Search:

Type: Posts; User: rkevins

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. remember when your "recovery unit" was a long...

    remember when your "recovery unit" was a long garden hose ran out the back door, then whirlpool came up with a recovery bag you just blew the r12 into the bag.
  2. Replies
    7
    Views
    340

    I replaced one years ago in a Hotpoint the loop...

    I replaced one years ago in a Hotpoint the loop was behind the brake strip you may be able to remove it and braze up the hole
  3. Thread: Poke Salad

    by rkevins
    Replies
    11
    Views
    1,162

    I have eaten it and never thought it was strong,...

    I have eaten it and never thought it was strong, it is best when you scramble eggs in it. It is poison if you don't boil it good just be sure to use young leaves, but I have heard that people fry the...
  4. Replies
    2
    Views
    384

    YJ Gas Retention Valve

    I haven't seen one of these before has anyone used one of these, what exactly are they used for. Yesterday I was working on a 404a icemaker when I hooked up the high side hose I burnt my fingers...
  5. tell him the same thing a plant manager told all...

    tell him the same thing a plant manager told all of us one time " Anyone can be replaced with anyone at any time"
  6. Thread: yaskawa vfd

    by rkevins
    Replies
    10
    Views
    604

    did the display work on the old drive? if so go...

    did the display work on the old drive? if so go to the "modified constants" screen and go through and write down the parameters this will only show what has been modified from factory setting, if not...
  7. Replies
    6
    Views
    598

    glad that wasn't on the test I took

    glad that wasn't on the test I took
  8. Replies
    1
    Views
    235

    PM sent to you I will not be back online until...

    PM sent to you

    I will not be back online until tomorrow night
  9. Replies
    19
    Views
    1,243

    was taught in tech school ( a long time ago) to...

    was taught in tech school ( a long time ago) to put some oil off your nose or drop of ref oil on the end of the cap tube so solder would not stick to end of tube
  10. Thank you

    Thank you
  11. I have also changed my email to a gmail and am...

    I have also changed my email to a gmail and am now listed as a regular guest and can't get into the pro forum can you fix this for me?
  12. Replies
    9
    Views
    683

    how much cleaner are you using, I don't use 6oz...

    how much cleaner are you using, I don't use 6oz like they recommend but use about 2-3 oz pored in then let it fill, and turn the machine off if it starts squealing and let it melt down then turn it...
  13. Replies
    3
    Views
    417

    I sold choretronic about 13 years ago at that...

    I sold choretronic about 13 years ago at that time they were very good equipment, haven't delt with them in some years but chore-time always has built reliable equipment
  14. Replies
    3
    Views
    417

    the same thing you describe has been used in the...

    the same thing you describe has been used in the poultry industry for many years, you could design and build something yourself or check with someone like www.teksupply.com they sell controllers you...
  15. Replies
    4
    Views
    700

    www.trane.com/.../Pdf/.../csc%20-%20ssc%20programm...

    www.trane.com/.../Pdf/.../csc%20-%20ssc%20programming%20guide.pd..
    try this, I hope someone has some more good info I am having problems with some also
  16. Replies
    13
    Views
    1,159

    using gauges on multipal refrigerants

    This will sound like a nubie question but I am just getting back in refrigeration. I have a set of robimair gauges that only show 12 and 22. I know the temp pressure charts on the gauges won't be...
  17. Replies
    16
    Views
    1,627

    our chemical guy droped off some blue leak trace...

    our chemical guy droped off some blue leak trace dye friday, it treats a lot of water. Are they looking for a leak?
  18. Replies
    8
    Views
    906

    Not long ago we had a similar call but found a...

    Not long ago we had a similar call but found a vav that had never been turned on in a 10 year old building, also found one box that a high limit was burned out.
  19. Replies
    19
    Views
    5,869

    We always used uv resources equipment in the air...

    We always used uv resources equipment in the air handlers when I worked in mfg.. as said before keep all wireing you can away from the area, run the wireing in conduit or shield it some way and if...
  20. Ditto for me. We have installed and still service...

    Ditto for me. We have installed and still service 3 SEMCO air handlers with 8 1/2' ERV wheels. They use link belts that are clipped on site

    What do you think of the SEMCO wheels? Before I changed...
  21. Replies
    17
    Views
    2,040

    does anyone have a good link or pdf instructions...

    does anyone have a good link or pdf instructions to cleaning? I have the pdf instruction manuel for the ones I am going to be working on but looking for some more info. Also Do you clean the drain...
  22. Thread: Gross kitchen

    by rkevins
    Replies
    45
    Views
    3,634

    I have seen many bad houses when I did appliance...

    I have seen many bad houses when I did appliance work. fridges stuck to floor with roach crap. If you want to know the realy dirty places make friends with the terminex man the one that came by our...
  23. Replies
    11
    Views
    1,098

    when I was in school we used a comp / condenser...

    when I was in school we used a comp / condenser from a coke box and used scrap pipe to build a Christmas tree, it would frost up and people could not believe it was a self snowing tree
  24. Replies
    4
    Views
    693

    thanks chris I realised afterwords I posted in...

    thanks chris I realised afterwords I posted in the wrong place
  25. Replies
    4
    Views
    693

    chasing duct work blockage

    I work in a hospital, a few days ago we had a interesting coincidence we had to test a fire door later in the day we had a comlaint of no cooling in some areas. we found we were not getting air past...
Results 1 to 25 of 79