Search:

Type: Posts; User: cboe

Page 1 of 4 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    5
    Views
    1,375

    I hope you sell the costumer a new furnace....

    I hope you sell the costumer a new furnace. insted of changing out the heat exchanger.
  2. Thread: Water heaters

    by cboe
    Replies
    33
    Views
    3,417

    I learned something about water heaters. If you...

    I learned something about water heaters. If you change out the ANOD rod once in a while you can get a lot of years out of your water heater.
  3. Thread: union math test

    by cboe
    Replies
    29
    Views
    3,628

    when I started in the trade the union had no math...

    when I started in the trade the union had no math test. if they would have had I don't think I could have passed it.
  4. Replies
    6
    Views
    1,022

    got to have subcooling!

    got to have subcooling!
  5. Replies
    615
    Views
    111,135

    I us to work for Lennox and had to drive about...

    I us to work for Lennox and had to drive about 250 miles to adjust the heat intesipator for one of oue so called dealer.
  6. Thread: time clocks

    by cboe
    Replies
    3
    Views
    1,025

    time clocks

    for a walkin freezer to get a clean coil how many defrost and time in 12 hours would be a proper setting?
  7. I am in agreement others that said its the...

    I am in agreement others that said its the indoor motor. could a bad indoor motor capacitor, or bad bearings
  8. Replies
    5
    Views
    1,426

    I carry 2 or 3 extra valve plates in my van...

    I carry 2 or 3 extra valve plates in my van always. it seems like its the calls that takes 2 or 3 hours travel that give you fits. it makes for a good day when you solve a problem like that. I am...
  9. Replies
    21
    Views
    2,626

    Put a defrost clock on it!

    Put a defrost clock on it!
  10. :gah:years ago Lennox made unites that the length...

    :gah:years ago Lennox made unites that the length and dia. of the liquid was the metering device. you void the warranty if you shortened or added to them. needless to say they didn't last long.
  11. Replies
    27
    Views
    3,050

    I am from old school! any where except top or...

    I am from old school! any where except top or bottom.
  12. Thread: Workers unions

    by cboe
    Replies
    71
    Views
    6,002

    I retired from the northern Calif. Sheet metal...

    I retired from the northern Calif. Sheet metal workers Union, after being a member for years than I wont to count, and if it wasn't for the union I would not have what I have today. very good health...
  13. Replies
    26
    Views
    3,505

    or even smaller than a 35+5!!

    or even smaller than a 35+5!!
  14. Replies
    7
    Views
    1,407

    my thoughts too. sol. valve is restricted

    my thoughts too. sol. valve is restricted
  15. Thread: how old are you?

    by cboe
    Replies
    28
    Views
    2,911

    how old are you?

    I was just wondering!
    are any of you older enough to remember GACs? Gas Air Conditioners.
    Arklar Seville, Day and Nite, and Whirlpool just to menton a few.
    The gas companys wonted to keep there...
  16. Replies
    66
    Views
    12,418

    makes you wonder if they got the supply and...

    makes you wonder if they got the supply and returns right? I guess it don't make any diff. they wouldn't know the diff. anyway.:.02:
  17. Replies
    11
    Views
    1,225

    it is possible the unit could be over charged...

    it is possible the unit could be over charged just a tad. that and hi ambiant temp. plus a dirty cond. all this could cause hi cond. pressure. somthing to look for.
  18. Thread: Refigerant leak

    by cboe
    Replies
    8
    Views
    768

    beside a bad brazing job I would look for a...

    beside a bad brazing job I would look for a sheetrock nail or screw. thats very cmmon. good luck on your find.
  19. Replies
    39
    Views
    6,106

    bad valves or internal releaf open

    bad valves or internal releaf open
  20. Replies
    24
    Views
    1,935

    When I use to do service work years ago, when I...

    When I use to do service work years ago, when I changed out a compressor I all ways installed a liquid line drier and a suction filter. regardless if it was a burn out a brown out or bad valves. even...
  21. Replies
    18
    Views
    1,911

    I have had sitiuations like this. after 3 caps I...

    I have had sitiuations like this. after 3 caps I found that the compressor terminals were dirty. cleaned terminals crimped on new stakons, after that no more problems. ckeck for tight connections at...
  22. Replies
    102
    Views
    15,810

    could be quality controle too.chines, mexico, and...

    could be quality controle too.chines, mexico, and USA
  23. Replies
    7
    Views
    5,329

    How about having one here in the Pacific North...

    How about having one here in the Pacific North West.
    years ago we used to get togather at RSES meeting, do folks still have active RSES meetings?
  24. Replies
    15
    Views
    3,244

    I went to do a heatpump add on once on a MH. when...

    I went to do a heatpump add on once on a MH. when we went under the MH to run the reff. lines we found that when the MH was placed they forgot to install the cross over duct to the oher side. all the...
  25. Thread: BIG STUFF!

    by cboe
    Replies
    27
    Views
    6,164

    Now thats Professional. My kind of work.

