  1. Replies
    12
    Views
    973

    At least they fused it. Lol

    At least they fused it. Lol
  2. Replies
    16
    Views
    531

    The MCC is 14.2a, so using 1.56 as a divider...

    The MCC is 14.2a, so using 1.56 as a divider rla= 9.1a, good guess snapperhead.
    Using 1.4a (14.2/1.4) = 10.1 rla. So ya your getting close to maxing this guy out on pull downs out of defrost it...
  3. Replies
    26
    Views
    1,990

    If it uses 2 psi gas to a regulator before the...

    If it uses 2 psi gas to a regulator before the unit, pull the vent limiter or vent tubing and clean it out.
    Also gas pressure can be tested and should be -.2" wc
  4. Replies
    16
    Views
    531

    Is the cap tube wrapped around the suction line?...

    Is the cap tube wrapped around the suction line? I agree with 2sac it seems like it pulling down fine...
    Is it possible there may have been no restriction before, just low on gas.
  5. Replies
    12
    Views
    460

    Yup, heat it up. Never had a problem

    Yup, heat it up. Never had a problem
  6. Bad evap motor or motor going the wrong way......

    Bad evap motor or motor going the wrong way... just my wag.
  7. Replies
    16
    Views
    831

    Testo 510, you'll make him very happy. And it is...

    Testo 510, you'll make him very happy. And it is about $160-170 range if u shop around.
  8. Thread: Coil gun.

    by Dchappa21
    Replies
    9
    Views
    414

    I've had mine for 5 years or so and think I've...

    I've had mine for 5 years or so and think I've use my pump sprayer maybe 5 times since I've had it..... And that was because there was no water connections around. Not sure why anyone would use a...
  9. The was the price the sporlan rep told me... I'm...

    The was the price the sporlan rep told me... I'm sure he didn't want to say anything to low because it was in front of a wholesaler. So yes $400 sounds like a decent price.
  10. Android app is still 6 months out. And MSRP is...

    Android app is still 6 months out. And MSRP is $599.
  11. Replies
    34
    Views
    19,560

    I use brazing rod on coils and never had one I...

    I use brazing rod on coils and never had one I couldn't fix.... but if I had to I would use stay Brite #8. I have no problem with it. I've used it on suction driers that were going to be un sweated...
  12. Replies
    69
    Views
    3,025

    Start looking a for a new job.. Your boss sounds...

    Start looking a for a new job.. Your boss sounds like a scumbag.
  13. Replies
    10
    Views
    1,167

    That was close....

    That was close....
  14. Replies
    21
    Views
    985

    I normally move it to the liquid line. Lol

    I normally move it to the liquid line. Lol
  15. Replies
    21
    Views
    985

    Cch doesn't work during power outtages..... but I...

    Cch doesn't work during power outtages..... but I do agree it does seem like a bunch of BS... every one I've installed has scroll and a accumulator as well.
  16. Replies
    21
    Views
    985

    With it shutting off on the lp control it cycles...

    With it shutting off on the lp control it cycles like a normal unit.
  17. Replies
    21
    Views
    985

    Only does it after you cycle power off. Then back...

    Only does it after you cycle power off. Then back on.
  18. Replies
    15
    Views
    670

    I'm paying 2.38 a gallon here.... I'll take it...

    I'm paying 2.38 a gallon here.... I'll take it over oil any day. :gah:
  19. Replies
    18
    Views
    1,253

    Seen them installed next to windows in old mill...

    Seen them installed next to windows in old mill buildings.... but they boxed in the windows with plywood... It worked.
  20. Thanks for the video.. took me right back to my...

    Thanks for the video.. took me right back to my green years. I can remember watching the whole series on vhs when I first started.
  21. Thread: Clogpopper ?

    by Dchappa21
    Replies
    7
    Views
    720

    This thing looks like a home made tool that...

    This thing looks like a home made tool that someone came up with when they couldn't find there shop vac. Right up there with the mighty pump.
  22. Replies
    34
    Views
    3,987

    Had my tech pac since Christmas. No problems...

    Had my tech pac since Christmas. No problems yet... I did have to send my LC in 3 times over 5 years.... which doesn't seem to bad to me... hopefully the tech pac holds up the same...
  23. Replies
    7
    Views
    771

    X 4... except I don't need the little carrying...

    X 4... except I don't need the little carrying chase. I would just through a couple of pressure probes in the veto.
  24. Replies
    65
    Views
    3,109

    Might want to install a high pressure switch on...

    Might want to install a high pressure switch on that biatch.
  25. Replies
    37
    Views
    2,445

    I'll have to remember that one... some york and...

    I'll have to remember that one... some york and carrier units use torx screws. T25? Maybe.
  26. Replies
    37
    Views
    2,445

    Has anyone had to use the damaged core remover...

