06-14-2011, 09:29 PM
Thread: Trane Rtu
by indoorcomfrtsl- Replies
- 14
- Views
- 1,038
Trane Rtu
I am working with a Trane Rtu M/N YCH150C4LOAB..S/N L06104. Customer wants to replace the zone sensor with a programmable thermostat.The existing sensor is a BAYSEN008B. I have no wiring diagram so I...
-
06-14-2011, 08:51 PM
Thread: Water source heat pump
by indoorcomfrtsl- Replies
- 9
- Views
- 754
I added 1# R22 which brought the superheat closer...
I added 1# R22 which brought the superheat closer to 12. My discharge pressure fell inline with the entering cond water temp. i am having the maintenance clean the evap coil as it does have some...
-
06-13-2011, 09:04 PM
Thread: Water source heat pump
by indoorcomfrtsl- Replies
- 9
- Views
- 754
going back tues. going to check the water flow...
going back tues. going to check the water flow thru condenser then perhaps add a little refrigerant. the evap almost seems to be starving a bit.
-
06-12-2011, 10:43 PM
Thread: Water source heat pump
by indoorcomfrtsl- Replies
- 9
- Views
- 754
I found out comdenser water temp rise should be...
I found out comdenser water temp rise should be 10 to 14..so i think with high subcooling and high superheat it may be a txv or metering device as it looks like a fixed orfice.
-
06-11-2011, 11:06 PM
Thread: Water source heat pump
by indoorcomfrtsl- Replies
- 9
- Views
- 754
Water source heat pump
I have a McQuay heat pump M/N CCH120AETS. The compressor seems to intermitently shut down and not restart until the power is reset. When i went out I found the following>>>suction 70# discharge...
-
03-23-2011, 09:41 PM
Thread: Walk in freezer
by indoorcomfrtsl- Replies
- 22
- Views
- 1,528
I have previously blown out the condenser coil...
I have previously blown out the condenser coil but it probably could use more. I charged it as a liquid. yes the hot gas condensate evap. I am just not sure what proper operating temp pressures...
-
03-23-2011, 09:27 PM
Thread: Walk in freezer
by indoorcomfrtsl- Replies
- 22
- Views
- 1,528
70 to 75. the discharge air of the condenser...
70 to 75. the discharge air of the condenser seems to be recycling because of the low ceiling tiles.
-
03-23-2011, 09:13 PM
Thread: Walk in freezer
by indoorcomfrtsl- Replies
- 22
- Views
- 1,528
on top of the case
on top of the case
-
03-23-2011, 08:31 PM
Thread: Walk in freezer
by indoorcomfrtsl- Replies
- 22
- Views
- 1,528
Walk in freezer
I have a Polar Pak system that had a refrigerant leak and went flat. The leak was on the bottom of the 3/8 loop that sits in the drain pan. After repairing it I started to charge the system. It...
-
02-03-2011, 07:58 AM
Thread: Leibert refrigerant charge
by indoorcomfrtsl- Replies
- 4
- Views
- 660
Yes it has a sight glass. It is also 14 degrees...
Yes it has a sight glass. It is also 14 degrees outside. On amother note it seems someone put a 6" pulley on the blower motor. I can't get the amps right so I am wondering if the pulley size is wrong.
-
02-02-2011, 09:48 PM
Thread: Leibert refrigerant charge
by indoorcomfrtsl- Replies
- 4
- Views
- 660
Leibert refrigerant charge
I have a Challenger 3000 M/N Bu06---CAM (middle part of # missing) The condenser M/N is CSF083-P. Is there any information on the factory refrigerant charge? When the hot gas by pass valve is...
-
11-14-2010, 09:41 PM
Thread: Fulton Boiler lockout code
by indoorcomfrtsl- Replies
- 1
- Views
- 997
Fulton Boiler lockout code
I am working on a Fulton Vantage Boiler. M/N VTG-3000. The boiler has been locking out requiring a manual restart. The code on the seimens control says -Fan contactor Fan contactor is off. It is...
-
05-29-2010, 06:14 PM
Thread: Boiler Heat exchanger corrosion
by indoorcomfrtsl- Replies
- 7
- Views
- 1,239
The heat exchanger has a leak at the...
