02-22-2013, 04:36 PM
Thread: Rental
by TAC Service- Replies
- 24
- Views
- 1,803
If there is a hole in the backyard fence I know...
If there is a hole in the backyard fence I know where to get the blocks to fix it.
-
02-01-2013, 01:07 PM
Thread: VAV Reheat System
by TAC Service- Replies
- 12
- Views
- 670
Thanks for the response, It looks like it will...
Thanks for the response, It looks like it will work if you set it up as pressure dependent and get away
from the velocity controller. I was mainly curious if anyone has ever seen an installation... -
01-31-2013, 09:48 AM
Thread: VAV Reheat System
by TAC Service- Replies
- 12
- Views
- 670
VAV Reheat System
We just started servicing a building that has two large VAV package units and a hot water boiler with pump all located on the roof, this system is very common for the area. Downstairs in the suite...
-
12-01-2012, 06:33 PM
- Replies
- 1
- Views
- 377
The balancing valve should be installed in the...
The balancing valve should be installed in the return line on the system side of the by-pass line. That way the coil or its by-pass line will never use more water than its designed for.
-
11-06-2012, 12:20 AM
Thread: Liquid Line temp question
by TAC Service- Replies
- 5
- Views
- 551
Your amp draw will be under FLA because the head...
Your amp draw will be under FLA because the head pressure is low. Your expansion valves are hunting because you don't have the required 100 psig MOP. The suction is less that 100 psig from the...
-
10-30-2012, 12:30 AM
Thread: Things that make you go...WTF...
by TAC Service- Replies
- 10
- Views
- 1,899
The pitch of the swamper matches the slope on the...
The pitch of the swamper matches the slope on the mountain.
-
07-07-2012, 03:19 PM
Thread: Quality Craftmanship
by TAC Service- Replies
- 4
- Views
- 1,184
Quality Craftmanship
Went on a call today and found the last tenant removed their AC unit when they moved. The new tenant felt thet needed some air so they had one of our fellow craftsman borrow some air from another...
-
06-07-2012, 11:39 PM
Thread: Proper condenser location. Haha
by TAC Service- Replies
- 13
- Views
- 1,824
Cut a hole in the floor and you have a perimeter...
Cut a hole in the floor and you have a perimeter heater for the porch.
-
11-14-2011, 10:22 PM
Thread: can I post a wall of shame to be?
by TAC Service- Replies
- 8
- Views
- 1,938
When I send my duck to work he refuses to wear...
When I send my duck to work he refuses to wear boots.
-
11-14-2011, 10:17 PM
- Replies
- 44
- Views
- 6,775
The pump will never wear out.
The pump will never wear out.
-
10-30-2011, 11:18 PM
Thread: what code?
by TAC Service- Replies
- 15
- Views
- 2,733
They really need to paint the unistrut.
They really need to paint the unistrut.
-
10-27-2011, 12:25 AM
Thread: getting cold in the northwest!
by TAC Service- Replies
- 9
- Views
- 1,323
Someone installed their ice machine outside.
Someone installed their ice machine outside.
-
10-27-2011, 12:23 AM
Thread: Creative engineering
by TAC Service- Replies
- 13
- Views
- 2,096
Who gets to clean the spray tree & nozzles:gah: ?
Who gets to clean the spray tree & nozzles:gah: ?
-
10-11-2011, 02:25 PM
Thread: Going HVAC at 55 years old
by TAC Service- Replies
- 73
- Views
- 7,773
One of the big problems is he will be the helper...
One of the big problems is he will be the helper for the next several years.
That can be physically challenging as well as mentally challenging to take orders from someone half his age. -
09-21-2011, 12:52 PM
- Replies
- 10
- Views
- 1,823
If the air conditioning thing doesn't work out...
If the air conditioning thing doesn't work out you can always go into
movie making. -
09-14-2011, 10:45 PM
Thread: Light Commercial Automation System?
by TAC Service- Replies
- 12
- Views
- 1,119
www.solidyne.com (http://www.solidyne.com)
www.solidyne.com
-
09-11-2011, 07:01 PM
Thread: Question on PID loop
by TAC Service- Replies
- 25
- Views
- 1,661
OSA temperature was commonly used in commercial...
OSA temperature was commonly used in commercial buildings with alot of solar exposure (glass) to bring on the refrigeration system. The load of a glass building will be effected more by OSA. The...
-
08-14-2011, 12:19 PM
Thread: for lack of a better pace
by TAC Service- Replies
- 9
- Views
- 1,242
Over the years there have been several attempts...
Over the years there have been several attempts to use high pressure duct systems in commercial office buildings (4" to 8"wc). The advantages were smaller duct (cheaper) and less attic space...
-
08-14-2011, 12:03 PM
Thread: Landis & Gyr (Powers) System 600
by TAC Service- Replies
- 4
- Views
- 1,252
Thank You.
Thank You.
-
08-12-2011, 01:08 PM
Thread: Landis & Gyr (Powers) System 600
by TAC Service- Replies
- 4
- Views
- 1,252
Landis & Gyr (Powers) System 600
I just inherited this building with a small system 600 panel. Its primarly used for start-stop and some elementary control functions. The owner wants to keep it because its currently working. There...
-
07-20-2011, 12:17 AM
Thread: OA Intakes
by TAC Service- Replies
- 8
- Views
- 1,065
We have a customer that installed screen material...
We have a customer that installed screen material (like you find in your screen door) over the fresh air intakes, its very effective but has to be cleaned regularly.
-
07-20-2011, 12:11 AM
- Replies
- 6
- Views
- 590
When you have a receiver in the system it is no...
When you have a receiver in the system it is no longer a critical charge unit. A proper charge is having the pick-up tube in the receiver covered in liquid under all operating conditions. Most...
-
07-19-2011, 11:43 PM
Thread: Frozen Dampers
by TAC Service- Replies
- 1
- Views
- 296
Frozen Dampers
We have had issues while freeing up frozen economizer dampers on large air handlers with odors in the building from the lubricant we use. Liquid wrench seems to work the best but stinks the most. ...
-
06-05-2011, 09:40 PM
Thread: carrier 15 ton split
by TAC Service- Replies
- 5
- Views
- 589
You will need to pressurize it, locate and repair...
You will need to pressurize it, locate and repair the leak(s). Tell your boss to calm down, when new equipment fails on start-up there will be a labor and material allowance from the factory. It...
-
05-19-2011, 10:56 AM
Thread: R-438a
by TAC Service- Replies
- 0
- Views
- 700
R-438a
Has anybody used Dupont ISCEON M099 (R-438a) refrigerant as a direct replacement for R-22 yet ? If you have, what size system and how did it work ?
Thanks