Search:

Type: Posts; User: vstech

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. the two furnaces on the right are very old and...

    the two furnaces on the right are very old and have no mechanical blowers in the chimney of the furnace.

    the two on the left have blowers that both force the combustion gasses up the chimney, and...
  2. Replies
    7
    Views
    277

    I would call a true service company to come out,...

    I would call a true service company to come out, and actually service the equipment, and not just a "checkup" company out to attempt sales of goodies for their profit.
    I would want a full spectrum...
  3. You have had TWO service companies out and none...

    You have had TWO service companies out and none told you that the pan is NEVER supposed to have water in it...

    Get a REAL service company out to fix the true drain...
  4. Most likely the building itself is leaking, and...

    Most likely the building itself is leaking, and the unbalanced ductwork is leaking causing a pressure change in your apartment... I suggest moving.
  5. The system needs ALL system info checked. Return...

    The system needs ALL system info checked. Return air temp DB& WB, AT THE COIL supply temp AT THE COIL, static pressures, vent register temps, return grille temps, equipment pressures, line temps,...
  6. I would get another opinion on the equipment size...

    I would get another opinion on the equipment size and install specs... Tampa gets both HOT& HUMID, AND YOU WANT A SYSTEM DESIGNED TO PROPERLY AND COMPLETELY CONDITION THE HOME...
    Throwing 5tons at a...
  7. By the third day of sweaters and cold, I'd have...

    By the third day of sweaters and cold, I'd have been on the phone demanding completion. Call the OWNER of the company, and explain what has happened, and see if you can work out an agreement. Or tell...
  8. Replies
    10
    Views
    593

    what you need to do is get the mechanical...

    what you need to do is get the mechanical inspection department in your area involved. they will be able to charge the tech with a misdemeanor and 90 days in jail... unlicensed work is frowned...
  9. Just google "water source heat pump" you will...

    Just google "water source heat pump" you will find many many brands and companies to install them
  10. it really can be a problem. wood can SERIOUSLY...

    it really can be a problem.

    wood can SERIOUSLY swell, and warp, and crack. mold can set into the walls, etc...

    be certain ALL YOUR WINDOWS are open so, the humidity can flow...

    I'm...
  11. Replies
    40
    Views
    1,171

    a 3 ton system will have around 1200 cfm... not...

    a 3 ton system will have around 1200 cfm... not 2200... the more air being moved by the blower, the bigger your ductwork needs to be.

    a 5 ton system would only at most move 2000cfm... where are...
  12. Replies
    7
    Views
    387

    I would want a factory rep to accompany the tech...

    I would want a factory rep to accompany the tech doing the repair... Insist they bring one. It will delay getting the repair done, but it will assure the problem gets resolved.
    Infinity is NOT...
  13. Replies
    43
    Views
    1,137

    It should. Most human beings are comfortable...

    It should.

    Most human beings are comfortable at 76F with a humidity of 50%

    If your humidity is above 50%, you will need a cooler temp to feel comfortable. If you need 63F to feel comfortable,...
  14. Replies
    9
    Views
    386

    If the drain exits outside, you can attach a shop...

    If the drain exits outside, you can attach a shop vac to it and suck out the clog...

    The unit is hanging by CORDS?
  15. Another area to think about is the attic. Open...

    Another area to think about is the attic. Open walls draw crawlspace air into them as attic air is drawn away from either convection or fans. Sealing attic from the living space will help a lot
  16. Replies
    43
    Views
    1,137

    Zoning needed to get even temps, I'm guessing...

    Zoning needed to get even temps, I'm guessing mountain area lots of trees, little need for. AC. Start with general service, get the system operating to spec, then get a quote fir zoning with full...
  17. Replies
    2
    Views
    206

    something is wired wrong, or a computer board has...

    something is wired wrong, or a computer board has failed.

    you are going to need a tech to come out and repair.
  18. he's my buddy, and he is fairly mechanically...

    he's my buddy, and he is fairly mechanically inclined... give him all the recommendations you guys can, and he'll bounce the stuff off me over the phone.

    he keeps bugging me to come up to PA, and...
  19. Replies
    10
    Views
    348

    I have seen PLENTY of houses where the biggest...

    I have seen PLENTY of houses where the biggest problem is bad ductwork. And if it's so bad that 1600 sqft can't be cooled by 3tons, I agree, totally new properly designed ducts are the way to go. ...
  20. Replies
    4
    Views
    201

    I would contact some contractors. You are not...

    I would contact some contractors. You are not going to find any 1.5" vinyl faced insulation anymore... 2" and foil is the standard now. Lowes sell water heater wraps that may be what you are looking...
  21. I just googled PA ENERGY AUDIT and came up with...

    I just googled PA ENERGY AUDIT and came up with several companies.
  22. Look here in the archives for posts from jtrammel...

    Look here in the archives for posts from jtrammel he has a LOT OF GOOD POSTS about manual J load calculations. 4tons 2200 feet, and PA just don't add up unless you have a LOT of glass or some REALLY...
  23. Replies
    7
    Views
    326

    Most scrap yards won't take it unless you are a...

    Most scrap yards won't take it unless you are a licensed contractor due to the copper thefts...

    Craig's may be an option...
  24. if the unit claims 6-7lbs and you have 75feet of...

    if the unit claims 6-7lbs and you have 75feet of line, then you should need an additional 3lbs max. total of 10 lbs, not 15... also, there is no way to tell how much refrigerant is IN the system,...
  25. Replies
    15
    Views
    763

    the infinity equipment controller... ( I just...

    the infinity equipment controller... ( I just cannot call it a thermostat) handles zoning, cfm management, dual fuel, multistage, etc etc etc...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event