    Hi I know this an old thread but i need a driver...

    Hi
    I know this an old thread but i need a driver for XPC 500 ISA board my local vendor is not much help :( any help would be appreciated.

    Thanx
  2. Replies
    281
    Views
    40,877

    Hi ControlTec, Thank you for the reply I am...

    Hi ControlTec,
    Thank you for the reply I am really looking for a PEM1 programers manual and a GCM programers manual.I appreciate the feedback and yes I am using the infocon driver.I can see all the...
  3. Replies
    281
    Views
    40,877

    System 8000

    Can anyone help me out here?
  4. Replies
    281
    Views
    40,877

    Hi everyone, I too have a Network 8000 system...

    Hi everyone,
    I too have a Network 8000 system and need to make changes as the GCM is being replaced with a Jace.I have discovered the PEM's and the MZ11 checked the logic blocks in the GCM with...
  5. Replies
    15
    Views
    4,131

    RE:VMA

    Sit down with a cup of joe and read up on your states and other things like saturation timers etc and then do as proxyking says disable prac and check your propbands.
    GB
  6. Replies
    8
    Views
    623

    RE:JCI

    Like i said contact me via my Email my office is located in Metro Boston Area.
    GB
  7. Replies
    8
    Views
    623

    JCI

    Very experienced wth PMI NCM GPL JCBASIC contact info in my profile
  8. Thread: Honeywell XBS

    by Cal1
    Replies
    3
    Views
    932

    Honeywell XBS

    After a recent power failure we cant log on with any of the user ID's. Is there a default password for XBS 1.4.3? My email addy is in my profile if you can help us that would be great.
  9. Replies
    10
    Views
    973

    You could send the N30 out to be repaired or...

    You could send the N30 out to be repaired or install a Tridium style supervisory FX20 would work just fine for you.
  10. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,437

    Re: Trane Intellipak

    Thank You everyone that did the trick although the DWU was set below the Occupied Heating setpoint they may have been set to closely together.
    In addition patience is the key it took a long time for...
  11. Replies
    5
    Views
    664

    RE: FX SERVER

    I appreciate the help and yes I have been to the FX Supervisory Control training class couple years ago but they did not cover the server setup in great detail. I have looked into the AX...
  12. Thread: JCI GPL

    by Cal1
    Replies
    8
    Views
    1,289

    RE:GPL

    Hi,
    What rev PMI and GPL are you running and on what kinda computer is that XP machine there spanky?
    Shutdown PMI and launch GPL from the FMS/BIN directory. I dont think GPL was ever tested on XP...
  13. Thread: NCM Battery

    by Cal1
    Replies
    9
    Views
    1,597

    The last one i ordered from JCI this past Summer...

    The last one i ordered from JCI this past Summer had a lead time of 8 weeks. Try Ebay buy an old NCM 350 and use the power supply.

    GB
  14. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,437

    RE:Intellipak

    I thank you all for your help I will be on site later this week and will try the setpoint and review the sequence of operation.Its getting cold up here in the NE :) good for business.

    GB
  15. Replies
    5
    Views
    664

    FX Server Questions

    I have a question on the alarm portal.My Niagara Network is all setup three FX's all see each other and the server.I setup a station recipient for each FX pointing to the server but my alarms are not...
  16. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,437

    Hi Mark, Yes I tried that yesterday and the gas...

    Hi Mark,
    Yes I tried that yesterday and the gas heat stages on normally in test mode.The only recent issue with the unit has been the static pressure has been reading hi I am waiting on a altivar...
  17. Thread: Trane Intellipak

    by Cal1
    Replies
    10
    Views
    1,437

    Trane Intellipak

    Hi,
    I have a problem with a Trane Intellipak.The unit wont stage the gas burner on the heat mode enables but the heat does not stage on.All the temperature sensors are reading ok.I put the unit in...
  18. Trending

    Setup M-Trend for the points you need to trend when you want to archive your trend data simply look for the Trenddb.mdb file in the Mdata or active database subdirectory and copy a blank Trenddb.mdb...
  19. Replies
    10
    Views
    933

    Re:DCM

    Go the Niagara route AX of FX especially if your GPL for the DCM's is complex.The programing capability on the AX/FX is vastly superior to the Extended Architecture product line.
    GB
  20. Replies
    8
    Views
    1,053

    M3 Password

    Wow that Sam I must ask thread has legs anyways onto your question try this...


    To reset and set up M-Password:

    1) Select Start > Programs > JCI > M-Password > Config. Leave User Name blank...
  21. Replies
    15
    Views
    1,090

    RE:Return Fan

    Do you have a occupied BD point? Just curious why you are scheduling the fan command itself and not the occupied command.You could also schedule the shutdown command BD 197 if need be. Any chance...
  22. Replies
    15
    Views
    1,090

    RE:Schedule

    What point are you scheduling?
  23. Replies
    24
    Views
    1,187

    Re: NCM

    I will assume you have a NCM 350.Did you check your Novram in the NCM kinda curious as to what port the modem is assigned to.What type code general with OT or NT use NT when you have a modem assigned...
  24. Thread: N-30 Resets

    by Cal1
    Replies
    7
    Views
    478

    Re:N30

    That sounds like a normal power up sequence for the N30. Leave it alone is my advice we have had several fail downloads and go into boot code conditions or worse for no reason at all. Time to upgrade...
  25. Thread: N-30 Resets

    by Cal1
    Replies
    7
    Views
    478

    Re:N30

    Is the DS2 red led on steady or flashing? Does the controller reset continuously?

    GB