  1. Replies
    6
    Views
    1,498

    the Alco soleniod manual says for maintenence:...

    the Alco soleniod manual says for maintenence: disassemble and clean yearly or more often if needed.

    But buzzing might be from the coil being loose on the shaft
  2. Thread: Fryer Problems

    by kim
    Replies
    28
    Views
    5,986

    Nobody said that unloaded thermopiles must have...

    Nobody said that unloaded thermopiles must have 150 mV, 100mV loaded.
    Test don't quess.
    Replacing extra parts can be a good thing, but there are lots of restaurants that don't want to spend any...
  3. Replies
    5
    Views
    2,057

    Have seen a couple restaurants with swamp cooler...

    Have seen a couple restaurants with swamp cooler on the kitchen make-up air
  4. Thread: Pitco Frialator

    by kim
    Replies
    4
    Views
    1,457

    I think the last conversion cost me around $25 or...

    I think the last conversion cost me around $25 or $30, buying parts at the store.
    Pitco wanted about $75 for the kit plus shipping.
  5. Thread: Fryer kicking off

    by kim
    Replies
    12
    Views
    3,205

    test before replacing

    Anybody that says change without testing is not right.

    Your job is to inform the costumer, then follow their instructions
    1st find out what is not doing its job.
    2nd jump out a part if...
  6. Replies
    16
    Views
    4,525

    I would change the cap tube I have soldered...

    I would change the cap tube
    I have soldered them. I will not patch them if the bad spot is outside the 100% liquid part of the tube
  7. Thread: southbend

    by kim
    Replies
    4
    Views
    1,456

    southbend

    I have been having gobs of problems with southbend equipment. Most of the problems deal with non ignition on GS and GB series convection ovens. We go out and it is working then we get another call...
  8. Replies
    178
    Views
    4,865

    Blame who you want, but it was AMERICANS that...

    Blame who you want, but it was AMERICANS that decided it was better to save a few buck than to save jobs. Now they have no money to buy those cheap imports and have pushed most of the manufacturing...
  9. Replies
    178
    Views
    4,865

    Funniest thing Ronald Reagon is the GOP hero,...

    Funniest thing Ronald Reagon is the GOP hero, but most of his policies have been ridiculed by the current GOP.

    I bet if you had a poll at a GOP/TP convection, Reagon policies would get very...
  10. Replies
    32
    Views
    1,450

    2 problems exist in the american system 1) non...

    2 problems exist in the american system
    1) non profit companies are perceived as charity and we are too proud to use them.
    2) too many people are worried that somebody else is getting over on them....
  11. Replies
    10
    Views
    2,216

    did you clean the float sensor eyes? I had one...

    did you clean the float sensor eyes?

    I had one acting up like this. The connection @ the soleniod was bad. I always push on the wires @ connectors
  12. Replies
    13
    Views
    1,330

    PLus he has to pay all the tax on that can.

    PLus he has to pay all the tax on that can.
  13. Replies
    15
    Views
    2,456

    First this box is made to run. it should have...

    First this box is made to run. it should have long run cycles. You can't change anything and hope to get immedeate response. you will have to wait for it to stabalize before checking your changes....
  14. Replies
    12
    Views
    1,028

    I think you need to figure out if the low head is...

    I think you need to figure out if the low head is causing the low suction
    or if the low suction is causing low head.

    also
    Remote ice machines are very sensitive to charge. It is hard to...
  15. Thread: headmaster valve

    by kim
    Replies
    13
    Views
    4,227

    not to start any arguements, but it is all a...

    not to start any arguements, but it is all a difference in intended cause and effect. Sometimes it is hard to tell which comes first.

    As long as we agree, headmasters increase head pressure in...
  16. Should work well. Pay back time could be a short...

    Should work well. Pay back time could be a short as 10 or 15 years
  17. Replies
    6
    Views
    609

    Try putting a pan in the bottom of a standard...

    Try putting a pan in the bottom of a standard cooler to drain the evap into. It needs to have an overflow to drain the extra water out of the box.

    If that does not work a small 220V condensate...
  18. Replies
    16
    Views
    2,617

    I had one that the seal on the thermister was...

    I had one that the seal on the thermister was cracked. I would get water in the bulb sometimes. I quess the heat and off time dried it out. so it worked when reset. Found it by soaking the bulb in...
  19. Thread: Fixin' Stupid....

    by kim
    Replies
    7
    Views
    752

    Worked at a store that had problems on the log...

    Worked at a store that had problems on the log everyother night. I could not find a problem.
    Turns out the stock guy turned off the fans while loading the box.
    He was fired
  20. Replies
    21
    Views
    1,751

    I was explaining load lines to the manager and...

    I was explaining load lines to the manager and moved product to leave a small gap between bottles on a Federal display box. He acted like he was listening to me. He hollered at a bus boy. Tells...
  21. Replies
    10
    Views
    943

    I would leave defrost on it just set for 15 min 2...

    I would leave defrost on it just set for 15 min 2 times a day.
    I have seen many beer caves with low temp evaps. I like to change the TXV, but have seen them with low temp TXVs.

    Never seen...
  22. Thread: Manitowoc

    by kim
    Replies
    13
    Views
    1,673

    Had a Mani that was giving us problems. I pulled...

    Had a Mani that was giving us problems. I pulled the recepticle and tightened all the lugs. I tightened all the grounds too. It worked 2 more years, then started acting up again. Boss gave them...
  23. Rack have better run time as well. We put in a...

    Rack have better run time as well.
    We put in a system with 2 5HP compressors on LT and 2 5HP compressor on MT. Only had one condenser. Engineer said it could be up to 60% more efficient than...
  24. Replies
    131
    Views
    14,356

    its the only way to charge quickly easiest way...

    its the only way to charge quickly
    easiest way to find resticted cap tube too

    Of course, if I am topping off, i don't
  25. Thread: Here's one for ya

    by kim
    Replies
    8
    Views
    662

    first off size the valve by the compressor...

    first off size the valve by the compressor capacity.
    second a semi on a small box? I would check the load size. Supply house can do that for you with box dimensions.

    If you getting liquid back...