Search:

Type: Posts; User: wanttosee

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Lights???

    by wanttosee
    Replies
    24
    Views
    785

    the 919 snake light is great. After a few years...

    the 919 snake light is great. After a few years of use the neck gets weak and the head will droop after setting it in place.
  2. Thread: john stabile

    by wanttosee
    Replies
    3
    Views
    222

    beenthere

    you are a knowledgeable person, have a beer and enjoy.
  3. Thread: U V W terms

    by wanttosee
    Replies
    9
    Views
    467

    Then ignore the UVW. The compressor terminals are...

    Then ignore the UVW. The compressor terminals are double marked for different types of power.
  4. Thread: U V W terms

    by wanttosee
    Replies
    9
    Views
    467

    Sure, slap it in there, hook it up and pray the...

    Sure, slap it in there, hook it up and pray the compressor isn't 3 phase.

    Or plug in the model number and be sure.
  5. Replies
    5
    Views
    392

    Just for reference, when your heat pump goes into...

    Just for reference, when your heat pump goes into a defrost cycle it should trigger the aux heaters to come online. With the colder temperatures you're going to have more defrost cycles.

    What is...
  6. forgive my ignorance but is teflon tape not...

    forgive my ignorance but is teflon tape not supposed to be used on gas fittings? If so, then what is?
  7. Replies
    10
    Views
    710

    This is what I was taught as well. The foaming...

    This is what I was taught as well. The foaming action was caused from the lye in the cleaner dissolving aluminum. Hence why you must rinse all of it off and you end up with a shiny coil.
  8. Replies
    10
    Views
    710

    #3D is great for getting love bugs off...

    #3D is great for getting love bugs off windshields and bumpers. It works really good for dissolving nicotine tar from coils and surfaces. It's ok for general cleaning and unsticking organic debris.
    ...
  9. Replies
    43
    Views
    2,277

    Locally the NATE test costs $330. To me that is...

    Locally the NATE test costs $330. To me that is expensive so I've been researching the benefit it can bring to me. Of the people I've discussed this with, not one person outside the hvac industry...
  10. Is the RA pickup point close to the floor? We...

    Is the RA pickup point close to the floor?

    We have a few customers who need pan tabs added multiple times per year. They all have multiple cats and they all have the AH on a stand in a closet.
  11. Replies
    15
    Views
    999

    The ones shown in the picture are Siemens...

    The ones shown in the picture are Siemens BQ2B060. Ive only seen Siemens ones, never GE. They do operate as regular breakers do and not just service disconnects.
  12. Ive seen zip ties, foil tape and copper wire used...

    Ive seen zip ties, foil tape and copper wire used to hold the bulb on.

    On some rheem systems where the bulb was mounted externally I would foil tape the bulb to the suction line and roll the...
  13. We use acetone. Cleans really well.

    We use acetone. Cleans really well.
  14. Replies
    28
    Views
    1,106

    Poll: Just an fyi, a rheem 14ajm will give a 14.5-16...

    Just an fyi, a rheem 14ajm will give a 14.5-16 SEER rating depending on which evap coil you go with.
  15. Replies
    7
    Views
    513

    with 20 degrees of superheat i'd expect the...

    with 20 degrees of superheat i'd expect the accumulator to be empty of any liquid.

    Am i missing something basic?
  16. Thread: Manufacturer

    by wanttosee
    Replies
    3
    Views
    333

    Concord, change both the o to zeros and research

    Concord, change both the o to zeros and research
  17. Thread: two for one

    by wanttosee
    Replies
    22
    Views
    4,487

    You're my hero.

    You're my hero.
  18. Replies
    11
    Views
    2,239

    no, they'd have a green backing for 30 amp. ...

    no, they'd have a green backing for 30 amp. those are 20 amp switches.
  19. Replies
    31
    Views
    2,330

    Looking at the GSK9 wiring diagram I don't see...

    Looking at the GSK9 wiring diagram I don't see anything that would lead me to believe that when the call for heat comes from the thermostat, the blower will start running. I've been doing this for 4...
  20. Replies
    27
    Views
    3,617

    Quite true, though technically #12 wire is rated...

    Quite true, though technically #12 wire is rated at 25 amps according to 310.16 and so the wire is still suitable for the aplcation. I still contend that the real problem is the improper voltage and...
  21. Replies
    27
    Views
    3,617

    Check out 210.23. An individual branch circuit...

    Check out 210.23. An individual branch circuit can supply any single load up to 100% of the overcurrent protection value. Since I doubt the freezer is cord and plug connected and supplies other...
  22. Replies
    27
    Views
    3,617

    Not true, #12 is limited to 20 amps in all...

    Not true, #12 is limited to 20 amps in all situations except for specific conductor applications. A/Cs, motors, welders, capacitor banksare all exceptions to the 20 amp rule. Office lighting and...
  23. Thread: Iphone 5

    by wanttosee
    Replies
    19
    Views
    1,860

    Offered without comment other than NSFW ...

    Offered without comment other than NSFW



    Well I can't get youtube to embed, twice. So I guess this is offered without content.

    Hopefully the link at least works. ...
  24. Thread: all-thread

    by wanttosee
    Replies
    1
    Views
    839

    If it's recessed, I would add a sleeve so you can...

    If it's recessed, I would add a sleeve so you can lock a nut to the anchor.
  25. Replies
    27
    Views
    3,617

    If you're drawing 20.1 amps at 208 volts that...

    If you're drawing 20.1 amps at 208 volts that equates to 4180 va. You'd need a 4.2kva buck boost transformer rating at a minimum to do that properly. A .5kva sized bb transformer would accomplish...
Results 1 to 25 of 163
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event