  1. Replies
    4
    Views
    306

    You mean use one of the two outputs as it would...

    You mean use one of the two outputs as it would be of varying length? But how about the other output is that not the one pulsed to "turn the other way"? Don't have it to try until Monday. Interesting...
  2. Replies
    4
    Views
    306

    Learning

    Yes I also learned it that way. Which is generally good enough. I have used them a fair amount. I just had occasion to need a PWM output. And looked at the docs and realized the information is pretty...
  3. Replies
    4
    Views
    306

    FX-PCT advanced

    Curious if anyone has documenataion/help on programming the PCG10xx controllers that has more data than the PCT help files on advanced programming?
  4. Replies
    15
    Views
    1,564

    N2 is rs485 but the zone bus has only one +com...

    N2 is rs485 but the zone bus has only one +com line and a common shown on the schematic. I assume the "Cable Pro box (AS-CBLPRO-?, eBay?) or the newer Converter Pro box (AS-CVTPRO-?)" converts the...
  5. Replies
    20
    Views
    1,321

    sure

    Fine. Whatever you say. I simply remember more details. Or realize I came across wrong. And seek to correct that. I dont expect anything. I ask only for what is freely given. And I have twice done...
  6. Replies
    20
    Views
    1,321

    answers

    Yes this is what I am studying now while waiting on the wisdom to straighten me out. Bacnet/IP from the Niagara workstation into the Metasys workstation via WAN. Failing that from the Jace's to a JCI...
  7. Replies
    20
    Views
    1,321

    answers

    No they want it the other way around. My opinion was not asked. It's the Metasys they want as the front end. All or most of the other sites are JCI.
  8. Replies
    20
    Views
    1,321

    Answers

    Hi GregF
    Thanks for the reply. I am not trying to combine field level networks. I did not read your post before replying this morning to the others. I get jumped when I come here. Must be my face....
  9. Replies
    20
    Views
    1,321

    answers

    I am not trying to change vendors. Nor to take someones work. Or bash any company or technology. I already have and have had the responsibility for the system in question. It is not a school but a 5...
  10. Replies
    20
    Views
    1,321

    Ok

    Ok. I did not ask how to do it. I knew better. I was just looking for opinions. Guess I got that. I never said it was a good idea. Since when does that matter?
  11. Replies
    20
    Views
    1,321

    tough one?

    This is a tough one? Or I am just asking the wrong question? I work with so many different types of controls in the last few years. Seems like every property has their own. I have been caring for the...
  12. Replies
    20
    Views
    1,321

    jace501 > metasys

    Hi
    I am wondering how one would approach integrating a site with multiple jace 501's with bacnet and lonworks feild devices all connected with an ethernet switch to a pc running R2 and a browser....
  13. Replies
    0
    Views
    290

    Tracker upgrade suggestions

    Hi guys
    I am aware there are a lot of Tracker threads in the archives. But I am also aware of how quickly things change lately. I have a building with about 16 VariTrac ccp's X13650529-01. I say...
  14. Replies
    11
    Views
    809

    whoops

    Heat mode, Room temp 67, Summit BCU.
  15. Replies
    11
    Views
    809

    Thanks

    Hi guys
    Sorry for the delayed response. The minimum cfm idea is not it since I tried using a higher minimum and it did not work. It is on a summit BCU. I dont recall the terminal numbers but there...
  16. Replies
    11
    Views
    809

    yes I am sure

    Yes I am sure it is not cycling on high limit. The power/signal stops at the board itself. There are no fixed resistors either. I thought of that. Worked before. Dont now. I go back when I have a...
  17. Replies
    11
    Views
    809

    There are no discharge air sensors. On any of...

    There are no discharge air sensors. On any of them.
  18. Replies
    11
    Views
    809

    Varitrane heat problem

    Hi
    Single duct electric heat VAV. The heat cycles on and off. The setup is identical to others that do not show the problem. Board # is x13690252-07 comm4, Voltage, flow, safteties etc all ok. Any...
  19. Replies
    16
    Views
    975

    A VFD can run more than one motor at the same...

    A VFD can run more than one motor at the same time.
  20. Replies
    16
    Views
    975

    GT Jets is correct. Assuming the pumps are in...

    GT Jets is correct. Assuming the pumps are in parallel they have check valves on the discharges. Either of the pumps would have to produce a pressure differential equal to or greater than the...
  21. Replies
    10
    Views
    474

    service pack? I did not think of that. Had not...

    service pack? I did not think of that. Had not needed to up till now.
  22. Replies
    10
    Views
    474

    You dont actually get a choice I think. Rover...

    You dont actually get a choice I think. Rover detects the BCU when you attempt to change modes and gives you a choice, Server connected or GTFO.
  23. Replies
    10
    Views
    474

    The Summit panel is less than two years old. I am...

    The Summit panel is less than two years old. I am unsure of the exact version. BMTX is all I remember and dont have my notes right now. I have Rover 6 all buttons active. And what you describe is the...
  24. Replies
    19
    Views
    2,549

    Thanks

    Well I can usually buy 1 or 2 of almost anything. It is the complete packages and fair pricing and access to support like upgrades that I need.
  25. Replies
    10
    Views
    474

    I had not tried using the BCU network variables....

    I had not tried using the BCU network variables. It would be a pain as you say figuring which is which. But I had assumed they would be even more "guarded". I like Trane stuff. Install a lot of it....