  1. Replies
    2
    Views
    92

    Lennox CBX25 blower coils 52.5" for 5 ton, ...

    Lennox CBX25 blower coils 52.5" for 5 ton, shortest Lennox makes
  2. Replies
    4
    Views
    240

    whens the last time you had the unit serviced and...

    whens the last time you had the unit serviced and the charge checked?
  3. take your prices out, not allowed but...

    take your prices out, not allowed but damn........:whistle:

    like previous post get senior tech or another company in there.
  4. Replies
    14
    Views
    1,089

    gotta watch them mexmican lennox units.

    gotta watch them mexmican lennox units.
  5. Replies
    14
    Views
    1,089

    "if you're not bleeding you're not working hard...

    "if you're not bleeding you're not working hard enough" Dad
  6. Replies
    11
    Views
    310

    i don't think it would, there would still be...

    i don't think it would, there would still be water in trap.
  7. Thread: Test IV

    by t527ed
    Replies
    2
    Views
    77

    i was getting it earlier before the site went...

    i was getting it earlier before the site went down.
  8. Replies
    7
    Views
    358

    must have been pretty bad, i was getting...

    must have been pretty bad, i was getting redirected too. started yesterday but thought it must be on my end.

    as long as the site was down it must have taken a while to clean out.:gah:
  9. years ago the factory fittings on many a/c...

    years ago the factory fittings on many a/c systems were compression fittings, if done properly it will last a long time.

    i have a torch so i have never made a repair like that but if it was a...
  10. Replies
    2
    Views
    158

    :ditto: we have installed a couple of the Lennox...

    :ditto: we have installed a couple of the Lennox mini splits, seem as good as anything else........so far.
  11. Replies
    5
    Views
    204

    it was not rated with an orfice, it would use the...

    it was not rated with an orfice, it would use the same size as the 042 unit.

    041 was a SLIGHTLY more efficient unit than the 042.
  12. you guys got in easy......:whistle:

    you guys got in easy......:whistle:
  13. Replies
    10
    Views
    362

    for a commercial application like that i would...

    for a commercial application like that i would rather have a unit i could use at least 2" pleated filters on. i think a mini split would be a headache to keep clean. either rooftop or split system...
  14. Replies
    4
    Views
    231

    oem txv would mount outside of the case on that...

    oem txv would mount outside of the case on that coil. it needs to be insulated to keep from sweating.
  15. drier should be replaced and system evacuated...

    drier should be replaced and system evacuated before starting up new compressor.
  16. when they didn't come back in a few days why...

    when they didn't come back in a few days why didn't you pick up the phone and call them or call someone else to get it finished???
  17. never bothered me when i was younger but i think...

    never bothered me when i was younger but i think over the years it may have caused hearing loss.

    right about the same range as my wife's voice.........:whistle:
  18. Replies
    16
    Views
    587

    stick in whatever size you want, with that old...

    stick in whatever size you want, with that old cap tube coil it won't work right anyway.
  19. i fill mine with expanding foam.

    i fill mine with expanding foam.
  20. the #1 reason we have never installed a 1 pipe...

    the #1 reason we have never installed a 1 pipe condensing furnace. :.02:
  21. Replies
    14
    Views
    496

    air would still blow thru coil the same way, coil...

    air would still blow thru coil the same way, coil is being spun 90deg so lines come out the side instead of front. top of coil is still the top.
  22. Replies
    8
    Views
    327

    thats the way i did it for close to 40 years. ...

    thats the way i did it for close to 40 years.

    with the sucky capacitors on the market today if they test good and look good most times i will leave them as long as they are the right size.
  23. Thread: Cracked Suction

    by t527ed
    Replies
    14
    Views
    449

    me 3

    me 3
  24. Replies
    5
    Views
    251

    call around and get a 2nd opinion. can't tell...

    call around and get a 2nd opinion. can't tell from here if the terminal is leaking but i can tell you if it truly is leaking there is no repair for it.

    also remove your prices, no pricing allowed...
  25. Replies
    10
    Views
    440

    walk-in with a door that opens in?? in over 40...

    walk-in with a door that opens in??
    in over 40 years doing refrigeration i have never seen that.