Search:

Type: Posts; User: Bsmith816

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    590
    Views
    100,955

    Every experienced tech should know that a...

    Every experienced tech should know that a customer will lie to your face no matter what. I don't care if it's an 80year old lady, I am not getting screwed and will get paid. If a customer gets over...
  2. Replies
    16
    Views
    1,506

    Are you sure you have a 208/230 moto? Just a...

    Are you sure you have a 208/230 moto? Just a question
  3. Replies
    36
    Views
    3,945

    Definetly DIY.. If you can't figure this problem...

    Definetly DIY.. If you can't figure this problem out you are definetly not a service tech....
  4. Thread: Installers

    by Bsmith816
    Replies
    8
    Views
    601

    That's what I try to get through to the new guys...

    That's what I try to get through to the new guys who come work for us. If you don't know something just stop right there and ask. It's better to be sure then to proceed and make a costly mistake that...
  5. Replies
    6
    Views
    633

    I would go down on the tstat and not got for...

    I would go down on the tstat and not got for Icomfort wifi since its a communicating tstat and you are not getting communicating equipment. That tstat should ony be used with Lennox signature series...
  6. Replies
    13
    Views
    1,088

    On a leak search if it's on the condensing unit...

    On a leak search if it's on the condensing unit My electronic picks it up every time. Plus you can usually see oil spots. If I don't find leak outside I remove the front door of acoil and spray the...
  7. You should be able to handle the warranty BUT...

    You should be able to handle the warranty BUT from experience why would you want to. I know you want to be the hero and the good guy but once you touch that unit and work on it, that now becomes your...
  8. My company sets me up with 10-15 calls per day....

    My company sets me up with 10-15 calls per day. In the summer time I will start at 6am and work until 11pm. Monday-Saturday then only work half,day on Sunday. That is only 3 months out of the year
  9. Replies
    17
    Views
    1,359

    I agree with you. No point in doing it unless you...

    I agree with you. No point in doing it unless you can do it right. The customer is paying for a service and which you cannot provide accurate readings unless the temp is above 55. Some say to use a...
  10. Replies
    27
    Views
    6,105

    That is exactly why we refuse to install off...

    That is exactly why we refuse to install off breed brands. That's why off breed units cost a lot less. Sure you make a higher profit because the cost of the equipment costs less but look at the...
  11. Replies
    4
    Views
    681

    The contractor that told you to replace the...

    The contractor that told you to replace the entire unit is the right one. Since the unit sat open to atmosphere it is contaminated with moisture. I'm sure putting a new line set in would work but the...
  12. Replies
    57
    Views
    3,974

    Did u put a manometer on to see what the...

    Did u put a manometer on to see what the differential pressure is? Checking for debris doesn't mean anything
  13. Replies
    57
    Views
    3,974

    What is your microamp signal like Core_d is...

    What is your microamp signal like Core_d is asking?? need to check it at sensor and where it connects on board.. Never clean with sandpaper, believe it or not it can ruin it.is your pressure switch...
  14. Replies
    17
    Views
    1,466

    I usually bid it $500 less than a new unit...even...

    I usually bid it $500 less than a new unit...even if it's under warranty
  15. Replies
    8
    Views
    1,145

    I personally have been in that situation before....

    I personally have been in that situation before. One night last winter on a cold night I had an elderly couple have a g61mpv furnace blower motor fail. I didn't have a variable speed motor with me so...
  16. Replies
    19
    Views
    1,732

    Electricity is not a guessiing game. People that...

    Electricity is not a guessiing game. People that don't understand it should leave it alone
  17. Replies
    8
    Views
    777

    Inducing pump???? Hmmmm definely know what he's...

    Inducing pump???? Hmmmm definely know what he's doing
  18. My family has a company in Hvac company in KC and...

    My family has a company in Hvac company in KC and we are a premiere Lennox dealer. I would be willing to help you take care of your problem if you would like. You can email me at
    <Email addresses...
  19. The filter is not the problem. If he has been...

    The filter is not the problem. If he has been using the same one for years he has a separate issue. The furnace needs at least a 1/2 hs motor and u need to set the speed to medium high for heat. The...
  20. If I was you I would have a technician wire that...

    If I was you I would have a technician wire that IAQ for you. If you don't understand dehumidification and electricity that tstat will be very difficult for you to install. If you don't jumper that...
  21. Energy rater LA. I agree "dido"

    Energy rater LA. I agree "dido"
  22. Replies
    28
    Views
    2,262

    I love how they are giving you " lifetime ...

    I love how they are giving you " lifetime workmanship warranty" that there is a load of bs
  23. Replies
    17
    Views
    1,321

    Take it as your first Mis diagnose lesson. Always...

    Take it as your first Mis diagnose lesson. Always triple check your self and know the sequence of operation and where and when should voltage be
  24. I myself always run evap coil dain and furnace...

    I myself always run evap coil dain and furnace drain completely separate. Lennox changes their condensate trap every month I think
  25. They are not like batteries that get weak and you...

    They are not like batteries that get weak and you have to change them. A capacitor should stay the same forever. Remember the old capacitors that they used to put in units that had PCB in them, you...