Search:

Type: Posts; User: kontrolphreak

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    7
    Views
    1,893

    Null modem cable and Hyper-Terminal. kontrol...

    Null modem cable and Hyper-Terminal.

    kontrol out
  2. Thread: Osiyo

    by kontrolphreak
    Replies
    11
    Views
    1,009

    Hopefully he actually retired and left this...

    Hopefully he actually retired and left this horrid life behind him.
    Best of luck to him if he did.

    kontrol out
  3. Replies
    4
    Views
    211

    Could you provide a 55" monitor so I can read...

    Could you provide a 55" monitor so I can read your screen shot?

    kontrol out
  4. I know SiteBuilder (ALC) managed BBMD lists in...

    I know SiteBuilder (ALC) managed BBMD lists in their routers, don't know if i-Vu does as well. If not you probably have to configure one of the routers and the i-Vu to be a BBMD if you are going to...
  5. I have worked on JCI sites with diplicate BACnet...

    I have worked on JCI sites with diplicate BACnet device instances and thankfully was using WebCTRL where I could reference the controller via network addresd and MAC otherwise I would have been in...
  6. Replies
    1
    Views
    167

    I never work offline with RC-Studio, just saying....

    I never work offline with RC-Studio, just saying.

    kontrol out
  7. Replies
    28
    Views
    1,342

    If it is all ALC hardware WebCTRL automatically...

    If it is all ALC hardware WebCTRL automatically configures the BBMD lists in each LGR if required. ALC used to have a stand alone app to configure BBMD lists in their routers, not sure if this is...
  8. BACnet interoperability depends on what version...

    BACnet interoperability depends on what version of WebCTRL you are running. Display points are great for viewing and manual interaction of third party BACnet objects, if you want to bring it into the...
  9. Replies
    3
    Views
    236

    No. kontrol out

    No.

    kontrol out
  10. Replies
    5
    Views
    244

    From my failing memory inputs where assigned by...

    From my failing memory inputs where assigned by clicking on the image of the controller in the bottom right hand section of the VisualLogic page. Data transfer was done with WEDS and REDS, schedules...
  11. Or install a BACnet touchscreen to interface with...

    Or install a BACnet touchscreen to interface with the system (some controllers come with displays built in now days).

    kontrol out
  12. There are a few freeware applications that will...

    There are a few freeware applications that will connect to BACnet system, although most if not all require a BACnet/IP connection. There is even a Android app that connects via a a wireless IP...
  13. Replies
    2
    Views
    264

    http://www.solidyne.com/#!pnt1/c1cq9 Not sure...

    http://www.solidyne.com/#!pnt1/c1cq9

    Not sure about the fruit phone requirement.

    kontrol out
  14. Replies
    12
    Views
    588

    Chipkin's BACnet For Field Technicians has...

    Chipkin's BACnet For Field Technicians has Wireshark primer towards the end of the book:

    http://www.chipkin.com/files/pdf/Bacnet%20For%20Field%20Technicians.pdf

    kontrol out
  15. Replies
    3
    Views
    301

    One of my favorite systems to work with....

    One of my favorite systems to work with. Generally use Visio to make my graphics background and subscribe to their graphics package for all the parts, pieces and animations.

    RCS2 isn't bad (great...
  16. Replies
    28
    Views
    1,342

    Hyper-Terminal and a USB converter. kontrol out

    Hyper-Terminal and a USB converter.

    kontrol out
  17. Replies
    13
    Views
    625

    I've only used the Temco Modbus version, the...

    I've only used the Temco Modbus version, the BACnet version is new, Felxstats work as advertised (although without KMC software they are configurable only, with software you can write custom logic.)...
  18. Replies
    13
    Views
    625

    http://www.temcocontrols.com/products/thermostats/...

    http://www.temcocontrols.com/products/thermostats/tstat8.htm
    http://www.solidyne.com/#!pnt1/c1cq9
    http://www.kele.com/network-and-wireless/flexstat.aspx
    https://www.exactlogic.com/BACNet
    ...
  19. Replies
    41
    Views
    1,615

    LOL kontrol out

    LOL

    kontrol out
  20. Too bad, the ability to dynamically create,...

    Too bad, the ability to dynamically create, delete and configure objects using a different manufacturer's front end on another manufacturer's controllers is where interoperability truly begins.
    ...
  21. Replies
    12
    Views
    701

    Interesting that some companies lock you out of...

    Interesting that some companies lock you out of viewing their logic, all the manufacturers I have mainly worked with (Reliable Controls, Delta Controls, ALC, Andover, Alerton) all allow you not only...
  22. Replies
    7
    Views
    363

    66247365 kontrol out

    66247365

    kontrol out
  23. Replies
    11
    Views
    1,078

    If you want some more up to date reading American...

    If you want some more up to date reading American Technical Publishing has a great series of books (HVAC-Talks own lonboy was a co-author of one in the series).
    ...
  24. Because when replacing a Alerton controller with...

    Because when replacing a Alerton controller with another brands and wanting to use the existing Alerton graphic on the front end, I have no way of creating a input or output that uses zero as an...
  25. Replies
    11
    Views
    1,078

    Chris is a she. I don't know ASI support, but do...

