Search:

Type: Posts; User: akelesis

Page 1 of 15 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    324

    x2 also agree with t527ed

    x2

    also agree with t527ed
  2. Replies
    28
    Views
    872

    when you do wash the coil make sure the water...

    when you do wash the coil make sure the water goes thru the fins of the condenser(pressure washing might be needed).

    if it does make sure the fans are running the right way. blowing out. and...
  3. Thread: Feeling dumb

    by akelesis
    Replies
    23
    Views
    2,146

    i learned a quick lesson. i was replacing a...

    i learned a quick lesson. i was replacing a blower motor for a rtu and it sits above the kitchen so i wiped down the squirel cage never thought about the dirty falling into ppl food down...
  4. i use evap foam cleaner cans and then go over it...

    i use evap foam cleaner cans and then go over it with water.. works really well. i find the viper stuff doesnt work as well. but thats my opinion.
  5. Replies
    28
    Views
    1,868

    I would phone up the boss and let him decide I...

    I would phone up the boss and let him decide I wouldnt even try to anything re routing the line set would be the only option
  6. Replies
    8
    Views
    1,185

    Ummm interesting shouldnt it be aluminum not...

    Ummm interesting shouldnt it be aluminum not galvanized steel.
  7. Replies
    20
    Views
    649

    sometimes when its hard to pull down. i usually ...

    sometimes when its hard to pull down. i usually do a second round of dry nitrogen and then put it on vacuum. usually you can get it down to 1000 in like 10-15 mins.
    maybe a leak?
  8. Replies
    5
    Views
    1,520

    at least it was safely strapped and tapped. i...

    at least it was safely strapped and tapped. i have seen a lot worse.
  9. Replies
    7
    Views
    453

    i found a good way but its just easier i leave...

    i found a good way but its just easier
    i leave the paper on so i know what belt it is. I hate reading it off the actually belt (print)

    and i usually hang it off the back door. with 2 straps ...
  10. Replies
    22
    Views
    1,720

    thats why organization sucks ha ha ha ha i...

    thats why organization sucks ha ha ha ha i always change or organize my truck one step at a time. and this might sound stupid but my bins are labelled ie. refrigeration heating misc. ...
  11. Replies
    21
    Views
    2,893

    i guess it can be a code, but i was always taught...

    i guess it can be a code, but i was always taught to do it that way. Our governed body TSSA are on more sites, most jobs we do are viewed and signed off by them. We do have a few gas I techs and i...
  12. Thread: Need a meter.

    by akelesis
    Replies
    11
    Views
    744

    i have this kit for a few years now its a...

    i have this kit for a few years now its a 116-322 Hvac/r combo

    https://media.westburne.ca/shopimages/canadamedia/4/7/8/8796541288478.jpg

    I have the Extech meter(hvac/r) version as a back up.
  13. Replies
    13
    Views
    712

    Have you gone thru your first schooling yet? ...

    Have you gone thru your first schooling yet?

    Work will get better trust me, the day you get good at what you do, you will re consider not switching back to residential.
    I was in the same boat....
  14. Replies
    24
    Views
    1,361

    well. i was taught a cracks a crack. doesnt...

    well. i was taught a cracks a crack. doesnt matter how small it is. and my boss brang up a good point. we dont know when we are going to be back so before it gets worse shut it down when you have...
  15. Thread: Manometers

    by akelesis
    Replies
    10
    Views
    742

    Just to repost. i do also have the yellow jacket...

    Just to repost. i do also have the yellow jacket gas manometer. not that one that i showed in the previous post. it works well and i highly recommend it.
  16. Replies
    21
    Views
    2,893

    not to be a rude about it. but i thought that you...

    not to be a rude about it. but i thought that you have to support the gas pipe 3 ways on a tee. other then that it would be great fun working with a cool lead guy throught this project. Looked...
  17. Thread: Manometers

    by akelesis
    Replies
    10
    Views
    742

    http://i.ebayimg.com/00/s/MzI3WDI4MA==/z/X8wAAOxyw...

    http://i.ebayimg.com/00/s/MzI3WDI4MA==/z/X8wAAOxywh1TC1PG/$_12.JPG

    I have this one and the water manometer on my truck. make sure you get one that fits the pressures you want. 0-4"w.c....
  18. Replies
    10
    Views
    600

    it is a true fact that....bringing air from...

    it is a true fact that....bringing air from outside extends the life of your furnace breaking down.
    thats why when i come to a house with a furnace connected to the chimney i always recommend fresh...
  19. Replies
    4
    Views
    443

    sorry for the repost. i should have looked in the...

    sorry for the repost. i should have looked in the archives going to check out the local hardware store for magnets that will do the trick. i really dont think the price is reasonable. great idea....
  20. Replies
    4
    Views
    443

    New Tool feedback

    Hey all.

    Just wondering if anyone here has a few of these its called the hvac strap. thinking of picking some up for this summer.


    http://www.hvacstrap.com/

    i think the price is a little...
  21. Replies
    21
    Views
    1,440

    Its a really good too. Any tech should have one...

    Its a really good too. Any tech should have one on their truck. I have a Rigid camera "the snake" works well.
  22. Replies
    18
    Views
    1,104

    i would check the thermostat check the...

    i would check the thermostat check the programming. i would pay attention to the ***safeties*** its tripping out for some reason or another.
  23. Replies
    29
    Views
    1,597

    when u have a plugged cap, u will have high...

    when u have a plugged cap, u will have high discharge and abnormally low suction. make the call to pressurize the system and find that leak. good luck Galt
  24. Replies
    132
    Views
    8,346

    what ever u do dont get rigid its a piece of...

    what ever u do dont get rigid its a piece of crap. i have had problems with it. i would go with anything else.
    check out this place but its in Ontario

    IHL canada they have deals all the...
  25. Replies
    14
    Views
    1,294

    422861 i would say that this combo will do you...

    422861

    i would say that this combo will do you good. i had mines for a few years now and its been great!
    116/322