Search:

Type: Posts; User: Juleous

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    102
    Views
    15,041

    Being your a new tech some info would help a lot....

    Being your a new tech some info would help a lot. Any line to another line should give the same readings resistance wise no matter what line to what line. The reading would be somewhere likely around...
  2. Replies
    24
    Views
    5,534

    Started 4 30 Ton units this summer, two had came...

    Started 4 30 Ton units this summer, two had came from the factory with leaks in the coils. Both tube sheet one evaporator and one condenser, real pain in the butt to find very windy which made it...
  3. Thread: My Supper

    by Juleous
    Replies
    9
    Views
    806

    Who cooks steak in a pan, that meat is meant for...

    Who cooks steak in a pan, that meat is meant for a BBQ.
  4. Thread: Newbie here

    by Juleous
    Replies
    41
    Views
    2,466

    Clean the outdoor coil.

    Clean the outdoor coil.
  5. Thread: Newbie here

    by Juleous
    Replies
    41
    Views
    2,466

    Clean the blower.

    Clean the blower.
  6. Thread: Newbie here

    by Juleous
    Replies
    41
    Views
    2,466

    Clean the indoor coil.

    Clean the indoor coil.
  7. Not really asking too much anyone in Canada could...

    Not really asking too much anyone in Canada could do it.
  8. Thread: Newbie here

    by Juleous
    Replies
    41
    Views
    2,466

    Change the filter.

    Change the filter.
  9. Replies
    13
    Views
    2,365

    I have shut down a few, one guy had another...

    I have shut down a few, one guy had another company come out and turn it back on. We had the inspector come out and he freaked out, the guy that turned it back on lost his ticket for a period and the...
  10. #2

    #2
  11. Replies
    10
    Views
    1,085

    I have pulled out the High Temp in a Jam before.

    I have pulled out the High Temp in a Jam before.
  12. Replies
    15
    Views
    3,226

    What is the treatment situation? To much chem? I...

    What is the treatment situation? To much chem? I have not run into this before just a guess.
  13. That would have hurt, did you get burned? I had a...

    That would have hurt, did you get burned? I had a schrader blow out on me one time burned my hand pretty good.
  14. Replies
    27
    Views
    2,590

    Is that a serious suggestion? Inspection with a...

    Is that a serious suggestion? Inspection with a scope or mirror, Smoke test, I have also closed all supply registers and watched the flame change. Lots of ways to check best is to remove the blower...
  15. Replies
    15
    Views
    1,048

    Push the mode button on the thermostat till it...

    Push the mode button on the thermostat till it say Emergency Heat, leave it set for what ever temp and then turn the breaker back on.
  16. One time I was servicing a Magic Pack unit by...

    One time I was servicing a Magic Pack unit by Armstrong, had the burner out and cleaned it put it all back together and forgot to do up the union. Turned on the unit and the gas actually lit off...
  17. You need one with a timed on cycle and temp off...

    You need one with a timed on cycle and temp off cycle. Shouldn't be hard to find cam-stat still makes them.
  18. Replies
    42
    Views
    4,883

    Screws

    Screws
  19. Replies
    4
    Views
    570

    A bad v-belt can cause that bouncing also, I do...

    A bad v-belt can cause that bouncing also, I do remember installing a reinforcing plate once upon a time.
  20. Replies
    69
    Views
    4,172

    Cause Trane started to do it, so now everyone is.

    Cause Trane started to do it, so now everyone is.
  21. Thread: Hot Gas Valve

    by Juleous
    Replies
    16
    Views
    1,094

    That is a bit of a trick question, there are...

    That is a bit of a trick question, there are lot's of reasons why that could be all would be correct but probably not what he is looking for. My best answer would be the type of defrost operation the...
  22. Replies
    40
    Views
    5,930

    Hard to see where all the pipe goes, I notice the...

    Hard to see where all the pipe goes, I notice the flex lines connected on the other end of the galvanized why? Weird for sure, also it looks like the drain is going uphill a bit there. That is one of...
  23. Replies
    12
    Views
    564

    TQ = Trade Qualification I thought you wanted...

    TQ = Trade Qualification

    I thought you wanted to be a refrigeration guy not a plunger guy. If you like to play with nasty toilets and such then be a plumber if you want a real trade then do the...
  24. Replies
    10
    Views
    1,085

    DIY answers not allowed on this forum.

    DIY answers not allowed on this forum.
  25. Replies
    17
    Views
    2,826

    I really like L-Series Tool Less test features,...

    I really like L-Series Tool Less test features, it sure makes them nice to service. In my opinion one of the better quality designs Lennox has done, one problem is the program settings in the boards...
  26. Replies
    12
    Views
    564

    Your best bet is do the pre-apprenticeship so you...

    Your best bet is do the pre-apprenticeship so you can get a job, then get your TQ and gas together. The most important thing is to get a job with a journeymen who will train you and help you get your...
  27. Thread: Which Veto

    by Juleous
    Replies
    6
    Views
    631

    I use an LC had it for 3 months or so I really...