    Chris is a she. I don't know ASI support, but do know Chris and she is a top notch controls professional with a tonne of real world experience not just a bunch of book knowledge.

    kontrol out
  26. Most systems start at 1, the only one I have come...

    Most systems start at 1, the only one I have come across that starts at 0 is Alerton and it makes life difficult.

    kontrol out
  27. Replies
    11
    Views
    1,078

    You should do well, your mechanical background...

    You should do well, your mechanical background we'll help immensely. Learn the basics and fundamentals thoroughly and build on that, don't go diving into the deep end of the pool right away.

    ASI...
  28. Replies
    25
    Views
    5,807

    :hijacked: kontrol out

    :hijacked:

    kontrol out
  29. Replies
    25
    Views
    5,807

    If Workbench can register as a foreign device I...

    If Workbench can register as a foreign device I don't see why not.

    kontrol out
  30. Replies
    5
    Views
    2,226

    Viewing and editing the DSM attributes shouldn't...

    Viewing and editing the DSM attributes shouldn't be a problem if you have access to ORCAview, if you need to change and or create graphics ORCAview will need to have a USB key with Illustrator...
  31. Delta did make a applications for setting network...

    Delta did make a applications for setting network configurations in OEM branded controllers. Other settings will require ORCAview or ORCAweb, without these your out of luck.

    kontrol out
  32. Replies
    4
    Views
    292

    Welcome, you'll find they critters here to be...

    Welcome, you'll find they critters here to be friendly and knowledgeable.

    kontrol out
  33. What are the BACnet/IP networks addressed as? ...

    What are the BACnet/IP networks addressed as?

    kontrol out
  34. Replies
    4
    Views
    309

    Firmware is software specific (firmware in...

    Firmware is software specific (firmware in controller must match ORCAview version to get full functionality). USB keys will run any version of ORCAview up to 3.4.

    kontrol out
  35. Replies
    4
    Views
    309

    As far as I know all Delta USB keys are backwards...

    As far as I know all Delta USB keys are backwards (and forwards) compatible, you just need 3.30 ORCAview or Flash loader and 3.33 firmware if you already have 3.33 software.

    kontrol out
  36. Object ID is what the controller and programming...

    Object ID is what the controller and programming use to interact with the object, it is usually preceded by the Device ID unless it is a local object in the device - DevID|ObjType|ObjNo#. A object...
  37. Man I sure do miss paragraphs, I guess their not...

    Man I sure do miss paragraphs, I guess their not needed in code so their not needed in day to day communication.

    kontrol out
  38. STOP YELLING! KONTROL OUT

    STOP YELLING!

    KONTROL OUT
  39. Rigid averaging install like a regular duct...

    Rigid averaging install like a regular duct sensor, no need to cut any additional openings other than the one for the 1/4" (3/8" hole) probe. Best results are installing it vertically in the center...
  40. http://cdn.meme.am/instances/400x/36533028.jpg ...

    http://cdn.meme.am/instances/400x/36533028.jpg

    kontrol out
  41. Dealer site is for super fly dealers only. ...

    Dealer site is for super fly dealers only.

    http://rightontvhd.com/wp-content/uploads/2014/08/SUPER-FLY.jpg

    kontrol out
  42. Look into rigid averaging. kontrol out

    Look into rigid averaging.

    kontrol out
  43. Replies
    6
    Views
    435

    You're going to need to do some port forwarding...

    You're going to need to do some port forwarding from your external IP in your router to the relays internal IP to go from the www to the relay.

    kontrol out
  44. Replies
    9
    Views
    751

    Just installed two of these using Modbus...

    Just installed two of these using Modbus integration which was the easy part, not the most friendly devices to physically install and calibrate.

    kontrol out
  45. Is there a manual with all the REPL...

    Is there a manual with all the REPL commands/scripts?
    Being able to download all the objects in the controller as .vsc file would be great as well as each individual objects properties as files....
  46. If the Lochnivar supports priority arrays send it...

    If the Lochnivar supports priority arrays send it at a higher level, start at 7 and if that doesn't work try 5, 4, or 3. I would not use 6, 2, or 1 as they have set applications (some devices won't...
  47. Replies
    1
    Views
    245

    IIRC Visual Logic and Visio need to be loaded in...

    IIRC Visual Logic and Visio need to be loaded in a specific order. If Visio was already installed Visual Logic probably had to be installed prior to Visio for it to show up. Try uninstalling Visio...
  48. Also like the details and info in the device...

    Also like the details and info in the device object, added property number would be beneficial.

    kontrol out
  49. I would like to see the ability to view and...

    I would like to see the ability to view and configure BACnet schedules.
    How about the ability to dynamically create/delete objects as well as configure them.
    The ability to write to properties of...
  50. Only time I used a Fieldserver on a boiler it was...

    Only time I used a Fieldserver on a boiler it was not a good solution, device could only either send data to the built in touchscreen or the EMCS system, not both concurrently. Even though it had...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365