The heat exchanger has a leak at the header,allowing domestic hot water to enter the combustion side. Once the burner would light it would flash the water to vapor causing the calcium left in the...
-
05-29-2010, 06:09 PM
- Replies
- 5
- Views
- 671
If you look inside a ball valve you will see that...
If you look inside a ball valve you will see that the size is smaller. You can order full port valves for minimal restriction.
-
05-21-2010, 11:00 PM
Thread: Boiler Heat exchanger corrosion
by indoorcomfrtsl- Replies
- 7
- Views
- 1,239
Its the worst I have seen also..I brushed it out...
Its the worst I have seen also..I brushed it out and then hosed it out and used CLR to clean..then found the leak.
-
05-19-2010, 11:15 PM
Thread: Boiler Heat exchanger corrosion
by indoorcomfrtsl- Replies
- 7
- Views
- 1,239
Heat exchanger corrosion
http://i804.photobucket.com/albums/yy322/stevesexplorer/jaylot/Jaylot-1.jpg
I also found a water leak at the top header of the exchanger. -
05-17-2010, 08:30 PM
Thread: Boiler Heat exchanger corrosion
by indoorcomfrtsl- Replies
- 7
- Views
- 1,239
Boiler Heat exchanger corrosion
I have a Munchkin Boiler M/N 399VWHASMEP. Inside the heat exchanger I found an excessive amount of white corrosion. I will try and put a picture up.
I believe it is electrylosis. How do I prove it... -
03-31-2010, 12:34 AM
Thread: Storage Tanks
by indoorcomfrtsl- Replies
- 11
- Views
- 761
The heat exchanger is a steam tube bundle,do not...
The heat exchanger is a steam tube bundle,do not know the capacity ,yet. I installed tees on the pumps to get pressures. I did find out engineers design stogage tanks with the assumption that at 800...
-
03-26-2010, 09:21 PM
Thread: Storage Tanks
by indoorcomfrtsl- Replies
- 11
- Views
- 761
Storage Tanks
I have 3- 3300 gallon domestic hot water storage tanks that i am trying to heat and maintain temps of 140. I am trying to estimate how many btu's it will need. I am using 3 steam boilers rated at 4...
-
12-02-2009, 09:39 PM
Thread: Uline Ice Maker
by indoorcomfrtsl- Replies
- 3
- Views
- 481
Uline Ice Maker
Does anyone have a link or info on a under the counter ice maker? It's an Uline M/N ULN75R-00. I am pretty sure its a discontinued model so any info would be great. I have 3 of them that are not...
-
11-26-2009, 11:16 PM
Thread: Refrigerants
by indoorcomfrtsl- Replies
- 7
- Views
- 430
I see where I made my mistake with the 408 and Hp...
I see where I made my mistake with the 408 and Hp 80
-
11-26-2009, 11:13 PM
Thread: Refrigerants
by indoorcomfrtsl- Replies
- 7
- Views
- 430
I am not sure it is low yet. I am working on two...
I am not sure it is low yet. I am working on two different systems. The one that I think is low also has 2 of 4 evap fan motors failed. I can't check the charge until the motors are replaced. I found...
-
11-26-2009, 10:48 PM
Thread: Refrigerants
by indoorcomfrtsl- Replies
- 7
- Views
- 430
I will add 408A. I was looking at a alternative...
I will add 408A. I was looking at a alternative refrigerants chart and saw that R402 and R408 looked similiar.After looking at the composition of refrigerant blends chart am I correct in seeing that...
-
11-26-2009, 09:44 PM
Thread: Refrigerants
by indoorcomfrtsl- Replies
- 7
- Views
- 430
Refrigerants
If a system has been charged with 408A can I add HP80 if the charge is low?
If the compressor is marked 408A and the txv is marked 502 is this a problem or are they compatable? -
11-04-2009, 08:48 PM
Thread: Motor Grease
by indoorcomfrtsl- Replies
- 19
- Views
- 1,900
Motor Grease
I have a US Motors motor M/N H60P2 B S. It is a 60 hp motor that is used as our chilled water pump. It runs 24/7 and is classified as a hostile duty motor.
It has grease fittings but I am not sure...