Search:

Type: Posts; User: Ghlavenka

Search: Search took 0.00 seconds.

  1. Replies
    3
    Views
    1,063

    Here's where I'm at right now: I've got an...

    Here's where I'm at right now:

    I've got an RS-232/TTL converter connected to COM1 of a Windows7 PC. I open DOSbox and map the physical COM1 to the DOSbox COM1. In DOSbox, I run the TDS software...
  2. Replies
    3
    Views
    1,063

    Not a DIY post but...

    I work for a company that repairs electronics. We work on things like laptops, GPS, cellphones etc. which we repair to the component level -- I spend much of my day soldering under a microscope.
    ...
  3. Replies
    8
    Views
    1,141

    Do I need to do more? If the inputs and outputs...

    Do I need to do more? If the inputs and outputs work and I can talk to the processor, what has gone untested? Does the program on the module do anything I can't access by talking directly to the...
  4. Replies
    8
    Views
    1,141

    Well I'm not an authority on any of this stuff...

    Well I'm not an authority on any of this stuff :-) but I thought Ibex was the proprietary protocol and BACnet was the "new" open protocol.

    As far as testing, The Plan is to build some test...
  5. Replies
    8
    Views
    1,141

    The TX653 is going for $ and up on ebay etc. An...

    The TX653 is going for $ and up on ebay etc. An LM324 costs less than a quarter & takes a couple of minutes to swap out. So it still makes sense to do these kind of repairs.

    I also have a bunch...
  6. Replies
    8
    Views
    1,141

    This is not a DIY post!

    This is not a DIY post! But I may not be able to get an answer here anyway.

    I work for a company that does electronic repair work. We fix computers, GPS, cellphones and so on, to the component...