Search:

Type: Posts; User: REEFERMAN4U

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    16
    Views
    2,912

    Running on 1 cylinder. Black oil is al/mag powder...

    Running on 1 cylinder. Black oil is al/mag powder from rod. Time for new pump. K bodies are tough puppies. Before installing new k, stand it up on crank end for a minute to fill slinger cup at end of...
  2. Replies
    15
    Views
    1,645

    That box size in FL would normally be 3/4 hp. Go...

    That box size in FL would normally be 3/4 hp. Go with the 1 hp (with accumulator) and defrost clock if none exists. Convert to 404 due to phase out of 22. .03c
  3. Replies
    3
    Views
    738

    2"

    2"
  4. Replies
    11
    Views
    949

    Is there an oil separator? Is the compressor...

    Is there an oil separator? Is the compressor above the evaps?Suction accumulator full of oil, blocked return hole in u bend? INPUT INPUT
  5. Coke is a Joke. (service) They do have really...

    Coke is a Joke. (service) They do have really cool red trucks. ha
  6. Replies
    8
    Views
    795

    Defrost timers can be a bit loud when the plastic...

    Defrost timers can be a bit loud when the plastic gears grind. ??
  7. For locations such as cooks line ,I pull the...

    For locations such as cooks line ,I pull the condensers and remote to cooler location. Then the recovery is much faster and soooooooo much easier to service..03c
  8. Thread: WTF?

    by REEFERMAN4U
    Replies
    59
    Views
    12,314

    We can only hope his ship will return soon and...

    We can only hope his ship will return soon and take his back to Uranus.
  9. I leave my 134a cylinders at the shop for auto...

    I leave my 134a cylinders at the shop for auto only use. Hot shot or 414a is the best drop in for 134a. It floods back nicely and compressors love it . Besides it comes in a pretty blue container.
  10. I did this as well on an old case. Installed an...

    I did this as well on an old case. Installed an oversized liquid drier in the vertical down flow position, this compensates for no receiver tank. .04c
  11. Replies
    5
    Views
    692

    At McDonalds, we overlay 1/4" DP on reversed...

    At McDonalds, we overlay 1/4" DP on reversed seams. Heavy delivery carts from Martin Brower curl up anything thinner..03c
  12. If the problem is wax, the pig will compact the...

    If the problem is wax, the pig will compact the wax into a solid jam. I have only had success with small pieces of debri being pushed. .03c
  13. Replies
    23
    Views
    1,664

    Honesty and reliability. I have had some accounts...

    Honesty and reliability. I have had some accounts for over 20 years and never take them for granted. .03c
  14. Replies
    30
    Views
    2,284

    Lay an 8lb bag of ice on top and it will do a...

    Lay an 8lb bag of ice on top and it will do a fine job. This is the earliest form of refrigeration.
  15. Replies
    19
    Views
    1,518

    Check the condensers outside, most reliable...

    Check the condensers outside, most reliable installers will have ball valves for isolating different coils. .04c
  16. Replies
    11
    Views
    1,077

    Aussies and Kiwis know their beer stuff!

    Aussies and Kiwis know their beer stuff!
  17. Is this the same freezer you mentioned in 05?...

    Is this the same freezer you mentioned in 05? Your restaurant needs professional help.
  18. Replies
    11
    Views
    2,030

    Replace Compressor

    Replace Compressor
  19. Replies
    8
    Views
    859

    460v ? Should make ice twice as fast.

    460v ? Should make ice twice as fast.
  20. TX problem. Is there a moisture indicator in the...

    TX problem. Is there a moisture indicator in the glass? If ok slightly torch tx bulb and look for change in pressure.
  21. Replies
    4
    Views
    621

    Remove old pan and take to metal shop for...

    Remove old pan and take to metal shop for duplication,much faster on old equip.
  22. 15% on copper 45% on steel and brass

    15% on copper 45% on steel and brass
  23. Thread: Invention!

    by REEFERMAN4U
    Replies
    16
    Views
    1,770

    Some machines need the heat in supply water for...

    Some machines need the heat in supply water for ice release in harvest. .04c
  24. Thread: Hoshizaki

    by REEFERMAN4U
    Replies
    15
    Views
    1,417

    9 out of 10 times / low pressure = freeze up

    9 out of 10 times / low pressure = freeze up
  25. Replies
    6
    Views
    935

    I mainly service McDonalds restaurants in N...