    I use an LC had it for 3 months or so I really love it, I also had a bag like yours at one time it was leather. I can hold twice as much in the LC as I did in that bag, the XL is massive and I think...
  28. Replies
    47
    Views
    3,353

    I am buying a 116/322 combo kit tomorrow, it...

    I am buying a 116/322 combo kit tomorrow, it looks like it will do everything I need. I have been wanting to use the fluke clamp-on temp device but have not had anything to plug it into. I was...
  29. Replies
    17
    Views
    2,826

    Take 4 18x24x2 pleated and 4 16x20x2 pleated...

    Take 4 18x24x2 pleated and 4 16x20x2 pleated should be it, but I might be wrong.
  30. Replies
    11
    Views
    2,471

    Had that happen this summer on a L-Series also,...

    Had that happen this summer on a L-Series also, good times. Looks like it's a more common problem than I thought.
  31. Replies
    23
    Views
    2,546

    You can buy evaps pre-coated or just buy a can of...

    You can buy evaps pre-coated or just buy a can of the blue spray. I have used it with good success, if I replace an evap coil in a kitchen then I always use the spray before I put it in. Just a...
  32. Thought they only used stainless on heat...

    Thought they only used stainless on heat exchangers that's what we use in the north. Not that humid though. And that email will likely fall on deaf ears but who knows, we will see what carriers...
  33. Replies
    11
    Views
    1,456

    I had a Lennox also do that, L-series unit...

    I had a Lennox also do that, L-series unit flattened the discharge to the condensor.
  34. Replies
    182
    Views
    5,958

    Poll: US laws are so harsh if you got caught with even...

    US laws are so harsh if you got caught with even a joint you are toast, in BC a cop would look at the joint put it back and tell you have a nice day. If that was alcohol you would be toast, drinking...
  35. Replies
    3
    Views
    643

    No DIY answers allowed on this site, read the...

    No DIY answers allowed on this site, read the rules. Otherwise just google 5 wire thermostat install.
  36. Replies
    66
    Views
    9,816

    Doug Lockhart I met that guy at RSL one day when...

    Doug Lockhart I met that guy at RSL one day when he was introducing his new homemade digital gauges, I thought at the time he was a little off but I guess he turned that into something pretty big....
  37. Yes

    Yes
  38. Replies
    66
    Views
    9,816

    Not sure what he ended up doing, I think it cost...

    Not sure what he ended up doing, I think it cost more than they are worth to fix so he didn't do anything with them. Who is Doug and how would he get in contact with him? We use RSL up here.
  39. Replies
    104
    Views
    24,671

    Isn't that the way everyone does it? I use all...

    Isn't that the way everyone does it?

    I use all info available to me to properly charge a system, but I always if I can take it out and weigh exactly the correct weight into the system. If I must...
  40. Replies
    30
    Views
    1,912

    Goodman is the cheapest, worst quality and least...

    Goodman is the cheapest, worst quality and least reliable system out there. I personally hate that brand.
  41. Replies
    66
    Views
    9,816

    My co-workers digicool display quit working and...

    My co-workers digicool display quit working and now he hates them, I have always used an imperial 4way manifold set. I have several sets all the same for different oils and such, my favorite tool is...
  42. Thread: R22 vs R-410

    by Juleous
    Replies
    11
    Views
    2,611

    There are lot's of direct drop-ins for R-22 now...

    There are lot's of direct drop-ins for R-22 now so don't worry about it.
  43. Replies
    23
    Views
    1,672

    My head was spinning. Where in the world did you...

    My head was spinning. Where in the world did you get your numbers? 800 cfm per ton holly airflow!
  44. I was in your position a few years ago but I...

    I was in your position a few years ago but I remember making the run into the liquor store for him to get a bottle also, fun times for sure. I was not in the same $ situation you were in he had a...
  45. Replies
    22
    Views
    3,625

    If you were so smart you would have read the...

    If you were so smart you would have read the forum rules and would know that we can not post DIY answers. I knew right away you were not a pro by your first post so that makes it a DIY answer. I am...
  46. Replies
    6
    Views
    757

    Sounds like they are cycling on the High Pressure...

    Sounds like they are cycling on the High Pressure or High Temperature safety which could be due to poor airflow at the indoor coil. Or you could have major charge issues, the only way to know the...
  47. Replies
    22
    Views
    3,625

    Moving the pilot flame will result in BOOM do not...

    Moving the pilot flame will result in BOOM do not try that. Lot's of reasons I can think of that would cause that, DIY answers are not allowed.
  48. Sounds like your going to do it anyway, let's say...

    Sounds like your going to do it anyway, let's say you do repair the hole. How are you going to pull a vacuum on it and charge exactly 7ozs in it?
  49. Most corrosion problems are caused by short...

    Most corrosion problems are caused by short cycling problems with the unit, this is caused by being oversized and the heat-exchanger never gets hot enough to dry out completely before the burner...
  50. Replies
    19
    Views
    1,592

    Sounds like a grounding issue or phasing issue of...

    Sounds like a grounding issue or phasing issue of the transformer.
Results 1 to 50 of 141
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event