    It will not let me add by left clicking. I am...

    It will not let me add by left clicking. I am waiting for permission to cycle power because this unit is controlling a clean room. I hope it takes the configuration and up-dates the changes after the...
  2. Replies
    7
    Views
    1,154

    Does anyone know if I need to Re-Start the...

    Does anyone know if I need to Re-Start the station after you make the station a BBMD to be able to modify the BDT?
  3. Replies
    7
    Views
    1,154

    Tridium AX BBMD

    How do you add a BBMD to a Niagara panel. Do you add this under the Link tab?
  4. Replies
    0
    Views
    299

    Cypress Envirosystems BBMD

    Does anyone out there know if Cypress Environsystems Green Box has a BBMD? The documentation say's its BBMD enabled but I do not know where to go to get this... Anyone out there deal with this...
  5. Replies
    2
    Views
    811

    ASI Controller.... ASIC/2-8040

    I wanted to know if this was a BaCnet device that I would be able to integrate into a siemens system via BaCnet?
  6. Replies
    5
    Views
    1,112

    Thanks Bill. Is there a default log on that...

    Thanks Bill. Is there a default log on that JCI uses to get into these controllers?
  7. Replies
    5
    Views
    1,112

    What Baud Rate do you use for Hyperterminal.

    What Baud Rate do you use for Hyperterminal.
  8. ÄB.CTWR1.SS#2 Must have the same virtual address...

    ÄB.CTWR1.SS#2 Must have the same virtual address as the DI virtual address within the L2SL.
  9. Replies
    5
    Views
    1,112

    Johnson Controls N31

    I have a site that we have taken over that has a JCI N31. I have Project Builder abd Site Book.... How do I get into the N31 and upload into the project builder? What type of cables do I need?
  10. Replies
    4
    Views
    945

    Trane Voyager Supply Air Reset

    I have a Trane voyger unit, 25-50 ton unit that i'm trying to install a supply air reset from a siemens system. I was told all I need a reset board that has a 0-10 VDC input and a 0-1000 ohm output....
  11. Replies
    4
    Views
    437

    it has an extermal Reset board that connects to...

    it has an extermal Reset board that connects to terminals 12 and 15...
  12. Replies
    4
    Views
    437

    it has an extermal Reset board that connects to...

    it has an extermal Reset board that connects to terminals 12 and 15...
  13. Replies
    4
    Views
    437

    Carrier Model # 48DK044

    I have a Box car Air Handler thats a Carrier Model # 48DK044 that has a Supply Air Reset board in it and im trying to find out if it can take a 0-10 VDC signal to it. Anyone??????
  14. Replies
    29
    Views
    4,111

    you will have to get your hands on wincis. that...

    you will have to get your hands on wincis. that will take care of your problem
  15. Replies
    18
    Views
    46,738

    How to Calculate BTU's on CHW System

    Whats a good way to calculate BTU'S on a chilled water system.
  16. Replies
    19
    Views
    1,476

    I would run any kind of reports you could on your...

    I would run any kind of reports you could on your DDC Panels through your work station to find any failed points and and Programming that could help save energy.
  17. Replies
    13
    Views
    1,596

    Try uploading the panel

    Try uploading the panel
  18. Replies
    9
    Views
    4,881

    what exactly does DMS stand for im pretty new to...

    what exactly does DMS stand for im pretty new to the controls industries and only know siemens software