Search:

Type: Posts; User: howardgt

Search: Search took 0.00 seconds.

  1. Replies
    11
    Views
    2,567

    Food service techs only please

    I work for a company that does food equipment and refrigeration only. We do hot and cold side. My question is : How do you food service only guys keep from losing work to HVAC/refrigeration/plumbing...
  2. Replies
    34
    Views
    3,216

    Thermocouple tester

    Anyone know where I can get a screw in thermocouple tester?
  3. Replies
    9
    Views
    2,728

    www.cpsohio.com

    www.cpsohio.com
  4. Replies
    7
    Views
    2,487

    I absolutely despise fryers. I think they are the...

    I absolutely despise fryers. I think they are the worst thing by far to work on in a kitchen. I especially hate the gas ones; or the ones that are very over-engineered super hi-tech. I mean, it's a...
  5. Call Bakers Pride 800-431-2745

    Call Bakers Pride 800-431-2745
  6. Replies
    5
    Views
    2,076

    Great info! Thanks!

    Great info! Thanks!
  7. Replies
    5
    Views
    2,076

    Fryer cleaning

    How do you guys recommend cleaning fryers? A few of our customers have fryers that are so bad that sometimes I wanna tell them "call someone else, I'm not doing it". I'm not being a baby, I know...
  8. Replies
    3
    Views
    1,735

    Contact Star Mfg. They bought Lang. 1-800-264-7827

    Contact Star Mfg. They bought Lang. 1-800-264-7827
  9. Thread: Fryer

    by howardgt
    Replies
    9
    Views
    2,054

    Fryer

    Customer said unit was leaking "a little oil".
  10. Replies
    16
    Views
    3,963

    It is nat. I have played with the GP. It is now...

    It is nat. I have played with the GP. It is now set at 3.5 WC. I've gone higher and lower, same result. The orifices are 42, which I verified through M-M. What's so aggravating is that this ignition...
  11. Replies
    16
    Views
    3,963

    The unit is operational. Just have to cycle it...

    The unit is operational. Just have to cycle it when turning it on. Once lit, it's fine. We are scheduled to go back there when we get in some non-related parts.
  12. Replies
    16
    Views
    3,963

    Igniter was replaced with module, so was ignition...

    Igniter was replaced with module, so was ignition cable. I've covered the basics.
  13. Replies
    16
    Views
    3,963

    Module was just replaced. Same result. I have...

    Module was just replaced. Same result. I have another tech thats gonna go out with me on this unit when we get the new blower belt in. I just hope another set of eyes will help. If I am missing...
  14. Replies
    16
    Views
    3,963

    Thanks for info. The unit is 7 months old. The...

    Thanks for info. The unit is 7 months old. The igniter/sensor has been replaced. It's not a problem proving flame. If it lights, it stays. It just doesn't light every time. I've even played with gas...
  15. Replies
    16
    Views
    3,963

    I agree, they are simple. There are no...

    I agree, they are simple. There are no adjustments. MUA= make up air. Sorry for poor acronym. If it lights, it stays. Not a problem with sensor. It just doesn't always light. Any fixes for...
  16. Replies
    16
    Views
    3,963

    Middleby-Marshall PS536 GS

    Anyone had any trouble with ignition on these ovens? I got one that really gives me fits. It will light 3 out of 4 times usually. Good gas pressure, good spark. I'm beginning to suspect building air...
  17. Replies
    1
    Views
    498

    Kolpak walk-in

    I'm having trouble with a walk-in with 6 display doors. The problem is with one of the lights for the display. It has 6 lights, 3 ballasts. The display doors are made by Commercial refrigerator door...
  18. Replies
    8
    Views
    1,523

    FYI.... Changed gaskets. Found hole in weld on...

    FYI.... Changed gaskets. Found hole in weld on heat exchanger.
  19. Replies
    8
    Views
    1,523

    They use a hand pump and hook it to the delime...

    They use a hand pump and hook it to the delime port on the left side. Actually, according to Blodgett there is no way to force the unit into delime unless the board is calling for it. I heard you...
  20. Replies
    8
    Views
    1,523

    I understand the steam on demand button, but if...

    I understand the steam on demand button, but if the delime lamp isn't on, it won't go into delime. It's got a water filter and a scale stick on it. I ordered the gaskets, but I agree, when I tear it...
  21. Replies
    10
    Views
    2,512

    Clean face of burners. Also clean pilot. These...

    Clean face of burners. Also clean pilot. These are notorious for "booming". Mesh screen on burner face gets greasy and dirty easily. Pitco actually has a "self cleaning burner kit" for these. Pitco =...
  22. Replies
    8
    Views
    1,523

    You know, I didn't actually see the leaking...

    You know, I didn't actually see the leaking gasket. I spoke to Blodgett about it and they told me what to order. Water is dripping down onto the burners. The drain pump is operational. I had to jump...
  23. Replies
    8
    Views
    1,523

    Blodgett combi

    Anyone ever changed the gaskets on the heat exchanger tubes on a BC14G? I got one thats 4 months old and they're leaking. Just wondering how tough it is.
  24. Replies
    2
    Views
    1,436

    Thank you very much for info!

    Thank you very much for info!
  25. Replies
    2
    Views
    1,436

    Honeywell ign. module

    Anyone seen the honeywell s86 spark ign module with the ECOM plug? The module is black. It's on a new Lincoln X2 oven. Really giving some intermittent ignition problems. Can't get a good microamp...
  26. Thread: Subway NUVU

    by howardgt
    Replies
    2
    Views
    1,417

    Check the heat probe. I've seen them break down...

    Check the heat probe. I've seen them break down when oven heats up. I think it's a thermocouple type. Although, every time I've had a bad probe, it was under heating.
  27. Thread: parts

    by howardgt
    Replies
    6
    Views
    1,506

    Commercial Parts and Service at...

    Commercial Parts and Service at http://www.cpsohio.com
  28. Replies
    6
    Views
    786

    I can't get that rhsc.net site to work? My pan...

    I can't get that rhsc.net site to work? My pan heater is working. It freezes in the 4 inch long outlet tube. The actual pvc outside drain line never freezes.
  29. Replies
    6
    Views
    786

    Does anyone know a part number or manufacturer of...

    Does anyone know a part number or manufacturer of these? I'm having trouble with a Kolpak package W-I freezer. The drain outlet tube keeps freezing. My local supply house doesn't know what I'm...
  30. Replies
    2
    Views
    656

    Went to a Little Ceasers pizza today. Saw a new...

    Went to a Little Ceasers pizza today. Saw a new copeland condensing unit on the roof for a walk in cooler- r-134a. My question is the old unit, that is still on the roof, had a headmaster valve on it...
Results 1 to 30 of 36
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event