    Pull out and physically clean and dry the sensor...

    Pull out and physically clean and dry the sensor head and inside of the well. When you start it back up, use the inlet valve to restrict the inlet flow to roughly half. I have experienced this more...
  2. Replies
    10
    Views
    1,027

    Its been some time. Between Phx and Tcsn, I am up...

    Its been some time. Between Phx and Tcsn, I am up to 5 units with this exact failure. Well, one was broken at the brazed service port, The rest were wires rubbed against the discharge line leading to...
  3. Replies
    22
    Views
    1,498

    Doesnt matter who you are or what you fix,...

    Doesnt matter who you are or what you fix, manufacturer warranty sucks.
    They pay as if you have the part in hand and are standing next to the equipment with it. Replacement parts are getting crappy....
  4. Thread: Walk-ins

    by few2many
    Replies
    13
    Views
    1,074

    When its over a 110, lots of draught beer and ice...

    When its over a 110, lots of draught beer and ice maker calls.
  5. Replies
    17
    Views
    1,673

    Yup, small independant movie theater, fuses kept...

    Yup, small independant movie theater, fuses kept blowing, and the plastic holder melted or blew apart or something. So they removed the fuses and wired it straight, with the plastic cover and pull...
  6. Replies
    14
    Views
    2,669

    Probably didnt mess anything up. Although the...

    Probably didnt mess anything up. Although the hoshi used stainless evas, the water channel behind can corrode away and youll get seperation on the evap from the refrigerant tubes
  7. Replies
    31
    Views
    2,924

    Hmm, the poodle monkey's make a good point! "we...

    Hmm, the poodle monkey's make a good point!
    "we put this crappy commercial together in the time it takes to save 15% or more on car insurance"
  8. Replies
    5
    Views
    1,252

    You can try to clean them. Dont scratch them much...

    You can try to clean them. Dont scratch them much if at all. May not work after a cleaning. Might work fine after cleaning, then not at all when dry.
  9. Replies
    6
    Views
    721

    I often come across this exact situation and go...

    I often come across this exact situation and go with 76olds advice. I offer my opinion, if they insist I service it, well, I do my best.
  10. Replies
    5
    Views
    1,687

    A simple bottle of windex is what I often use,...

    A simple bottle of windex is what I often use, every restaurant has it. My company sub contracts for a major co2 gas provider, they do medical air, rest co2, welding gasses and the like. So I service...
  11. Replies
    12
    Views
    1,249

    dump valve leaking by?

    dump valve leaking by?
  12. Replies
    21
    Views
    2,400

    You really should have 2 seperate glycol power...

    You really should have 2 seperate glycol power packs. Maybe even 3 since you have 2 towers. One glycol unit is for the beer lines from the cooler to the tower/bar, which should run 29-32*. The other...
  13. From a freezer to a cooler shouldnt be a big...

    From a freezer to a cooler shouldnt be a big deal. Maybe adjust or replace the txv for correct superheat back to the compressor?
    Going from a cooler, to a freezer, as mentioned, would require...
  14. Anyone having problems with the Baeburn 3000?

    I have installed 3 in the last couple years in different systems. They have all had a different failure. One kept full time power on the reversing valve, one stopped controlling the air handler on...
  15. Replies
    10
    Views
    689

    So, any remedy yet? I ask because you said ice...

    So, any remedy yet?
    I ask because you said ice is spilling out of the bin door. This will happen if the ice bin is missing the door bafle. The i/m will build up to the top of the bin, even if its...
  16. Replies
    75
    Views
    5,394

    Yeah, high evep temp should cause a 1 beep. Is...

    Yeah, high evep temp should cause a 1 beep. Is the harvest timer too long? Also, if its just shutting down and staying off, is it a false bin full? (not sure why a false bin full would reset with...
  17. Replies
    6
    Views
    1,504

    I have only seen and worked on one unit. Bad...

    I have only seen and worked on one unit. Bad compressor 3 weeks after install. Hope to hell I never work on one again. We also did the warranty repair work on the franklin coolers. pure crap.
  18. Replies
    10
    Views
    1,027

    Ha! Found you out. I've probably already talked...

    Ha! Found you out. I've probably already talked to you a couple times.
  19. Replies
    10
    Views
    1,027

    I'll be sure to let you know of any oddball...

    I'll be sure to let you know of any oddball situations like this in the future!!!
    What equipment do you do tech support for?
    Sometimes you. get the right person, sometimes the wrong one. Sometimes...
  20. Replies
    10
    Views
    1,027

    Yeah, I dont recall off hand what the amp rating...

    Yeah, I dont recall off hand what the amp rating was, but thats 3phase wiring to the compressor, the 3 legs o power coming in were doing the same to the side of the compressor, but it was more of a...
  21. Replies
    10
    Views
    1,027

    Scotsman (lack of) support RANT

    About a month ago, on a tuesday afternoon, got a call for a supermarket, Scotsman unit not making ice. Store and equipment is less than two years old. Found a scotsman FME1204AS-3B with an open low...
  22. Thread: R 507

    by few2many
    Replies
    24
    Views
    2,165

    I thought I read somewhere on this forum that 507...

    I thought I read somewhere on this forum that 507 was closely related in operating pressures to 404a. Doesnt it have a very close boiling point to 404a?
  23. Replies
    62
    Views
    3,502

    I think he said the fan was cycling correctly.

    I think he said the fan was cycling correctly.
  24. Replies
    44
    Views
    2,484

    This cust was so nice when he needed the work...

    This cust was so nice when he needed the work done, Then so rude when the approved bill came. He herassed and berated me in front of his employees and his restaurant cutomers. I would explain every...
  25. Replies
    44
    Views
    2,484

    It was only a half horse compressor, 4hrs labor...

    It was only a half horse compressor, 4hrs labor and yes to the rest.