05-16-2013, 11:25 PM
Thread: NRP vacuum pumps
by caddy- Replies
- 8
- Views
- 264
I have used my 6 cfm pump on 500 ton chillers...
I have used my 6 cfm pump on 500 ton chillers without any issues. Just pull with 1/2" hose. It's pulled them down with no prob.
-
I still use my veto LC I bought bought 4-5 yrs...
I still use my veto LC I bought bought 4-5 yrs ago. It is still in good condition other than a couple of zippers lost. Recently I picked up a Klein backpack to use during pms. Got it due to veto...
-
05-15-2013, 10:14 PM
Thread: Who gets stuck being on call
by caddy- Replies
- 53
- Views
- 2,698
At our shop A/C techs on call about every 3...
At our shop A/C techs on call about every 3 months. Us chiller techs every 5 wks. And controls tech weekly, last I checked. The A/C tech carries the on call phone and has a backup on call tech. ...
-
05-09-2013, 11:12 PM
Thread: Testo 550 clamp probe
by caddy- Replies
- 2
- Views
- 122
10 4 will order replacement tomorrow
10 4 will order replacement tomorrow
-
05-09-2013, 10:07 PM
Thread: Testo 550 clamp probe
by caddy- Replies
- 2
- Views
- 122
Testo 550 clamp probe
Today while starting up a comp on a chiller I noticed one of my pipe clamp probes did not register. I tried on both sides but no luck. I noticed one of the pins broke. Is there a way to repair or...
-
07-04-2012, 02:19 PM
Thread: Condensate pump for 7.5 ton
by caddy- Replies
- 10
- Views
- 757
There is no place nearby and unit is installed in...
There is no place nearby and unit is installed in center of warehouse. There is no sewer or drain in building due to its just a parts storage. GC wants to pump condensate up to roof.
-
07-04-2012, 02:02 PM
Thread: Condensate pump for 7.5 ton
by caddy- Replies
- 10
- Views
- 757
No sink or janitors closet nearby. Only option...
No sink or janitors closet nearby. Only option is pump up to roof.
-
07-04-2012, 01:22 PM
Thread: Condensate pump for 7.5 ton
by caddy- Replies
- 10
- Views
- 757
Condensate pump for 7.5 ton
Has anyone used a condensate pump for a commercial split system? Unit is 7.5 tons and there is no where to run PVC drain lines. Only solution is to go to roof 20' high.
-
01-22-2012, 07:14 PM
Thread: The wait is over....
by caddy- Replies
- 558
- Views
- 40,252
Wait was too long
I waited last year for anticipated release of 11. Could not wait any longer, so sometime in end of Nov I just bout me some testo 550. So far I am happy with product. It was a step up from digimon.
-
09-30-2011, 08:11 PM
Thread: Vacuum Guage
by caddy- Replies
- 28
- Views
- 1,793
I use yellow jacket 6075
I use yellow jacket 6075
-
09-15-2011, 09:39 PM
Thread: vacuum pump
by caddy- Replies
- 22
- Views
- 1,521
That's why I use 1/2" hose. Can pull a 500+ton...
That's why I use 1/2" hose. Can pull a 500+ton chiller down faster than the pumps we carry in our trucks.
-
09-13-2011, 06:56 PM
Thread: vacuum pump
by caddy- Replies
- 22
- Views
- 1,521
Welch pumps are what we use for large chillers...
Welch pumps are what we use for large chillers when we want to pull fast. Check out eBay for some used ones.
-
09-13-2011, 06:51 PM
- Replies
- 57
- Views
- 4,866
I have the LC. I would recommend a collapsable...
I have the LC. I would recommend a collapsable hand truck to haul around. By the time you load bag you are looking at close to 50# so the hand truck is a back and shoulder saver if you have to walk...
-
09-13-2011, 06:43 PM
Thread: H10PM Question
by caddy- Replies
- 4
- Views
- 503
Have both h10 and h10pm. Can't beat reliability...
Have both h10 and h10pm. Can't beat reliability of both. Now I just use the pm since I don't have to pull a cord.
-
09-13-2011, 06:40 PM
Thread: meter questions
by caddy- Replies
- 18
- Views
- 1,669
Fluke 902 and 179
Fluke 902 and 179
-
09-11-2011, 08:30 PM
Thread: Refrigerant Tank Heater
by caddy- Replies
- 22
- Views
- 3,234
I have a tank heater I picked up at grainger, it...
I have a tank heater I picked up at grainger, it has adjustable temp knob. But I have used on occasion a handheld mapp gas torch I picked up at lowes. I use blanket when I have 120v nearby and...
-
Should of gotten a FLUKE:D
Should of gotten a FLUKE:D
-
That's what the meter is for
That's what the meter is for
-
08-16-2010, 11:23 PM
Thread: Installing CSHA Comp. On Trane Intellipak
by caddy- Replies
- 11
- Views
- 744
I have used utektek and then have gone over it...
I have used utektek and then have gone over it with 15%.
-
08-12-2010, 06:28 PM
Thread: Carrier line set question Puron
by caddy- Replies
- 4
- Views
- 496
Thanks for feedback. I will change liquid to 3/8".
Thanks for feedback. I will change liquid to 3/8".
-
08-09-2010, 10:41 PM
Thread: Carrier line set question Puron
by caddy- Replies
- 4
- Views
- 496
Carrier line set question Puron
Question in installing 5ton commercial split systems with Puron Refrigerant. The line set to one unit is approx 80' and the other about 30'. The unit connections are 3/8 and 7/8. I was hanging 1...
-
06-10-2010, 10:36 PM
Thread: 30GTN...T055
by caddy- Replies
- 23
- Views
- 1,656
I have had several GTN's with the OEM ice cube...
I have had several GTN's with the OEM ice cube relays failing and giving the code to55. They are for the compressor feedback signal and if i remember right are 5vdc through contacts. I swapped out...
-
04-01-2010, 10:00 PM
Thread: 19DH guide vane rebuild
by caddy- Replies
- 12
- Views
- 800
Chiller Tex? What happened to stuttering wes?
Chiller Tex? What happened to stuttering wes?
-
I bought mine LC on the net. And yes these bags...
I bought mine LC on the net. And yes these bags are good. My old bags would last about a yr before they either tore or no longer stood upright. I have had this bag over a yr and still going strong....
-
06-23-2009, 12:06 AM
Thread: Design a HVAC Specific Veto Pro Pac Here
by caddy- Replies
- 275
- Views
- 24,764
I just bought mine through ebay, it showed it was...
I just bought mine through ebay, it showed it was the last one. Plus I got to use a ebay coupon which gave me a discount. I will be watching for its arrival.