Search:

Type: Posts; User: kchest4063

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    20
    Views
    1,845

    The T&P drain pipe is also not up to code. It's...

    The T&P drain pipe is also not up to code. It's supposed to go straight down from the T&P and terminate between 3-6 inches from the floor.
  2. I'm a little surprised the guy didn't have a...

    I'm a little surprised the guy didn't have a Lennox Pulse, a Carier Triple Split or maybe an Amana HTM in there just to make things even more exciting!
  3. Replies
    38
    Views
    3,966

    The number in the ad is still good...I just...

    The number in the ad is still good...I just talked to the guy. He's in South Carolina and was wondering why somebody from Kansas City was calling him. Told him I had a rental property in South...
  4. There are a few guys on YouTube that have some...

    There are a few guys on YouTube that have some good stuff. My favorite by far is grayfurnaceman. He sticks to the subject and dosen't make the videos about himself. Some of the info is pretty...
  5. Replies
    30
    Views
    1,678

    I switched to HVAC after being an IT headhunter...

    I switched to HVAC after being an IT headhunter for 20 years. Like you, I couldn't stand the corporate BS and wanted to be out and about, not stuck behind a desk. I have a Bachelor's degree so I...
  6. Thread: Burnout

    by kchest4063
    Replies
    8
    Views
    480

    Lots of variables here, and lots of information...

    Lots of variables here, and lots of information we don't have. I'd definitely be inclined to replace the evaporator and lineset, though. The customer is already getting a new condensing unit and...
  7. Replies
    2
    Views
    297

    According to searspartsdirect.com, the...

    According to searspartsdirect.com, the crosslighter is No Longer Available. That's kind of strange, because I just changed one of those last year. Maybe Heil or ICP could help you out.
  8. Replies
    16
    Views
    1,401

    Let me know

    I was told by ICP that it couldn't be done...or at least there isn't an ICP approved way to do it without voiding the warranty. I've definitely thought about doing it, though.
  9. Can't seem to find any nits to pick on this one. ...

    Can't seem to find any nits to pick on this one. Really like the metal stands as a way to keep equipment off the basement floor. That must have made it a much easier install. Good job!
  10. Replies
    41
    Views
    2,762

    From what I've seen , diesels tend to have higher...

    From what I've seen , diesels tend to have higher maintenance costs, and fuel is obviously more expensive. At the same time, they will usually last longer and may be a little more reliable.
  11. Replies
    37
    Views
    1,844

    Same here. We have a bunch of old Heil Quaker...

    Same here. We have a bunch of old Heil Quaker condensing units from the 1980's that we service under a maintenance agreement. They have the really large oval run caps and they never seem to go bad....
  12. Replies
    14
    Views
    2,547

    Very nice work, it does my heart good to see some...

    Very nice work, it does my heart good to see some nice sheet metal work after dealing with crapola installs all day! Looks like both units should have plenty of airflow.

    And yes, Infinity is...
  13. Thread: Wages

    by kchest4063
    Replies
    138
    Views
    15,372

    I'm in Kansas City, and the pay isn't too bad. I...

    I'm in Kansas City, and the pay isn't too bad. I get $22/hour + all the overtime I can handle, residential only. Also get commission on maintenance agreements and 5% of the gross sales on any sales...
  14. Think this might be why you have airflow problems?

    Got stuck with this today when I was working in the Hood. Customer says "the air comes out cold, but it don't come out very fast."

    http://i142.photobucket.com/albums/r119/kchest4063/Airflow1.jpg...
  15. Replies
    32
    Views
    1,821

    Kroil is the absolute best penetrating oil ever. ...

    Kroil is the absolute best penetrating oil ever. It's kind of expensive, but one can will last you a couple of years. I use the Ultimate Puller on the really stubborn ones, but those are few and...
  16. Looks like Nick's Handyman found work as an HVAC...

    Looks like Nick's Handyman found work as an HVAC tech!
  17. Replies
    61
    Views
    6,953

    I love it when he thinks the pressures are low...

    I love it when he thinks the pressures are low and he says "I'm gonna get my leak detector and find the leak then braze the lines...actually I'm not gonna let the Freon out when I braze the lines cuz...
  18. Replies
    9
    Views
    622

    I wind them up and loop through the holes just...

    I wind them up and loop through the holes just like you're saying. Maybe I need to slow down and be a little more gentle with them or something.
  19. Replies
    9
    Views
    622

    There are 3 little screws on one side and 3...

    There are 3 little screws on one side and 3 little nuts on the opposite side. I've seen some that don't have the screws, but I have some that do.
  20. Replies
    26
    Views
    1,233

    As other have said, a CO detector is a very...

    As other have said, a CO detector is a very helpful tool when it comes to checking for cracked heat exchangers. Sometimes, it's the ONLY way you can tell, short of pulling the heat exchanger. I'd...
  21. Replies
    32
    Views
    1,889

    The simplest thing is to get a psychrometric app...

    The simplest thing is to get a psychrometric app for your phone or tablet, plug in WB and DB and be done with it. I use Air Lite Psychrometric from the Google Play store for my Samsung phone. Works...
  22. Replies
    9
    Views
    622

    Thanks for the input guys. I have the Fieldpiece...

    Thanks for the input guys. I have the Fieldpiece dual temp thermometer, but the leads Fieldpiece supplied are cheap and not as robust as the Fluke leads. The only redeeming thing about the...
  23. Replies
    9
    Views
    622

    Best K Type Thermocouple

    I'm having a hard time finding a K Type Thermocouple that will last more than a month or so. I try to be gentle with them, am careful about how I wind them up when I'm done with them, but it seems...
  24. Replies
    2
    Views
    1,174

    Sometimes I just don't understand hacks. Seems...

    Sometimes I just don't understand hacks. Seems like it would have been cheaper and easier to do it right the first time!
  25. Replies
    32
    Views
    1,889

    There is some great advice in this thread. About...

    There is some great advice in this thread. About the only thing I have to add is don't be afraid to ask questions in class. I guarantee you that you're not the only student that has the same...