Search:

Type: Posts; User: MechAcc

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    5
    Views
    843

    Check out Allied Electronics they have several...

    Check out Allied Electronics they have several sizes.

    http://www.alliedelec.com/search/results.aspx?term=molex+extraction+pin+tool
  2. Thread: Mag Jumpers

    by MechAcc
    Replies
    24
    Views
    1,836

    They can be used on heat pump reversing valves to...

    They can be used on heat pump reversing valves to see if slider is moving.

    http://www.youtube.com/watch?v=j2riZP1nOD0
  3. Cooper MFM 300 uses transducers that connect to...

    Cooper MFM 300 uses transducers that connect to gauge port even less refrigerant wasted than stubby gauges.
  4. Welcome to RSES. I have enjoyed the education and...

    Welcome to RSES. I have enjoyed the education and friends that I have made since joining in 91
  5. The Technical Institute Manuals are 3 Volumes...

    The Technical Institute Manuals are 3 Volumes
    Refrigeration/ Air Conditioning Units have 6 Volumes
    Electricity Units have 5 Volumes
    Electricity for HVAC/R Technicians
    Controls Units have 4...
  6. Gundlach No. 853 The Last Drop Suction Gun

    I found this tool helpful. The hose connection is 3/8 inch which fits most drain traps. You can fill with water and it creates pressure to force water through the trap and agitate debris to flush...
  7. Replies
    11
    Views
    1,135

    Isn't it hydrogen gas

    Isn't it hydrogen gas
  8. Replies
    19
    Views
    2,135

    I have the Yellow Jacket branded version of the...

    I have the Yellow Jacket branded version of the DC 1200 that was mated to the Titan manifold. A Titan manifold should work for the AK900.
  9. Replies
    17
    Views
    1,919

    Try Allied Electronics. They are pretty good at...

    Try Allied Electronics. They are pretty good at shipping same day.
  10. Replies
    16
    Views
    4,239

    From what I have been told the Sporlan tool is...

    From what I have been told the Sporlan tool is for TXV gland nuts.
  11. Replies
    16
    Views
    4,239

    337301 Sporlan Valve Wrench Part Number SPOZ57...

    337301

    Sporlan Valve Wrench Part Number SPOZ57



    337311

    Alco Solenoid Valve Spanner Wrench Part Number X11981-1
    Johnstone Supply B14-082
  12. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,146

    If you do small systems there is no advantage....

    If you do small systems there is no advantage. However if you do systems that are wet or very large systems then the TEZ 8 is the way to go as you can monitor oil condition and change oil on the go...
  13. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,146

    You very may well consider adding: Nylog ...

    You very may well consider adding:

    Nylog

    Small bottle of denatured alcohol to clean sensor
  14. Thread: vacum setup

    by MechAcc
    Replies
    102
    Views
    13,146

    Good Job on that kit

    And from the replies you may find that there are things that you may want to add and others that you'll remove.

    Way to XL.
  15. Replies
    39
    Views
    5,963

    The Copeland Scrolls will have a decal stating...

    The Copeland Scrolls will have a decal stating that it has a thermal device.
  16. Replies
    39
    Views
    5,963

    The new scrolls have a thermal relief valve. Once...

    The new scrolls have a thermal relief valve. Once open it does the same thing as a pressure relief allows thermal overload to heat up and shutdown. The overload maybe resetting before the thermal...
  17. Replies
    9
    Views
    1,821

    Itsiceman Remembered taking this photo of...

    Itsiceman

    Remembered taking this photo of Christmas ornament someone gave me. Do think it would make you a good avatar.
  18. Replies
    21
    Views
    3,691

    On Hoshi's monitor the water pressure when it...

    On Hoshi's monitor the water pressure when it goes into harvest. If it drops below 20 psig it may have harvest problems.
  19. Replies
    9
    Views
    1,821

    That is one thing that I didn't like.

    That is one thing that I didn't like.
  20. Replies
    9
    Views
    1,821

    Yellow Jacket uploaded a video of their H2...

    Yellow Jacket uploaded a video of their H2 detector on You Tube

    http://www.youtube.com/watch?v=KDguUryrjPU&feature=plcp
  21. Replies
    21
    Views
    3,691

    If you can get an air wand with a 90 degree tip...

    If you can get an air wand with a 90 degree tip it will be easier.
  22. Replies
    21
    Views
    3,691

    Try Viper Aerosol from Refrigeration...

    Try Viper Aerosol from Refrigeration Technologies. They list list it as safe for all metals. NSF approved for all food process areas. And the best thing there is no pungent odor like other aerosol...
  23. Replies
    44
    Views
    4,360

    Lennox uses the approach method in conjunction...

    Lennox uses the approach method in conjunction with subcooling for charging. Their approach temperatures are below 10 degrees. Check the installation instructions for Lennox AC units.
  24. Replies
    44
    Views
    4,360

    What is the LL approach temperature? Liquid Line...

    What is the LL approach temperature? Liquid Line temperature - Ambient temperature if it is pushing 10 degrees may be a dirty condenser coil. If coil is clean it may be non condensables.
  25. Replies
    44
    Views
    4,360

    Get in the habit of measuring SL and LL...

    Get in the habit of measuring SL and LL temperatures at condensing unit and at evaporator. It will reveal lineset problems.