    just bypass in see wheb unit turned on while...

    just bypass in see wheb unit turned on while checking temp.
  2. Thread: oven flame

    by newbeetech
    Replies
    3
    Views
    659

    good point , but thier low even when im calling...

    good point , but thier low even when im calling for heat and off when not on call,
  3. Replies
    41
    Views
    12,262

    i was thrown into it i needed a job , i said i...

    i was thrown into it i needed a job , i said i could do it and he bilieved me. i become good at it , learn by experiance
  4. Thread: oven flame

    by newbeetech
    Replies
    3
    Views
    659

    oven flame

    im working on an imperial commercial oven, notice the flame on the bottom ,for the oven, was low and not as high as the cooking flames..are they soppost to be that low . im going back after this...
  5. Thread: t-stat

    by newbeetech
    Replies
    2
    Views
    1,074

    t-stat

    hello all , can anyone help me with temp ctrl ( renco etc ) on how to set the temp .
  6. Replies
    1
    Views
    399

    to amp or not to amp

    on heating elements or just loads in general,,, whats the theory is it more resistance more amp draw or the other way around ? im thinking the more current /electrons traveling through the...
  7. Replies
    7
    Views
    953

    contractores licence

    Hello everyone, i was wondering if , by the way I'm in Houston TX, someone can set me in the right direction on getting my contractors license , I'm getting very confusion info from a lot of...
  8. Replies
    1
    Views
    571

    charging reach in coolers or freezer

    wondering when charging crtical charge units, what am i looking for as far as superheat or sucooling and if im an oz short or over what will be the consaquences. the units are cap tube metering...
  9. Replies
    2
    Views
    453

    low or higher then normal

    let's imagine we have a ristriction and the low side goes to a lower then normal psi 0 to a vacuum. what will the hi side psi read and why!!! and the superheat will be ? and the subcool will be at...
  10. Replies
    13
    Views
    1,353

    i blew back into the cap tube in a counter flow...

    i blew back into the cap tube in a counter flow and looks like i had good nitro flow, it will be a blank if i had to replace the cap tube, is there something outthere to claen the cap tube.
  11. Replies
    13
    Views
    1,353

    reach in cooler

    hello all, i replaced the filter drier on a true reah in cooler due to a ristriction. the low side was at 5 psi should have been around 15 psi , and the hi side was at about 300 psi ambient temp at...
  12. Replies
    7
    Views
    1,218

    residential refrigerator

    hello all . i do commercial refrigeration for a living, however my boss ask me to look at hi fridge at home, and like a dumb ass i said i would , however, i never worked on them , is there 2 t-stat ?...
  13. Replies
    3
    Views
    912

    3wire termanator

    im sorry , i guess i was really tire to put down in words what i was thinking, what i meant to ask ,you knoledgeable people was , does anyone have a diagrahm on how the 3 wire termanator is wire on a...
  14. Replies
    3
    Views
    590

    defrost timmer wiring

    can anyone guide me to a site wher i could get more info on defrost timer and the 3 wire terminator wiring diagriam. 1-2-3-4-n-3 terminals. thank you. also on charging, what refregerants is charge in...
  15. Replies
    3
    Views
    623

    reach-in upright cooler

    hello gents, i worked on a under the counter reach in cooler the other day i replaced the comp waight in the charged 11 oz low psi at about 17 unit is up to par . now i have upright cooler with...
  16. Replies
    5
    Views
    863

    never to late to help someone,

    never to late to help someone,
  17. Replies
    5
    Views
    863

    the unit does not have a service valve , make...

    the unit does not have a service valve , make sure when charging the unit that u charge it with liquid , and make sure the bottom plate also frosted, its about 10.5 oz good lick
  18. Replies
    27
    Views
    2,193

    thank you martin&sonsa/c that is what my friend...

    thank you martin&sonsa/c that is what my friend said and guess what the unit is working fine since i charged it in a liquid state, but i wanted to hear some feedback from this site i have been a...
  19. Replies
    27
    Views
    2,193

    my o my ,reeferman why so hursh on me

    my o my ,reeferman why so hursh on me
  20. Replies
    27
    Views
    2,193

    charge gas or liquid

    qoustion , what refrigerats is charge is a liquid or a gas, im having problems with a sushi cooler not reaching temp but everting is running to par. i asked a another tech and he said to charge the...
  21. Replies
    13
    Views
    977

    well thank you itsiceman, i was able to finf the...

    well thank you itsiceman, i was able to finf the problem . after doing all the advise i found the tray had moved out of its area spilling the resoiver water into the bin , thus think that the water...
  22. Replies
    13
    Views
    977

    lol that was great .perfact timimg. now i must...

    lol that was great .perfact timimg. now i must wait till restourant opens by the is there a spell check here in this site
  23. Replies
    13
    Views
    977

    thank u iceman that was a lot of help, i will...

    thank u iceman that was a lot of help, i will check all of the above
  24. Replies
    13
    Views
    977

    thank u so much, the hoshizaki web site said for...

    thank u so much, the hoshizaki web site said for the unit m# km-900maf it does not provide the manuel for it, but still i have read the other web site and your are rite along on what the problem...
  25. Replies
    13
    Views
    977

    that make sense, so what would be a good way to...

    that make sense, so what would be a good way to check the float switch to see that is the problem ? and where is the check valve , bytheway, the pump was stuck i hade to remove the screws and wiggle...
Results 1 to 25 of 309
Page 1 of 13 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event