  1. Replies
    32
    Views
    2,120

    I pulled the seal and this is what I found. ...

    I pulled the seal and this is what I found. There appears to be discolouration of the stationary seal face and some possible debris. Also, the brass bushing on the shaft appears to have a build-up....
  2. Replies
    32
    Views
    2,120

    I did not see any pitting on the impeller during...

    I did not see any pitting on the impeller during previous repairs but I will inspect closer to rule it out next during next repair.
  3. Replies
    32
    Views
    2,120

    Is there a way to test for this?

    Is there a way to test for this?
  4. Replies
    32
    Views
    2,120

    piping is vertical as in second row. Thanks...

    piping is vertical as in second row.

    Thanks for your help but my pump is not in the orientation of the last three images.
  5. Replies
    32
    Views
    2,120

    5thRoot,, you are right, the vertical set-up is...

    5thRoot,, you are right, the vertical set-up is permitted, yet the motor is not supported, except by the bolts mounting to the bearing assembly. I do not see in the literature where it states it must...
  6. Replies
    32
    Views
    2,120

    Qwerty,, no, in this application I have not...

    Qwerty,, no, in this application I have not tried the maintenance free pump set-up and don't see the need to go down that road at this point.
  7. Replies
    32
    Views
    2,120

    Not sure why TDS is at this level but I have seen...

    Not sure why TDS is at this level but I have seen the reports from the past and the numbers average under 1000 typically. My understanding is that under 2000 ppm is the target. No signs of corrosion...
  8. Replies
    32
    Views
    2,120

    it is verticle orientation. We have had...

    it is verticle orientation. We have had sportatic failures but this is the only repeated failure.
  9. Replies
    32
    Views
    2,120

    Correction of the pump: The current pump is a...

    Correction of the pump:

    The current pump is a Bell and Gossett LD3 iron body three piece 1/4 HP pump.
  10. Replies
    32
    Views
    2,120

    I seem to recall 38 psi.

    I seem to recall 38 psi.
  11. Replies
    32
    Views
    2,120

    Circ Pump Seal Failures

    I have a building with a that has given me a lot of grief due to repeated circulation pump seal failures.

    I have tried going with different seal types, changing out the seal bearing assembly, the...
  12. Replies
    5
    Views
    786

    Thanks guys but I figured it out today after...

    Thanks guys but I figured it out today after going back with a meter that measures Hz.
    After pre-purge the combustion motor should ramp down to 19 Hz. Regardless of adjustments made to pot on board...
  13. Replies
    5
    Views
    786

    ENG A Make up air ignition

    I have a Engineered air DJ 100-0 with a DJM 3.4 controller that has been giving me problems.

    The problem I am having is during light off the pilot wont light unless I block the venter damper and...
  14. Replies
    0
    Views
    364

    Lennox wire diag needed

    Does anyone have access to a Lennox wire diagram?
    Model: GCC16 060 120 4J
    S/N 5602 G 08158
  15. Replies
    2
    Views
    1,332

    Sorry,,, I was actually looking for the slimzone...

    Sorry,,, I was actually looking for the slimzone Premier Manual.
  16. Replies
    2
    Views
    1,332

    Robertshaw Slimzone Deluxe

    Does anyone have a link to the manual for this system?
  17. Replies
    0
    Views
    397

    Dehumidifier Help

    Anyone have any info or links for a dehimidifyiing air handler going under the name Chinook.

    Model: Phi Beta DH25


    There are two Actuating valves on seperate condenser water outlets....
  18. Replies
    4
    Views
    517

    Pulled the heads off compressor #2 today. It was...

    Pulled the heads off compressor #2 today. It was nasty nasty. Top of pistons were pitted really bad. Copper plating around discharge valve seat. One head had a missing spring plate behind the discus...
  19. Replies
    4
    Views
    517

    The oil was good - no metal flakes. It was darker...

    The oil was good - no metal flakes. It was darker than the other circuit yet that was what I was trying to clean up. It has a history of dark oil on this circuit which is getting better yet still...
  20. Replies
    4
    Views
    517

    35 tone Copland Discharge Valves

    I was changing out the drier cores in a Mcquay Alp 150 and found chunks of valve plate inside the drier shell.

    There are two circuits 75 tons aside.

    Each circuit has two 35 ton coplemetics (6D...
  21. Replies
    14
    Views
    1,377

    ??? Check my contact info then send me an EMAIL....

    ???
    Check my contact info then send me an EMAIL. Then I will send you the PDF file. Try Again.


    By the way unit is operable now. It was the sensor!!
  22. Replies
    14
    Views
    1,377

    Send me an email and I will forward it to you.

    Send me an email and I will forward it to you.
  23. Replies
    14
    Views
    1,377

    I have an issue with this unit occasionally...

    I have an issue with this unit occasionally tripping on low water temp fault. I now know the leaving water temp sensor is a 10,000 ohm thermister and I can check its resistance at a given temp to...
  24. Replies
    14
    Views
    1,377

    Thank You! This will help a lot and is greatly...

    Thank You!

    This will help a lot and is greatly appreciated. Not even my trane supplier could provide this to me.

    You Da Man!
  25. Replies
    14
    Views
    1,377

    Thanks Willf650 . The model is GEHB03032H0120RLC.

    Thanks Willf650 . The model is GEHB03032H0120RLC.
  26. Replies
    14
    Views
    1,377

    Trane tracer ZN 510

    Can any one give me a link to read up on these controllers. There is a test and service button on the board. I would like to know what the procedure for use is.
  27. Replies
    5
    Views
    919

    I changed the water filter and have the flow to...

    I changed the water filter and have the flow to the top resevoir pretty good. The flow from the distribution tubes to the evaporator cylinder is just right.

