  1. Replies
    20
    Views
    706

    Should the liquid line be insulated? I remember...

    Should the liquid line be insulated? I remember being told at a Goodman class that in an attic above 120*F' the liquid line should be insulated. They didn't state why though, but could the attic...
  2. Replies
    16
    Views
    844

    Now guys I'm not at this job because of any...

    Now guys I'm not at this job because of any problems with the cooling haha. The system cools just fine to me. I just had some down time and was scoping out the heating/cooling equipment.
  3. Replies
    16
    Views
    844

    It is 3/8ths out of the condensing unit and...

    It is 3/8ths out of the condensing unit and reduces a few inches downstream of the service valve
  4. Replies
    16
    Views
    844

    Now I thought I learned that a cap tube was a...

    Now I thought I learned that a cap tube was a means of flashing refrigerant into a low pressure low temp liquid. Its a fixed orifice like a piston would be considered. So shouldn't the line be...
  5. Replies
    16
    Views
    844

    Would it be referred to as a cap tube? Its just...

    Would it be referred to as a cap tube? Its just strange how the line isn't even cold at the point the insulation is on it.
  6. Replies
    16
    Views
    844

    Liquid line coiled

    Hey guys, I came upon a strange setup on a non hvac related side job. System cools well, ( says the back of my hand thermometer feeling supply air from a register ), its a newer Lennox furnace with...
  7. Replies
    15
    Views
    1,013

    The 2 valve zeppelin is a nice manifold, and...

    The 2 valve zeppelin is a nice manifold, and relatively cheap too. I'm only working with my JB M2 right now. The main idea of a 4 valve I like most is that you can keep the entire manifold in a...
  8. Replies
    15
    Views
    1,013

    Yep, we have the core removal tools but only one...

    Yep, we have the core removal tools but only one of them, it only was ever used to change schrader cores. The company I'm at is a little behind the times but I"m working on getting them up to speed...
  9. Replies
    15
    Views
    1,013

    4 valve manifold worth it?

    Lately I've been considering looking for a 4 valve manifold. The J/B zeppelin all black ( competitor to the cps black max I suppose ) has caught my eye. For $190 with hoses, almost can't go wrong. ...
  10. Replies
    11
    Views
    548

    Universal multi-hp motors

    Hey guys, just wanted to know some opinions on multi-hp replacement motors. We carry the diversitech blower motors and condenser fan motors. I'm not really impressed with them, my first...
  11. Replies
    14
    Views
    967

    When you let the charge go, which service valve...

    When you let the charge go, which service valve did you open first? I was told at a Goodman class, the suction service valve should be opened first. If you do liquid first you could void the oil...
  12. Thread: Lineset kinks

    by Jack93
    Replies
    8
    Views
    416

    It was just an ac checkup call, i did say service...

    It was just an ac checkup call, i did say service in my original post. But yeah, the fact that it was the suction line with just vapor, I didnt think too heavily on it. Especially since I couldnt...
  13. Thread: Lineset kinks

    by Jack93
    Replies
    8
    Views
    416

    Lineset kinks

    Last week I went on a job, cooling service, 8 year old Goodman 2.5 ton straight cool. I noticed several signs of a hack job, one being the suction line being kinked where they tried making a...
  14. Replies
    35
    Views
    1,610

    If you have a DMM with the ability to read...

    If you have a DMM with the ability to read capacitance, I'd also check the indoor blower run capacitor. Could be weak, causing the blower to run slower than it should. Are you familiar with how to...
  15. Thread: CPS Vacrometer

    by Jack93
    Replies
    1
    Views
    280

    CPS Vacrometer

    I'm having some issues with my CPS micron gauge that's only been used..3 times since I bought it. Had a funky issue the second time. I have it set up at the pump with a tee, ball valve directly on...
  16. Replies
    16
    Views
    910

    Ok, maybe you guys are seeing the name "supco"...

    Ok, maybe you guys are seeing the name "supco" and are thinking of the super boost type kit. The 3w1 kit is a seperate potential relay and start cap. Just like a factory start kit. Black from 5 to...
  17. Replies
    16
    Views
    910

    LOL, how about that. Nice catch!

    LOL, how about that. Nice catch!
  18. Replies
    16
    Views
    910

    Isn't the supco 3w1 kit the same as a 5-2-1...

    Isn't the supco 3w1 kit the same as a 5-2-1 basicly? Actually says it replaces that kit. Both are for 1-3 ton applications
  19. Replies
    16
    Views
    910

    Thing about the noise it makes is, it doesn't do...

    Thing about the noise it makes is, it doesn't do it every time, it's kinda rare to be honest. It's made that noise before. I'm probably being paranoid about it lol, but it's my parents unit so I...
  20. Replies
    16
    Views
    910

    Update on the thread.. Well, the start kit I...

    Update on the thread.. Well, the start kit I ended up getting for it is the Supco 3w1. Seems like a nice little kit, it's the 3 wire version with the potential relay, and bracket that the cap snaps...
  21. Replies
    16
    Views
    910

    Them greedy mofo's

    Them greedy mofo's
  22. Replies
    16
    Views
    910

    Ok, I'll pick one up at the supply house and pop...

    Ok, I'll pick one up at the supply house and pop it in this weekend. I gotta wonder why Bryant wouldn't equip them from the factory with the kit originally. Maybe not all systems were equipped with...
  23. Replies
    16
    Views
    910

    Start assist kit necessary?

    Hey guys, I have a question on the A/C in my parents house. It's a 2 1/2 ton Bryant Evolution 14 seer with a scroll compressor. System has a TXV. The wiring diagram has a spot for an optional...
  24. Replies
    19
    Views
    936

    Explain your last statement there. Condenser TD...

    Explain your last statement there. Condenser TD 0*F? You don't mean my low and high side gauges reading the same do you? Or do u mean temp on the gauge compared with LL temp?

    Is there a way to...
  25. Replies
    19
    Views
    936

    Ditto on that one. I'm going to try the Ice...

    Ditto on that one. I'm going to try the Ice water test.