Search:

Type: Posts; User: acddc

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    33
    Views
    2,068

    I second that!

    I second that!
  2. Replies
    3
    Views
    322

    Circon VI Package with Network Integrator is a...

    Circon VI Package with Network Integrator is a great LNS Management Tool!
  3. Replies
    7
    Views
    467

    these guys set the standard in smart flow...

    these guys set the standard in smart flow metering!
  4. Replies
    7
    Views
    436

    Security Fence

    Security Fence
  5. Thread: Calculating BTU

    by acddc
    Replies
    6
    Views
    440

    Wanna keep it simple try this product. ...

    Wanna keep it simple try this product.

    http://www.onicon.com/?gclid=CKOg2snRkr4CFdDm7AodmSAAZA

    Rock solid reputation!
  6. Replies
    7
    Views
    436

    LON goes over many medias. I even know of a case...

    LON goes over many medias. I even know of a case where powerline LON ran over a fence (obvious what type of fence).
    A certain manufacturer of VFD's (Maybe Graham??) used RS-485 LON.

    The Loytec...
  7. Replies
    3
    Views
    186

    Yes. Lon option card is available for this...

    Yes. Lon option card is available for this machine.
  8. Thread: Cheap Training?

    by acddc
    Replies
    13
    Views
    986

    James, Please put a way for me to contact...

    James,
    Please put a way for me to contact you in your personal profile here. I would like to put you in contact with someone in your area that looks like a good fit!
  9. Replies
    5
    Views
    526

    Remember how you felt the first time you walked...

    Remember how you felt the first time you walked into a mechanical room that had chilled water, hot water, steam piping, domestic water piping, just pipes that went everywhere? Remember how it was...
  10. Our team is experimenting with REVIT to enhance...

    Our team is experimenting with REVIT to enhance our control drawings. We are adding attributes to the objects that are autonomous. Add an exhaust fan to a drawing and with it comes the detail,...
  11. Thread: Distech ECC-VAVS

    by acddc
    Replies
    3
    Views
    452

    You have mail.

    You have mail.
  12. Thread: Touch panels

    by acddc
    Replies
    20
    Views
    1,457

    Did you ever install one? It's not just for...

    Did you ever install one?
    It's not just for daisy chaining because the idea is you actually make a loop for redundant ethernet communication. In your post in #14 you said there was no difference in...
  13. Thread: Touch panels

    by acddc
    Replies
    20
    Views
    1,457

    Really? Maybe you would like to explain why it...

    Really? Maybe you would like to explain why it has two ports if it is no different than a single port switched device.
    Is it for looks?
  14. Thread: Touch panels

    by acddc
    Replies
    20
    Views
    1,457

    Maybe this will help! ...

    Maybe this will help!

    http://www.loytec.com/en/products/lvis-touch-panel
  15. Thread: Touch panels

    by acddc
    Replies
    20
    Views
    1,457

    I must of gotten a hell of a deal on my...

    I must of gotten a hell of a deal on my touchscreens also. Oh there the same as grgjohno mentioned.
  16. Replies
    29
    Views
    3,651

    not high jacking the thread but could not resist...

    not high jacking the thread but could not resist to offer a bit of valuable information to RD9000!

    RD9000 if you want to talk about this in further detail start a new thread in the appropriate...
  17. Replies
    8
    Views
    1,152

    Thanks for the update!

    Thanks for the update!
  18. When I worked for McQuay back about 20 Years ago...

    When I worked for McQuay back about 20 Years ago we used "Monitor Software" to calibrate the outdoor air damper counts. this was done during the start up phase of EVERY unit. The process needed to...
  19. Replies
    2
    Views
    460

    Water Main Leak Detection

    Does anyone know of a transmitter (Sound, Flow, Vibration, etc. etc.) to detect if a water main has failed? I have used excessive flow meters/detectors/sensors to perform this on natural gas piping...
  20. Replies
    4
    Views
    759

    No

    No
  21. S4 - Rock Solid Product! Co-Existence of Front...

    S4 - Rock Solid Product!

    Co-Existence of Front End "During" legacy migration process opens up some comfort level when you flip the switch off on the front end.

    Testing / Commissioning can be...
  22. Replies
    4
    Views
    759

    In the screen shot you will see the UCPT to...

    In the screen shot you will see the UCPT to modify to "Unknown" and this should clear the monitor plug-in alarm. Most likely it is on WIRED_LCD_SENSOR by default. If you are using a standard...
  23. Replies
    12
    Views
    1,775

    Automation Server is a European term for devices...

    Automation Server is a European term for devices that are IP and multi-function. Something that is similar to this style is Schneider Struxureware.

    IT knowledge is a necessity, but most things...
  24. Replies
    12
    Views
    1,775

    Air1, Loytec is open protocol with no...

    Air1, Loytec is open protocol with no proprietary. You are correct the 101 is an internal protocol gateway, router and has a built in OPC (Ole Process Control ...
  25. Replies
    12
    Views
    1,775

    Very Fast Campus Network Performance!

    We are in the process of commissioning a campus with 7 buildings. We have implemented Loytec Linx101 routing automation servers for the network infrastructure. The Graphical User Interface is...
  26. Replies
    4
    Views
    719

    Yes. We have used on several occasions. One...

