
  13. Replies
    57
    Views
    2,689

    so how is the answer yes? As beenthere stated...

    so how is the answer yes? As beenthere stated your duct work must have the minimum restrictions for it to move 3000 cfm of air and I yet have seen a system with .1 or less static pressure. I am...
  14. bingo!

    bingo!
  15. So you guys are having good luck using evaps from...

    So you guys are having good luck using evaps from 22 to 410a? Providing that it is listed both ways?
  16. Replies
    17
    Views
    2,785

    who ever installed it did not install a filter...

    who ever installed it did not install a filter drier.
  17. the best I got was a $1000 one sunday. I got...

    the best I got was a $1000 one sunday. I got there replaced the run cap on main level a/c and he gave me a check for the repair and 10 $100 bills.
  18. Replies
    17
    Views
    2,785

    found that in a piston once but also had a faulty...

    found that in a piston once but also had a faulty compressor also. Always thought it came from comp windings.
  19. Replies
    3
    Views
    390

    20 to 25 years out of any system today in my...

    20 to 25 years out of any system today in my opinion is not realistic.
  20. Thread: Furnace Filters

    by DOGBOY
    Replies
    7
    Views
    599

    black dirt on inside of house has to be soot. ...

    black dirt on inside of house has to be soot. From candles or exhaust on furnace. Never stated if you have a fireplace but that can put soot in to the house like crazy.
  21. Thread: DB levels

    by DOGBOY
    Replies
    4
    Views
    350

    Higher efficient equipment is usually quieter. I...

    Higher efficient equipment is usually quieter. I always recommend higher eff. equipment when it is near a porch or deck.
  22. Replies
    7
    Views
    409

    DUH

    DUH
  23. Replies
    9
    Views
    492

    you have 2 systems.

    you have 2 systems.
  24. Replies
    26
    Views
    1,157

    he did not say warranty just direct replacement. ...

    he did not say warranty just direct replacement. Slide out slide in.
  25. had a company install a new evaporator in a...

    had a company install a new evaporator in a neighbors house it was a 21 inch coil and they replaced it with a 14 inch wide one and never sealed the opening so a lot of air was bypassing the coil. ...
  26. Replies
    8
    Views
    524

    neither one of those parts will cause the unit to...

    neither one of those parts will cause the unit to misfire as you stated. They only start it and allow it to stay running. It is another part that has been discontinued.
  27. Replies
    8
    Views
    639

    as was stated earlier an aluminum coil will be a...

    as was stated earlier an aluminum coil will be a good fix.

    and for them covering it under warranty will an automaker cover a faulty or leaking radiator, heater core or evaporator coil, 2 years...
  28. Replies
    8
    Views
    492

    You will find out that when it does go out either...

    You will find out that when it does go out either in the heat of summer or cold of winter you may just have to wait a week to 2 to get the new one in. Since most all companies are the busiest when...
  29. I love the way people do not accept answers from...

    I love the way people do not accept answers from people who know about the subject but will listen to people who have not a clue what they are talking about. The correct answer was given in the...
  30. Replies
    14
    Views
    804

    120 degree attic is a cool attic when they get...

    120 degree attic is a cool attic when they get over 140 then they are a hot attic. I have seen too many over 160 and some over 180. Had one one time that was 198 but the roofer did not cut any...
  31. you gotta love it when people start double or...

    you gotta love it when people start double or tripling up on filters. Especially the real restrictive ones. They need to try and put 2 or 3 of those nose/mouth filters on when they push the mower...
  32. Replies
    8
    Views
    756

    .3"? Oh I am sure they are at or below that...

    .3"? Oh I am sure they are at or below that number.
  33. I personally do not think you will accomplish...

    I personally do not think you will accomplish what you want with thermostats. Your neighbors not only got a $800/yr savings but their comfort level has increased and what is that worth to you/them?
  34. Replies
    12
    Views
    967

    I would say outdoor stat to lock out heatpump in...

    I would say outdoor stat to lock out heatpump in heat mode above 65.
  35. Replies
    17
    Views
    1,293

    I have had to pressure 410 up to 400# to locate...

    I have had to pressure 410 up to 400# to locate the dang leaks. I think the oil seals the leak to a point and especially when pulling a vacuum. Making them harder to find.
  36. Replies
    22
    Views
    1,297

    In 2001 the standard efficiency was 10 seer in...

    In 2001 the standard efficiency was 10 seer in 2006 it went to 13 seer in 2015 depends on where you are located it went to 14 seer. That alone is higher. So in 2001 if you purchased a 10 seer...
  37. Thread: condenser swap?

    by DOGBOY
    Replies
    7
    Views
    564

    4 tons on a 1600 square foot house? I had a 2...

    4 tons on a 1600 square foot house? I had a 2 ton on my 1600 square foot house in atlanta. But we know not where you are from to know if it is too much.
  38. at 30 years old, dude put it to rest already. ...

    at 30 years old, dude put it to rest already. You are past the borrowed time by at least 10 years.
  39. Replies
    16
    Views
    1,069

    Maybe this will help?

    Maybe this will help?
  40. Replies
    16
    Views
    1,069

    The communicating t-stats are completely...

    The communicating t-stats are completely different than standard t-stats, the econet is a communicating t-stat and does not operate off of batteries and your furnace is 2 stage that is why you will...
  41. Thread: Trane coil size

    by DOGBOY
    Replies
    6
    Views
    323

    the coil can cover multiple sizes as stated. we...

    the coil can cover multiple sizes as stated. we need to know the model number of the outdoor unit to know how many btu's (size) it is rated at.
  42. Replies
    7
    Views
    426

    If it is refrigerant equalizing. I would say not...

    If it is refrigerant equalizing. I would say not much of a chance however something could be rubbing or touching something that it should not be. The service tech should be able to explain it in...
  43. Replies
    7
    Views
    405

    can u get an accurate amp reading off of an ecm...

    can u get an accurate amp reading off of an ecm motor?
  44. Replies
    5
    Views
    1,909

    came up on a trane xl1200 package heat pump that...

    came up on a trane xl1200 package heat pump that some one replaced the cond. fan motor. Home owner called complaining about a noise and found the shaft had started drilling a hole in the top of the...
  45. Replies
    6
    Views
    352

    yea turn fan on go outside and barely open an...

    yea turn fan on go outside and barely open an outside door and feel it is pushing air out or sucking air in to the house.
  46. Replies
    10
    Views
    456

    according to OP's math you should have a 4 ton.

    according to OP's math you should have a 4 ton.
  47. Replies
    57
    Views
    2,689

    It will in no way move 3000 cfm of air. 2000 max.

    It will in no way move 3000 cfm of air. 2000 max.
  48. Replies
    21
    Views
    614

    my question is why is the 1 1/2" line stopping...

    my question is why is the 1 1/2" line stopping up? Do you know if it goes straight to the sewer or is it a vent? And is anything else backing up?
  49. Replies
    3
    Views
    382

    close the the ocean trane/american standard is...

    close the the ocean trane/american standard is the only way to go.
  50. Replies
    57
    Views
    2,689

    A smaller ac will keep the humidity lower so that...

    A smaller ac will keep the humidity lower so that you do not have to set it at 70. The smaller ac is running longer to remove more humidity but is using less electricity to do so. It is cost more...