10-10-2012, 12:42 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
Thanks again Maxburn!
Thanks again Maxburn!
-
10-10-2012, 12:29 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
no I guess I have forgotten that step, where do I...
no I guess I have forgotten that step, where do I go to do that?
-
10-09-2012, 01:20 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
Once I have edited a .eik file and repacked it...
Once I have edited a .eik file and repacked it into an .fb I then converted it to a.equipment file and copied the files into the /m68 and /programs directories, however it does not update the view on...
-
09-28-2012, 01:26 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
i got it, i was typing the filename with the .fb...
i got it, i was typing the filename with the .fb at the end and that was messing things up. thanks for all the help MaxBurn!
-
09-28-2012, 12:45 PM
Thread: adding BACnet points to Automated Logic
by bwhlar- Replies
- 15
- Views
- 2,108
that is what i was trying, but once I hit u to...
that is what i was trying, but once I hit u to unpack the .fb file goes empty and there is no .eik file to be found anywhere. i am really glad to have made a backup the first time i tried.
-
09-28-2012, 12:31 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
I have the fbpack tool but I am having trouble...
I have the fbpack tool but I am having trouble unpacking and locating the .eik out of the .fb file. can anyone help me with this step?
-
09-28-2012, 12:29 PM
Thread: adding BACnet points to Automated Logic
by bwhlar- Replies
- 15
- Views
- 2,108
I have the fbpack tool but I am having trouble...
I have the fbpack tool but I am having trouble unpacking and locating the .eik out of the .fb file. can anyone help me with this step?
-
09-14-2012, 03:19 PM
- Replies
- 11
- Views
- 756
If I have a server with the N2 dialers in place,...
If I have a server with the N2 dialers in place, is it possible to remote connect to the server in order to do remote programming for a site?
-
09-13-2012, 05:53 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
Do you know if there is a version of eikon that...
Do you know if there is a version of eikon that will run on a 64bit windows 7 pc?
-
09-13-2012, 04:01 PM
Thread: WebCTRL edits applied to .equipment file?
by bwhlar- Replies
- 14
- Views
- 1,152
Eikon/FBPack tool
Does anyone know where to get a copy of the FBPack tool to convert a .fb to a .eik in order to edit it with th eikon?