    Has anyone had to use the damaged core remover side?? Does it actually work?
    I agree I have no use for a square bit on my multi screwdriver...
    Think I might prefer a torque bit for locking...
  27. Replies
    18
    Views
    859

    Use nylog to seal it... your talking about the...

    Use nylog to seal it... your talking about the bottom adjustment cap, right?
  28. Replies
    3
    Views
    390

    Yep, run the pump while un sweating and just...

    Yep, run the pump while un sweating and just barley crack the valve on your pump and gauges.
  29. I think im wrong. I think it needs to have more...

    I think im wrong. I think it needs to have more than 50 pounds in it for them to care.
  30. The epa would disagree

    The epa would disagree
  31. Replies
    4
    Views
    425

    Looks like I can see some of the equipment I...

    Looks like I can see some of the equipment I added first. Maybe it hasn't updated all my info yet?
  32. Replies
    4
    Views
    425

    Been using this and like it but I can't view my...

    Been using this and like it but I can't view my equipment sense you recoded it today... still have the locations but can't see the units...
  33. Replies
    10
    Views
    620

    Time to call for service

    Time to call for service
  34. Seen the label on 134a showing that too. Even...

    Seen the label on 134a showing that too. Even though it's not a blend.
  35. Thread: Forane 22

    by Dchappa21
    Replies
    3
    Views
    266

    My favorite is mexichem.... Have only seen it in...

    My favorite is mexichem.... Have only seen it in r404a though.

    I've seen plenty of forane it's been around along time.
  36. Replies
    10
    Views
    748

    Thanks ice.. That will come in handy. I like the...

    Thanks ice.. That will come in handy. I like the MCC and a couple different btu specs.
  37. Dude install a low pressure control. The valve is...

    Dude install a low pressure control. The valve is fine but you may want to change the oil if you really have moisture in the system. Or just keep changing the drier until your glass stays green........
  38. Replies
    12
    Views
    573

    +2 Sent from my SM-G900V using Tapatalk

    +2

    Sent from my SM-G900V using Tapatalk
  39. Got my today too. Will try them this week. Thanks...

    Got my today too. Will try them this week. Thanks for the info


    Sent from my SM-G900V using Tapatalk
  40. Replies
    66
    Views
    6,791

    I'm happy I got my magnet.! But I got a perfectly...

    I'm happy I got my magnet.! But I got a perfectly working sc56....
    It's pretty nice to have manufactures actually listen to what techs are asking for.

    Sent from my SM-G900V using Tapatalk
  41. Thread: pump down

    by Dchappa21
    Replies
    20
    Views
    1,364

    Most low temp pumps also don't like starting with...

    Most low temp pumps also don't like starting with a high suction pressure.


    Sent from my SM-G900V using Tapatalk
  42. Thread: pump down

    by Dchappa21
    Replies
    20
    Views
    1,364

    Main reasons would be to prevent liquid migration...

    Main reasons would be to prevent liquid migration and prevent flood back on start.

    Sent from my SM-G900V using Tapatalk
  43. Ok, thanks email sent.

    Ok, thanks email sent.
  44. Hey Chris I emailed appion a while ago about my...

    Hey Chris I emailed appion a while ago about my plungers not grabbing the cores on live systems and never got a response.... Should I just keep emailing? Or try calling???

    I bought 2 of these back...
  45. Replies
    18
    Views
    972

    I use the bullseye too if needed... but most of...

    I use the bullseye too if needed... but most of the time I use the nozzle from my coil gun

    Sent from my SM-G900V using Tapatalk
  46. Replies
    15
    Views
    941

    Is the distributor mounted vertical or...

    Is the distributor mounted vertical or horizontal???

    If horizontal is it the top tube not feeding?
  47. Replies
    12
    Views
    2,622

    This was almost 9 years ago... Hope it's fixed or...

    This was almost 9 years ago... Hope it's fixed or replaced by now. :grin2:
  48. Replies
    6
    Views
    716

    Agree, can't go wrong with a Weber. I got a...

    Agree, can't go wrong with a Weber. I got a Genesis 330 about 5 years ago and still looks and works like new... Only thing I've had to do to it was clean some spider webs out of the burner orifices....
  49. Replies
    13
    Views
    1,196

    I also keep a graingers 1/2 and 1/3 hp universal...

    I also keep a graingers 1/2 and 1/3 hp universal motors on the truck. Don't know the part number off the top of my head though.
  50. Replies
    13
    Views
    1,196

    AO Smith 9721 will work on almost any walk in...

    AO Smith 9721 will work on almost any walk in cooler or freezer. Also keep a 16w,9w,6w,5w cw 120v on the truck... 50watt motors come in handy too on some smaller condensing units.