    Now thats Professional.
    My kind of work.
  26. Replies
    13
    Views
    2,178

    Whats your TD across the evaporater?

    Whats your TD across the evaporater?
  27. Thread: How old were you

    by cboe
    Replies
    4
    Views
    693

    I was 21 right out of the ARMY. did it all, and...

    I was 21 right out of the ARMY. did it all, and am now retired
  28. very sad my thoughts and prayers go out to the...

    very sad my thoughts and prayers go out to the family.
    I am very lucky, the worst thing that ever happened to me was a fall off of a ladder of 18 ft. my shoulder still hurts after 20 years.
    we need...
  29. Replies
    27
    Views
    3,486

    thoughts on long hair

    If I were a resturant owner I would concerned about long hair around food prep area.ie. salad bars.itc.
  30. Replies
    6
    Views
    991

    whats my tonage

    I second that,CALL A CERTIFED TECH.
  31. Replies
    14
    Views
    2,069

    dito! behind the evap. on the wall or celling.

    dito! behind the evap. on the wall or celling.
  32. Replies
    25
    Views
    2,374

    I am retired and still enjoy the wealth of...

    I am retired and still enjoy the wealth of information that is here on this site. appreciate you all.:putergreet:
  33. Replies
    16
    Views
    2,609

    maby they recoverd the R-22. and sold it....

    maby they recoverd the R-22. and sold it. :putergreet:
  34. Thread: duct board

    by cboe
    Replies
    22
    Views
    1,901

    I agee sheet metal is better, but I think...

    I agee sheet metal is better, but I think ductboard is here to stay. I have install a lot of it.
  35. Thread: Chest freezer

    by cboe
    Replies
    11
    Views
    1,061

    In my area Sears is closing the store. they are...

    In my area Sears is closing the store. they are selling comb. reff. freezer at 70* off. I am thinking about getting one before they are all gone.
  36. Thread: R-22 replacement

    by cboe
    Replies
    24
    Views
    3,705

    R-22 replacement

    I did a search and could,t find a good replacement for R22. what do you folks think about MO99 R-438A for a drop in fo R-22? anyboby having good results with it?
  37. Replies
    20
    Views
    2,447

    I am glad I am retired! you young guys can have...

    I am glad I am retired! you young guys can have it.:cheers:
  38. Replies
    37
    Views
    2,674

    in 50 + years I have never seen it eather.

    in 50 + years I have never seen it eather.
  39. Replies
    7
    Views
    1,709

    Looks like a nightmare to me. if you have been in...

    Looks like a nightmare to me. if you have been in this business for a few years you will run into that kind of stuff at onetime or another.
    where did you install the suction filter? I did't see one.
  40. Thread: High pressure

    by cboe
    Replies
    33
    Views
    2,008

    is the condensor clean? just a thuought.

    is the condensor clean? just a thuought.
  41. Replies
    25
    Views
    2,023

    Poll: I have had my share of run ins with enginers. but...

    I have had my share of run ins with enginers. but there are some real ones out there too. I have learned a lot from them, and they have learned from me too. as with a lot of you folks also.
  42. Thread: crystal tips?

    by cboe
    Replies
    2
    Views
    1,030

    Looks like your stuck!!

    Looks like your stuck!!
  43. Thread: Air Condition

    by cboe
    Replies
    18
    Views
    1,232

    maybe the timming belt is broke!!

    maybe the timming belt is broke!!
  44. Thread: Ride Along Advice

    by cboe
    Replies
    68
    Views
    5,369

    don't show with a hangeover!

    don't show with a hangeover!
  45. Replies
    2
    Views
    703

    there is a wealth of information on this forum....

    there is a wealth of information on this forum. its like setting in a class room with realy good teachers. ask away.
  46. Replies
    16
    Views
    2,455

    I have ran into this many times. TXV iceing up....

    I have ran into this many times. TXV iceing up. the only way I could remove the moisture is change the oil, and install a hi capasity drier and suction filter. and clean the TXV.
  47. Replies
    10
    Views
    1,030

    maby thats why i lost some of my hearing. too...

    maby thats why i lost some of my hearing. too meany years knocking duct togeater using pitt. mich.
    guys use your ear plugs, and protect your lungs. an old timmer in the HVACR trade. 50+ years and it...
  48. I watched it all tonight. intresting.

    I watched it all tonight. intresting.
  49. I used to work for a guy, and every time I...

    I used to work for a guy, and every time I screwed up he would tell me if you dont screw up you are not doing nothing. he was a wise man, and I was just a youngster. that was a long time ago, and I...
  50. Replies
    317
    Views
    31,500

    Now retired from being in the trade for all most...

    Now retired from being in the trade for all most 50 years, 35 years as an employer, and I can tell you that not much has changed. even in my time we had problems finding people willing to start at...