    Ditto ! Joey, just wait till you get Old and...

    Ditto ! Joey, just wait till you get Old and Tired. The floor get really hard after the big 5 Ohhhh.

    Really !

    I have 2 or 3 of the Lifetime Folding tables and they are all labeled "Not Your's...
  2. Unless you have a very unique system (or I have...

    Unless you have a very unique system (or I have lost my mind) ALL the points in a Point Group exist (in the "Points") on some device.

    I must be missing something here, sorry.
  3. Gaseous Anomaly, Brief "how To' assuming you...

    Gaseous Anomaly,

    Brief "how To' assuming you have sufficient access to the system:
    1. Expand Station/Administration/Graphics Templates, open Graphics templates folder.
    2. Copy...
  4. Maybe you could just simply map the points from...

    Maybe you could just simply map the points from the actual "Points List" directly to a PX file. Saves a step the way I see it. JMO
  5. Thread: hvacpro

    by Cagey57
    Replies
    14
    Views
    1,020

    I would suggest using HAVC-Pro 8.08 with the...

    I would suggest using HAVC-Pro 8.08 with the "B"-Patch.

    Another option is the B & B Electronics 485SD9TB Converter if you have a 9pin Serial port. I have always used it with out an external power...
  6. Replies
    7
    Views
    464

    Tigger, We have a project in Cherry Creek that...

    Tigger,
    We have a project in Cherry Creek that just got one retrofitted (replaced an old 19DX ?) a few month ago. PM me and maybe we can get you down there to have a look.

    In the past few years...
  7. Replies
    21
    Views
    1,168

    TheControlsFreak has it almost dead on. Been...

    TheControlsFreak has it almost dead on.

    Been doing controls specifically for almost 20 years. My DMM is a Fluke 115 (with the real leads not those skinny peices of junk), had a 116 but it is...
  8. Replies
    3
    Views
    151

    mechmike2, Default IP address for NET1 (right...

    mechmike2,
    Default IP address for NET1 (right hand jack) should be 192.168.1.149

    Be careful connecting to an FX with MH WB version. The new FX-60 is likely licensed at Ax 3.7 or Ax 3.8 and there...
  9. Thread: N2 Wiring?

    by Cagey57
    Replies
    6
    Views
    279

    fisha, s2sam is one of our resident experts on...

    fisha,
    s2sam is one of our resident experts on RS485 ! (as always sam, thanks for your knowledge)

    Go here http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2 and look for "Metasys...
  10. Replies
    13
    Views
    394

    Oops, my bad you may have to write at priority 8...

    Oops, my bad you may have to write at priority 8 since it's an AI. You'll figure it out.
  11. Replies
    13
    Views
    394

    Add a Numeric Writable, assign it to AI-2, name...

    Add a Numeric Writable, assign it to AI-2, name it "WCADJ1". Then set the Fallback to "0". Then copy/paste it into the points sheet for every VMA you want to have that feature on. If your not sure...
  12. Replies
    11
    Views
    463

    techservices, To answer your question, "I would...

    techservices,
    To answer your question, "I would be really suprised if it did "! (short answer No!)

    Suggest you use 18/3 Shielded cable and make the connection for the UNT on the same terminals as...
  13. Replies
    8
    Views
    724

    K2000, As mechdorn said it is very regional. We...

    K2000,
    As mechdorn said it is very regional. We do have a "Budget Estimate" based on a per Box amount. We typically run our own 24VAC power wiring ourselves but that is also due to prevailing...
  14. Replies
    22
    Views
    821

    54885488, I tried numerous time to get it to...

    54885488,
    I tried numerous time to get it to work. As far as I know it (HVAC-Pro) is so timing specific that it wont work over ethernet.

    PM s2sam or steves4 with your question. They are pretty...
  15. Replies
    22
    Views
    821

    54885488, We have used the Moxa Nport devices on...

    54885488,
    We have used the Moxa Nport devices on both Companion (nearly Identical to a Facilitator) and NCM's (OT Mode) with good success. The only isues are getting the serial side (RS-232)...
  16. Replies
    10
    Views
    587

    T87F, I suggest you load FX-WB 1.2, 2.0 so you...

    T87F,
    I suggest you load FX-WB 1.2, 2.0 so you don't have problems with that FX-40.
    You should be able to download it from the FX-Pro users forum (Connected Community) if you have access.

    I...
  17. Replies
    1
    Views
    238

    leakcheck, You may already know this but there...

    leakcheck,
    You may already know this but there were/are issues with an TEC210x series T-stat if it is the last device on the bus/trunk.

    If I remember right you need a 220 Ohm EOL resistor and a...
  18. go here...

    go here http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2

    Search for lit-6363081, see page 30 for a picture.

    That should clear up your problem.
  19. Check the AI Input jumpers on the lower left...

    Check the AI Input jumpers on the lower left corner of the device. They can be set for 0-10VDC, 0-2VDC or Temp (bottom Sw down, top Sw up if I remember right). It's printed on the label above the...
  20. Dumb question here, did you check the Input DIP...

    Dumb question here, did you check the Input DIP switches ?

    If the siwitches are correct, simply re-assign your input from AI-3 to AI-6 and see what happens.

    Ohm the sensors, 1000ohms at 70 Deg...
  21. Replies
    3
    Views
    610

    Basparky, see attached from HVAC-Pro Help.

    Basparky,
    see attached from HVAC-Pro Help.
  22. Replies
    23
    Views
    1,173

    54885488, Can you post a pic of the...

    54885488,
    Can you post a pic of the "Facilitator" you have ?
    Your comment about (FA?)-UNT111-1 implies that you have HAVC-Pro, what version ?
    Maybe start a thread in the Pro Controls Forum and we...
  23. Replies
    23
    Views
    1,173

    The configuration 54885488 has is with the FX-60...

    The configuration 54885488 has is with the FX-60 or facilitator located in the center of the Bus. Each side/segment can have 5000' developed length and 50 devices per side/segment.

    Pretty sure...
  24. Replies
    8
    Views
    503

    alliedtech12887, Put an email in your profile....

    alliedtech12887,

    Put an email in your profile. Good things could come your way !

    HVAC-Pro "8.08B" is a patch and not a full distribution release.
  25. Replies
    8
    Views
    503

    2 things to look for: 1. Are the VMA's at...

    2 things to look for:
    1. Are the VMA's at HVAC-Pro version 8.08b ? If not they really should be upgraded to 8.08b !
    2. Check the COV values in the VMA's. I usually change them to 1.0 for temps and...