Search:
Type: Posts; User: frostyac
Search: Search took 0.02 seconds; generated 45 minute(s) ago.
-
06-10-2011, 08:08 AM
Thread: Help on Birch egg cooler
by frostyac- Replies
- 1
- Views
- 431
Help on Birch egg cooler
Need to know average low side pressure on a R-22 egg cooler on a chicken farm. room temp needs to run at 65 .
-
06-09-2011, 07:05 PM
Thread: Help on Birch egg cooler.
by frostyac- Replies
- 2
- Views
- 605
Help on Birch egg cooler.
My friend works on birch egg coolers on chicken farms. But he is out of town He installed one yesterday that he put a compressor in. He called me to see if I would check on it for him The egg owner...
-
06-09-2011, 05:32 PM
Thread: Heip on Birch Egg cooler.
by frostyac- Replies
- 2
- Views
- 318
Heip on Birch Egg cooler.
My friend is out of town , He works on egg coolers on chicken farms he calls me to go see about one he installed yesterday The owner called and saidT it froze up last night THE installer said the...
-
05-26-2011, 05:46 PM
Thread: cps micron gauge
by frostyac- Replies
- 2
- Views
- 261
cps micron gauge
Is the cps vg 200 a good buy?
-
www. hvacsuperpro.com
www. hvacsuperpro.com
-
A bondiing joint compound to replace brazing ...
A bondiing joint compound to replace brazing copper tubing. Some thing new.
-
super pro
What is your coments on this new super pro ?
-
06-08-2010, 07:05 PM
Thread: armstrong txv
by frostyac- Replies
- 11
- Views
- 1,252
OUT DOOR EXPANSION VALVE # 78L19
OUT DOOR EXPANSION VALVE # 78L19
-
06-08-2010, 06:22 PM
Thread: armstrong txv
by frostyac- Replies
- 11
- Views
- 1,252
Just got home from installing a 2 ton txv on a...
Just got home from installing a 2 ton txv on a armstrong cond. unit got it at cc dickson
no prob. Do you need a number ?? -
03-05-2009, 08:11 AM
Thread: s.p. issue
by frostyac- Replies
- 1
- Views
- 285
s.p. issue
2 1/2 TON HP. [ PACK ] out side on slab. supply 14 "pipe run up out side wall 8 ft. elbowed in attic run 15 ft. to dist. box 20 x20. 8 run outs 4 - 8 " flex runs 15 ft. 4- 6 " runs 8 to 12 ft. TL= ...
-
07-13-2008, 11:51 AM
- Replies
- 106
- Views
- 5,448
Ac Man
When you walk into a drug store in 1950 and wonder how it makes the air cold , and now 58 years later iam still wondering. ha ha
-
06-09-2008, 09:20 PM
Thread: cond fan runs backwards
by frostyac- Replies
- 4
- Views
- 347
cond fan runs backwards
I have a 2 ton goodman, Cond fans starts runs for a while , then starts running backwards . [ changed cap still run backwards ] seen this a few times with lighting strikes , seen no bad weather in...
-
08-28-2007, 01:26 PM
Thread: Liquid line temperature too high? 125F?
by frostyac- Replies
- 6
- Views
- 653
hot line
Check cond. fan, and clean cond. hp to high
-
Member
Capacitor with no info. How do know what MFD to use?
-
08-17-2007, 05:31 PM
Thread: low voltage issue?
by frostyac- Replies
- 10
- Views
- 662
I had a contactor awhile back had 24 v on coil...
I had a contactor awhile back had 24 v on coil but it would not go in.had extra wire on t stat change wire work fine.
-
01-29-2006, 05:42 PM
Thread: Goodman HP ?
by frostyac- Replies
- 3
- Views
- 657
Yes it is. 45 degree out side it should do the...
Yes it is. 45 degree out side it should do the job with out heat strips, got me in the wondering mode. Home owner says when it drops to around 40 F out side it will not heat the house with out...
-
01-29-2006, 05:08 PM
Thread: Goodman HP ?
by frostyac- Replies
- 3
- Views
- 657
Working on a 1 1/2 ton Goodman heat pump.My prob....
Working on a 1 1/2 ton Goodman heat pump.My prob. is can not get but 120 degree on vapor line to inside coil .I jumperd the rev. valve blocked off cond fan got head pressure up to 300 lb. SP = 70 LB....
-
12-19-2005, 02:15 PM
Thread: defrost control for heat pump
by frostyac- Replies
- 4
- Views
- 1,321
I used a new sensor , the old sensor was a bulb...
I used a new sensor , the old sensor was a bulb sensor Ranco E-15 The new sensor is a NTC type.I moved sensor to a well where the old bulb was in.I will go back later to see if this worked.
... -
12-19-2005, 10:54 AM
Thread: defrost control for heat pump
by frostyac- Replies
- 4
- Views
- 1,321
It will go into defrost when you jumpe the pins,...
It will go into defrost when you jumpe the pins, but it will not on its own.The old sensor was in a well,do i need to put it back in the well on the coil? May be bad board.
-
12-19-2005, 10:33 AM
Thread: defrost control for heat pump
by frostyac- Replies
- 4
- Views
- 1,321
I have replaced a Ranco E-15 defrost control to a...
I have replaced a Ranco E-15 defrost control to a ICM315C CONTROL.I can not get it to defrost. I did not insulate the sensor, this is a thermistor sensor, do i need to?
-
11-30-2005, 05:24 PM
Thread: defrost control ???
by frostyac- Replies
- 2
- Views
- 688
I replaced a defrost board on a old heat pump 20...
I replaced a defrost board on a old heat pump 20 yr. old donot know the brand name.It had a ranco E15 DEFROST control.Can not get it to manualy defrost.I jumped out sensor pins and shorted defrost...
-
09-08-2005, 05:28 PM
Thread: many many issues with Goodman! HELP!
by frostyac- Replies
- 19
- Views
- 1,433
The burners may need cleaning.
The burners may need cleaning.
-
09-03-2005, 03:41 PM
Thread: What ton is air handler
by frostyac- Replies
- 7
- Views
- 875
Does that mean yepper for yes ?
Does that mean yepper for yes ?
-
09-03-2005, 03:37 PM
Thread: What ton is air handler
by frostyac- Replies
- 7
- Views
- 875
Is that greek for dont no ?
Is that greek for dont no ?
-
09-03-2005, 02:31 PM
Thread: What ton is air handler
by frostyac- Replies
- 7
- Views
- 875
What is the tonage on this rheem air handler ? #...
What is the tonage on this rheem air handler ? # RBHA - 24 -J20SFAA. 5 TON ?
Results 1 to 25 of 36