  1. Replies
    26
    Views
    2,987

    Okay.. For arguments sake and to avoid further...

    Okay.. For arguments sake and to avoid further replies.
    Let's say you went to Joes ford dealership.
    Bought a new ford f150 pickup truck. That came standard with a 5 yr warranty.
    If your dealer...
  2. Replies
    22
    Views
    2,019

    Pump and dump has excellent ewt , but comes with...

    Pump and dump has excellent ewt , but comes with own disadvantages too ( water quality, pumping equipment, more maintanence on waterside).
  3. Replies
    22
    Views
    2,019

    Has anybody flushed or purged the system again.

    Has anybody flushed or purged the system again.
  4. The cycle stop valve is a cheap way to stop the...

    The cycle stop valve is a cheap way to stop the pump from short cycling while using water.
    The best solution we have done is installing a Grundfos constant pressure system to all our open loop...
  5. Replies
    11
    Views
    866

    You already have the loop installed. How much...

    You already have the loop installed. How much could a replacement geothermal costed overhead installing a gas furnace, and A/c unit????
  6. Replies
    2
    Views
    658

    3 GPM is recommended. I've seen open loops run...

    3 GPM is recommended.
    I've seen open loops run as low as 1.5 GPM and be effective since the constant temperature year round doesn't fluctuate in open loops.
    Be aware of the open loop issues with...
  7. Replies
    14
    Views
    2,910

    EPA did not approve the bay loopfield because it...

    EPA did not approve the bay loopfield because it is just that....A bay.
    You must own the waterway your going to use for the loops. In NJ we are not allowed to have closed loops in the bay either,...
  8. Replies
    4
    Views
    883

    Buffer tank water heater set up is more the...

    Buffer tank water heater set up is more the normal practice than good practice.
    Pump and dump can run on a 3/4 pex line if it is a smaller system. It all depends on the flow the system needs.
  9. The downside is also the size restrictions. We...

    The downside is also the size restrictions.
    We typically install 1" loops for our residential homes. The header system only comes in 3/4" inlets with 1 1/4" outlets.
    I was in talks with GeoSolar...
  10. I have never used it, but have seen one. It...

    I have never used it, but have seen one.
    It requires a heating iron with a smaller tip or side mount elements.
    Look at the irons on pipefuser.com .. It's the kits I've bought and use still. The...
  11. Replies
    10
    Views
    3,946

    We bought a b&d manufacturing as a last minute...

    We bought a b&d manufacturing as a last minute resort with a 2hp pump.. We ran out of time to build one so had to purchase it ASAP.
    Building one is quite easy, or you could rig some PVC together...
  12. If 5x150'/ton was sized correctly and transfer...

    If 5x150'/ton was sized correctly and transfer heat efficiently, then 3x250' will not change the outcome at all!
    I usually cut our bore hole count down to save time of rig setup/break down on a...
  13. Replies
    17
    Views
    3,025

    Sorry, don't take it as offensive. LOL I just...

    Sorry, don't take it as offensive. LOL
    I just never seen one before, and frankly don't know why anybody would want a snow scoop?
    I am from NJ where we get a fair bit of snow too, and have never...
  14. Replies
    17
    Views
    3,025

    What is it? A sled or a shovel?

    What is it?
    A sled or a shovel?
  15. Replies
    7
    Views
    1,477

    That's one of my concerns too. Seems like a great...

    That's one of my concerns too. Seems like a great idea until real world scenarios get in the way (swelling clay and running sands in particular).
  16. Replies
    7
    Views
    1,477

    If you want to send me your thought in a PM, that...

    If you want to send me your thought in a PM, that would be great. Im always curious as to others thoughts on different materials. It just seems ike a nightmare to uncoil 2 loops, clipped togethter...
  17. Replies
    7
    Views
    1,477

    Did you get this job? What was your personal...

    Did you get this job?
    What was your personal opinion after further research?
  18. Good decision. Most of the negative opinions are...

    Good decision.
    Most of the negative opinions are from Standard HVAC installers who have never installed or educated on geothermal!
    I am a fan of geothermal, and would always go geo over gas unless...
  19. Replies
    13
    Views
    3,681

    I am hoping your referring to a poor attempt at...

    I am hoping your referring to a poor attempt at "humor" and not a poor attempt at a "hummer" , cause that would just be weird. By the way, I'm not that kind of guy!
  20. Replies
    10
    Views
    2,346

    I glad you got fixed it. If it was a well...

    I glad you got fixed it.
    If it was a well issue it would have Cost more than $600 probably.
  21. Replies
    10
    Views
    2,346

    That's good news (i guess). But you still haven't...

    That's good news (i guess). But you still haven't found the problem ( the bad news).
    Hopefully it's a simple fix. Possibly the Taco ( or other brand) valve on the outlet side of the geo is a good...
  22. Replies
    13
    Views
    3,681

    Congrats on the self install! Although specialty...

    Congrats on the self install!
    Although specialty tools are not required, they sure do aid in the process of simplifying the install. Fusion joints require a certification process, but are less...
  23. Replies
    10
    Views
    2,346

    They seem correct to me for a wx-302. Put even...

    They seem correct to me for a wx-302.
    Put even so, It still seems to sound like a well that is not producing like it may have in the past.
    Your tank is not always FILLED. Some the pump will kick on...
  24. Replies
    22
    Views
    3,895

    judging from the old school water softner in the...

    judging from the old school water softner in the back ground and the second line capped off right next to it. it was either relocated, or that was the old location for the water heater.
  25. www.climatemaster.com www.waterfurnace.com...

    www.climatemaster.com
    www.waterfurnace.com
    they both have caluclators on there sites.
Results 1 to 25 of 59