    Yes. We have used on several occasions. One example is integrating the Lochinvar Intellifin boilers into an Alerton project...
  27. Replies
    4
    Views
    719

    Take a look at this ...

    Take a look at this

    http://www.loytec.com/en/products/gateway-lon-bacnet-mbus-modbus-knx/51-lgate-900-cea-709bacnet-gateway

    BACnet object configuration via LNS® “1-button configuration” tool or...
  28. Replies
    28
    Views
    3,486

    a nice thing about doing boiler systems that have...

    a nice thing about doing boiler systems that have Modbus with Loytec L-INX products, is that the L-INX has a built in Modbus protocol analyzer and also a Modbus device scanner.
  29. Replies
    6
    Views
    1,477

    381 Engineer has an awesome one he made.

    381 Engineer has an awesome one he made.
  30. Replies
    14
    Views
    2,091

    I took the time to talk to Loytec US support. ...

    I took the time to talk to Loytec US support.

    The response from Loytec tech support: "Loytec supports their products and can instruct a user how to get a JACE assembled in an IP852 channel (or any...
  31. Replies
    14
    Views
    2,091

    Liebert did not invent air conditioning but the...

    Liebert did not invent air conditioning but the set the standard percision cooling.
  32. Replies
    41
    Views
    4,784

    I think your case is also manufacturer specific...

    I think your case is also manufacturer specific on what happens during a failure. For Loytec some options:

    1. Use smart programmable I/O. Each I/O has an individual program put into each specific...
  33. Replies
    14
    Views
    2,091

    Loytec sets the standards in IP852/LON and can...

    Loytec sets the standards in IP852/LON and can even get the Jace to perform in this environment. Call Loytec and answer some config questions and they will provide you with a quick solution. Loytec...
  34. Replies
    17
    Views
    2,073

    If they are running combustion based equipment...

    If they are running combustion based equipment such as propane powered forklifts then yes air quality will go bad real quick depending on the density use. If the forklifts are battery powered the...
  35. Replies
    17
    Views
    2,073

    how old is the facility and has this been a...

    how old is the facility and has this been a problem since day one? I had a project for Hershey Chocolate that was 1.6M sq/ft cold storage and it took 9 months to get the moisture out of the...
  36. 313111 I just made this mapping table as an...

    313111

    I just made this mapping table as an example for you to see what it will look like....
  37. Replies
    41
    Views
    4,784

    Chris, things are so much clearer to me now. I...

    Chris, things are so much clearer to me now. I couldn't figure out why you refuse to moderate here and now I know since you actually posted some content.

    From your post you have no clue about...
  38. Replies
    41
    Views
    4,784

    Maybe you aren't crossing over to more industrial...

    Maybe you aren't crossing over to more industrial applications, but having instant reload on program modifications and not having your device reboot the I/O is a huge advantage when working on...
  39. Replies
    41
    Views
    4,784

    Well here we go off topic and the hornets nest is...

    Well here we go off topic and the hornets nest is buzzing hahaha!!

    We have all flavors of loytec Linx and Jace products in all versions from R2 to AX from Hawaii, east coast to west, Canada to...
  40. Replies
    41
    Views
    4,784

    the last JACE literature I looked at stated...

    the last JACE literature I looked at stated 500ms. It is possible it may not be current.
    Which JACE are you using with better timing and where is this documentation?*
    I'd like to read it.
  41. Replies
    41
    Views
    4,784

    The Jace does not look to appealing for this...

    The Jace does not look to appealing for this application.

    The JACE fastest is 500ms (note they really mean minimum 800ms).

    You may consider this
    Loytec Linx products can be configured to 10ms...
  42. Replies
    41
    Views
    4,784

    Exucution times are more critical in the PLC...

    Exucution times are more critical in the PLC world vs the BAS environment.

    Its important that modified code; implementation/updates are performed "on the fly" without a re boot etc.

    Initial...
  43. Replies
    8
    Views
    1,304

    its presentations such as this one that indicate...

    its presentations such as this one that indicate the decline of the product.
  44. Replies
    31
    Views
    3,676

    The researchers scoffed at Tridium’s view that...

    The researchers scoffed at Tridium’s view that its customers needed to be better informed about security. “The root cause of these issues is poor design and coding practices from Tridium itself....
  45. Replies
    47
    Views
    7,396

    It seems like to me that some certificate...

    It seems like to me that some certificate handling would go a lot further than just password/user management?
  46. Replies
    47
    Views
    7,396

    Back to topic..... This seems like a...

    Back to topic.....

    This seems like a disadvantage to me.
    ...
  47. Replies
    47
    Views
    7,396

    I hope your listening skills are better than your...

    I hope your listening skills are better than your reading skills!



    So what is the deal with Loytec and the committee members of this message board? I find it amazing that when the brand Loytec...
  48. Replies
    47
    Views
    7,396

    Loytec is doing this right now!

    Loytec is doing this right now!
  49. Replies
    10
    Views
    1,120

    :cheers:

    :cheers:
  50. Replies
    47
    Views
    7,396

    Why would you need to use FOX for interdevice...

    Why would you need to use FOX for interdevice communication when other technologies exist like BACnet and OPC?

    Using BACnet or OPC allows you to select products from various vendors. There are...
Results 1 to 50 of 191
Page 1 of 4 1 2 3 4