    The problem is the lower water recovery...
  28. Replies
    5
    Views
    919

    Its definately not off of the top bowl. This...

    Its definately not off of the top bowl. This might be part of the problem.

    I have adjusted the ball valve wide open and can't keep the bowl more than 1/4 full. Without enough steady water flow to...
  29. Replies
    5
    Views
    919

    Howe Ice Flaker Poor water distribution

    Howe Ice Flaker By Scotsman
    Model: 2000 - Rl
    S/N 13597 (1993)


    I got a call to work on a Ice Flaker that had damaged distribution tubes. It turns out the "unit iced up". The guys on site -...
  30. Replies
    7
    Views
    1,081

    Correct on the GE part - it was in my notes but...

    Correct on the GE part - it was in my notes but miss posted that part.

    Airflow, I agree sounds like an issue. TD is quite high.

    I am certain the water is treated and has qycol. I will find out...
  31. Replies
    7
    Views
    1,081

    Trane WSHP - Low Leaving Water Temp Fault

    Trane, Model: HB03032H0120RLC , Sn: W03c09297
    Board: Tracer : Zn 5.10

    I have a pump that is going off on Low leaving Water Fault. The loop is on a geothermal setup. The building manager tells...
  32. Replies
    9
    Views
    796

    Hammer Drill Recommendations

    I am looking at picking up a used hammer drill. Boss said he won't buy me one. It is mostly for 3/8 concrete anchors. I think a hilti te5 is what I want.

    What do you guys use?
  33. Replies
    7
    Views
    2,262

    The cost of a new one is very reasonable. It...

    The cost of a new one is very reasonable.
    It looks like a good back up for my H 10.
    If its quality and performance is good I may get one.
  34. Replies
    7
    Views
    2,262

    Yokigawa Top Gun H10

    I saw this on ebay.
    http://cgi.ebay.ca/YOKOGAWA-TOP-GUN-H10X-REFRIGERANT-LEAK-DETECTOR_W0QQitemZ260104721376QQcategoryZ53298QQtcZphotoQQrdZ1QQcmdZViewItem

    Anyone have one? Comments?
  35. Replies
    8
    Views
    727

    Thanks Baldloonie. I didn't know that. I gave...

    Thanks Baldloonie. I didn't know that.

    I gave air mechanical an answer off the cuff. I guess I should have done some research for his pop quiz. I am quite sure my supplier would have informed me...
  36. Replies
    8
    Views
    727

    Honeywell Vision Pro 8000 series - my favorite...

    Honeywell Vision Pro 8000 series - my favorite because if its versatility.
  37. Replies
    8
    Views
    727

    No, I have four years experience in the trade....

    No, I have four years experience in the trade. Just wrote my red seal exam and passed with flying colors. I mostly do commercial Hvac and refrigeration and have very limited residential experience...
  38. Replies
    8
    Views
    727

    Weighing options For Duel Fuel

    Friends older house getting renovated with insulation and windows.

    Heat loss/gain calculation : 48,000 BTUH Heat loss, 18,500 BTUH Heat gain

    He wants duel fuel.
    He wants variable speed.
    He...
  39. Replies
    3
    Views
    786

    Thanks again guys, I have what I need.

    Thanks again guys, I have what I need.
  40. Replies
    3
    Views
    786

    American Standard

    Does anyone have an installation manual for the following model:


    American Standard Variable Speed Furnace Two Stage 60,000 btuh
    AUD060R9V3K
  41. Replies
    4
    Views
    453

    Woo HOOO!!! I Passed!!

    I'm sooo FN Happy! I wrote my Exam last week for my I.P. red seal and just found out I passed!! I guess my kids will be eating a little better and life won't be such a struggle on apprentice wages!...
  42. Replies
    2
    Views
    1,821

    Thanks MikeSq! I fired off an email to...

    Thanks MikeSq!

    I fired off an email to Criosbank and will phone the Carrier number tomorrow. I am prepared to use any Italian friends that I know for translation. You just saved me some time...
  43. Replies
    2
    Views
    1,821

    Criosbank link?

    I am working on a display cooler and need to get a link to the manufacturer for parts and wiring diagrams.

    Criosbank model 280 s/n 0585462a-33.

    Anyone ever delt with these?
  44. Replies
    35
    Views
    2,024

    View Post

    <a
    URL=http://www.speedtest.net]http://www.speedtest.net/result/74481232.png[/URL]
    Wha! Why so slow!
  45. Replies
    3
    Views
    4,927

    Thanks for replies. I am still waiting for...

    Thanks for replies.
    I am still waiting for operating manual and sequence of operation from thermolec.

    Their tech support recently told me it should have an outdoor air thermostat. I went back to...
  46. Replies
    3
    Views
    4,927

    Thermolec Electric Duct heater

    Model: SC-CTPB
    S/N: 153400-001
    Application: Hallway pressurization, 100% fresh air.
    If anyone is familiar with the operation of these units I have some questions.

    It has a D35 control module...
  47. Thread: Guitar solo

    by newgage
    Replies
    115
    Views
    7,844

    Jimi Hendrix - "'Red House", will never cease to...

    Jimi Hendrix - "'Red House", will never cease to amaze me.
    Jimi Hendrix - Villanova Junction
    Jimi Hendrix - Machine Gun, Live at Filmore East

    David Dilmore - Comfortably Numb

    Jimi Page - Too...
  48. Thread: test

    by newgage
    Replies
    0
    Views
    278

    test

    zdasd
  49. Replies
    0
    Views
    622

    Help With Fujitsu Defrost

    If you know these units please check the thread below posted in residential.

    Unit is a Fujitsu Ductless Split Heat Pump.



    http://www.hvac-talk.com/vbb/showthread.php?t=124469
  50. Replies
    12
    Views
    2,100

    :p :D :D :D

    :p :D :D :D