  1. That is correct, I totally agree on the ECM...

    That is correct, I totally agree on the ECM blower point.
  2. Haven't heard anyone recommend the Coleman mod...

    Haven't heard anyone recommend the Coleman mod furnace with the ECM blower. I just installed a couple of them and really like them.

    http://colemanac.com/dealers/ProductPage.asp?id=2828&t=r

    I...
  3. Replies
    27
    Views
    3,367

    Try this

    I have had this Bosch impact driver for about a year. It is very powerful-enough to make new holes with a 5/16 screw into a RTU access panel no problem. I wouldn't use it for installation every day,...
  4. Replies
    26
    Views
    1,434

    Bad valves in the pumper

    Bad valves in the pumper
  5. Another Goodman bites the dust

    Replaced another Goodman system this week. Only 5 years old. Took it right to the scrap yard. Customer frustrated by repeated repairs, flimsy vibrating cabinets making noises. Demanded it be replaced...
  6. Replies
    9
    Views
    1,392

    Thanks for all the replies. ERV definitely is...

    Thanks for all the replies.
    ERV definitely is the way to go to recover some of the humidity in the winter, and reverse in the summer.
    I like the idea of no defrost cycle on the Renewaire with that...
  7. Replies
    9
    Views
    1,392

    Feedback using Honeywell ERV in NJ?

    I am considering installing the Honeywell ERV with defrost in my home here in NJ. Part #ER150B2006. My question is has anyone used the Honeywell vs. other brands and why. I have not installed either...
  8. Replies
    34
    Views
    5,759

    I installed a Takagi TK2 in my house 2 years ago....

    I installed a Takagi TK2 in my house 2 years ago. My reasoning was because my old heater needed replacement and the wall mount saved a lot of space in my laundry room. Cost was about 3 times as much...
  9. Replies
    2
    Views
    612

    It's called a rivet nut gun.

    It's called a rivet nut gun.
  10. Replies
    19
    Views
    1,617

    I am familiar with your type of house. It may...

    I am familiar with your type of house.
    It may not matter what size you install (as far as cooling upstairs). Upstairs is always a challenge to cool with one system feeding multiple floors. You may...
  11. Replies
    19
    Views
    1,617

    dcmcm5: I'm not trashing the manual j...

    dcmcm5:

    I'm not trashing the manual j procedure at all, there is nothing wrong with it. My point is- I see posts on here that seem to say throw the contractor and their system in the garbage if...
  12. Replies
    34
    Views
    2,512

    Keep in mind the coil must be cleaned with a...

    Keep in mind the coil must be cleaned with a disinfectant to kill the bacteria not just a coil cleaner. I would also try running the unit a little colder than 78 and making sure everything else in...
  13. "what this means is 2 things: 1) when R-22...

    "what this means is 2 things:
    1) when R-22 becomes obsolete, the cost WILL SKYROCKET in purchasing it. as of right now you can get R-22 for approx $x/pound
    expect to see it go up to $x/pound in...
  14. Replies
    13
    Views
    1,993

    If there is no time difference then how will a...

    If there is no time difference then how will a bigger pump freeze that moisture? That doesn't make sense. You are saying they pull at the same rate.
    I have never heard of or seen moisture freezing...
  15. Replies
    16
    Views
    1,791

    Time is money. Don't waste it on such a small...

    Time is money.
    Don't waste it on such a small pump. I would say a 5 is minimum. The Inficon shark is the best cfm/weight ratio I have found. At 24 pounds and 6 cfm it is the best value in my...
  16. Replies
    19
    Views
    1,617

    If you choose 75 indoor temp remember that's all...

    If you choose 75 indoor temp remember that's all you will get if it is 95 outside, and it will run all day long. What happens when it's over 95? You may not get that 75 inside and it sure will run...
  17. Replies
    41
    Views
    2,767

    When you say the resistance is OK on the...

    When you say the resistance is OK on the compressor - does that mean the values are correct or just not shorted or open. Check the cap with a meter that shows you the uf rating. I would double check...
  18. Your line sizes are perfect for an average 50' or...

    Your line sizes are perfect for an average 50' or so line length.
    Any traces of R-22 will be pulled out with a vacuum pump. The oil will not. If it's difficult to replace it, a proper flush is not...
  19. "Lowest RH was 50% last he checked. He said all...

    "Lowest RH was 50% last he checked. He said all is well with the system. I'm sure it is (pressure wise), it's just not pushing cold enough air. 60 at the closest vent, 70 plus at the furthest. 75...
  20. Those balancing plates get installed right at the...

    Those balancing plates get installed right at the main trunk connection to each outlet run. The small runs of duct are attached by plastic connectors. You simply twist about a quarter turn ccw and...
  21. Thread: info needed

    by shoretrade
    Replies
    13
    Views
    858

    Your best bet is to go to some classes. Get a...

    Your best bet is to go to some classes. Get a class schedule from your local distributor or supply house. They are always running classes and are generally low cost or even free to attend. Studying...
  22. To balance that system you need the balancing...

    To balance that system you need the balancing plates that should have been installed right off the main trunk on each run.
    Your jet engine noise is caused by: not enough air moving through the unit,...
  23. Thread: A/C add on

    by shoretrade
    Replies
    32
    Views
    8,498

    Mook, have you had any problems with the bldg....

    Mook, have you had any problems with the bldg. inspectors approving that bubble wrap for R6 in the attics?
  24. Replies
    30
    Views
    1,832

    You are way oversized. 2.5 tons for 650 ft. at...

    You are way oversized. 2.5 tons for 650 ft. at night with no sun? I'm sure you told him you don't need it down to 65 during the day under peak load. That 3 ton must barely run before it's satisfied....
  25. Replies
    22
    Views
    2,752

    So we are assuming you do a subcooling or...

    So we are assuming you do a subcooling or superheat to check the charge on every unit, on every PM you do?
    Not realistic around here.