Search:

Type: Posts; User: captinsano

Page 1 of 15 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    48
    Views
    2,552

    If you can get a job doing supermarkets...

    If you can get a job doing supermarkets everything else is easy after that!
  2. Replies
    2
    Views
    1,722

    Doesnt Mr.Bunky have them he has everything else!

    Doesnt Mr.Bunky have them he has everything else!
  3. Replies
    21
    Views
    2,720

    Their number is (803)939-1914 ask for Mike...

    Their number is (803)939-1914 ask for Mike Driscoll!
  4. Replies
    21
    Views
    2,720

    Yes I did the service manager is a genius,and you...

    Yes I did the service manager is a genius,and you can work all the 80 hour weeks your heart desires all good high end stores no garbage just markets,Publix is there main customer,along w/Harris...
  5. Replies
    12
    Views
    4,174

    Buddy had to take it said it was technical in...

    Buddy had to take it said it was technical in nature!
  6. Replies
    12
    Views
    4,174

    was not required of me!

    was not required of me!
  7. Replies
    21
    Views
    2,720

    Excell is a great company hope you like to...

    Excell is a great company hope you like to work,alot!
  8. Depends on what your workin on,Hustler is an...

    Depends on what your workin on,Hustler is an excellent choice like I said it depends on what your workin on!
  9. Thread: R134a

    by captinsano
    Replies
    7
    Views
    751

    It was also a replacement for r-500 wich was also...

    It was also a replacement for r-500 wich was also used by Westinghouse/McQuay for r-500 it was a capacity reduction and a gear set change!
  10. Replies
    5
    Views
    686

    Get a copeland electrical book from a supply...

    Get a copeland electrical book from a supply house it will tell you how to wire it for sure.Make sure you trim the oil charge after you get it running,they use a compressor shop in Georgia to rebuild...
  11. Replies
    6
    Views
    809

    Check the discharge superheat if it falls below...

    Check the discharge superheat if it falls below 22 degrees the oil will disapear wich means you have something flooding back or if its hot gas defrost you have something flooding the rack in...
  12. Replies
    8
    Views
    779

    Check the superheat on everthing attatched to it...

    Check the superheat on everthing attatched to it that suction pressure is way to low you can maintain icecream @ 15 psi r-22 if al txvs are set right you should be able to float that rack if its all...
  13. Replies
    5
    Views
    1,257

    I believe on that compressor your oil pressure...

    I believe on that compressor your oil pressure reg valve is in the lube box on the right hand side of impeller may try tweaking it a bit,I have some bulletins I can dig out.
  14. Replies
    10
    Views
    3,491

    CEK

    McQuay wont sell you the kit they have to put it in yank the machine!You and the customer will be better off!
  15. Replies
    6
    Views
    544

    Veto Pro Packs

    Trane parts in Columbia S.C. has Vetos in stock!
  16. Replies
    5
    Views
    758

    Bit confusing if it in fact has a motor protector...

    Bit confusing if it in fact has a motor protector on the compressor and you changed the module and it is still occuring jump the module and put a good ohm meter w/ a hi resistance scale on the...
  17. Replies
    20
    Views
    2,021

    If you quit smoking just dont take up the full...

    If you quit smoking just dont take up the full time drinking lots of it in this trade from the daily stresses!
  18. call excell Refrigeration in Lantana they do...

    call excell Refrigeration in Lantana they do supermarkets install &service
  19. Replies
    5
    Views
    2,406

    get a carbonator pump and motor from grainger I...

    get a carbonator pump and motor from grainger I use it to pump 7-10 gallons of oil quickly you can also pump liquid refrigerant with it.
  20. Replies
    3
    Views
    577

    if ti is hot gas defrost that could be youre...

    if ti is hot gas defrost that could be youre culprit if it doesnt have cpc on it put the different circuit through defrost and check it could be getting floodback after defrost
  21. Replies
    12
    Views
    2,399

    I put one on something from 1968 a few years ago...

    I put one on something from 1968 a few years ago same same!
  22. Replies
    14
    Views
    2,658

    there is a method you can use to ballance the...

    there is a method you can use to ballance the units and it helps if you have a vibration meter to find out wich of the multiple wheels is the worst as a starting point to begin ballancing the...
  23. Replies
    14
    Views
    2,658

    if you have a cheap vibration meter you can...

    if you have a cheap vibration meter you can ballance units easily.
    I would guess these have multiple wheels if so I can help you out.
  24. put a 502 or 404 powerhead on the valve,when I...

    put a 502 or 404 powerhead on the valve,when I did markets I carried 2 different body size powerheads for 502 and you could use em on 404 also!While you got it pumped downe puul the guts apart and...
  25. Replies
    5
    Views
    3,296

    thats not that uncommon clamp or screw it to the...

    thats not that uncommon clamp or screw it to the curb whatever they require!
Results 1 to 25 of 368
Page 1 of 15 1 2 3 4
Comfortech Show Promo Image