    I mainly service McDonalds restaurants in N Florida. Very Busy all year. "The Happy Meals Must Flow" Haa
  26. Replies
    26
    Views
    6,424

    What condition is the evap coil in? The "off...

    What condition is the evap coil in? The "off cycle defrost" will not do the job if the coil is in poor shape and has low TD.
  27. Replies
    6
    Views
    935

    The sulfur candle is a stick coated with sulfur...

    The sulfur candle is a stick coated with sulfur and looks like incense. The smoke turns white in an ammonia stream, and the leak can be followed back to the source. .03c
  28. Replies
    10
    Views
    1,112

    At least you got paid. I am still waiting for...

    At least you got paid. I am still waiting for Mani payment from Feb warranty repair. hoshi and scots 30 day payment. I no longer push manis as a replacement machine. .03c
  29. Replies
    7
    Views
    1,060

    The "Block Ice & Fan System" ? ha

    The "Block Ice & Fan System" ? ha
  30. Replies
    62
    Views
    6,154

    What was the original question here?? Iz be...

    What was the original question here?? Iz be losted
  31. Replies
    21
    Views
    2,960

    Undercharge.. Add 3 to 4 lbs. On to next call.

    Undercharge.. Add 3 to 4 lbs. On to next call.
  32. Replies
    7
    Views
    1,762

    No Valvie, No Pumpie. ha

    No Valvie, No Pumpie. ha
  33. Replies
    17
    Views
    9,791

    I may be wrong (happens daily) but auto 134a with...

    I may be wrong (happens daily) but auto 134a with large fitting contains oil in the cylinder. since the auto oil charge is so critical and some is usually lost from leaks. The 134a with 1/4f fitting...
  34. Replies
    10
    Views
    1,366

    I have used uv dye for many years. great for...

    I have used uv dye for many years. great for finding leaks in coils and windy locations where sniffers dont work. My new LED flashlight will also show the yellow color. if not sure check the oil...
  35. Replies
    18
    Views
    1,898

    put a 24 hr chart on it and see the exact changes...

    put a 24 hr chart on it and see the exact changes in temps. very handy tool when others have access to the breakers..03c
  36. Replies
    38
    Views
    3,608

    414 is a great replacement for 12, 134 . Just...

    414 is a great replacement for 12, 134 . Just reduce the charge 20%. It floods back early and keeps the compressor cool and happy. no oil change.
  37. Replies
    38
    Views
    3,608

    I agree about 134a. It is only good in automotive...

    I agree about 134a. It is only good in automotive apps. Every 134 cooler that needs gas I convert to 414, easy drop in .
  38. Replies
    38
    Views
    3,608

    They will soon run out of colors and start...

    They will soon run out of colors and start painting the drums in stripes. Ha The ref. section of my truck looks like fruit salad.
  39. Replies
    5
    Views
    823

    Due to several boxes and 1 reciever tank. It...

    Due to several boxes and 1 reciever tank. It prevented filling the condenser with liquid under low load . Worked great. Easier to balance the charge.
  40. Replies
    5
    Views
    823

    [QUOTE=parks71;1820856]A friend of mine says he...

    [QUOTE=parks71;1820856]A friend of mine says he has 1 HP remote condensor running 3 seperate bar boxes. I have never seen this set up and do not understand how it wouldnt screw up the...
  41. Replies
    18
    Views
    1,573

    I have been self employed for 27 years and have...

    I have been self employed for 27 years and have trained dozens this trade, some now have their own successful business. A few still call me for tech advice and I am happy to help. KNOWLEDGE IS FREE ,...
  42. McDonalds franchise owners will thank you for the...

    McDonalds franchise owners will thank you for the info.
  43. I have tried to do the same with the door...

    I have tried to do the same with the door heaters, and no luck. So far every one has to be ordered to length. Bummer.
  44. Replies
    18
    Views
    1,573

    Pitch suction downward for oil return. No traps....

    Pitch suction downward for oil return. No traps. must have solenoid for pump down and accumulator tank for slugging.
  45. Replies
    6
    Views
    1,085

    [QUOTE=refer1;1805769]I have an Reach down refer...

    [QUOTE=refer1;1805769]I have an Reach down refer box that was used as a "Coca-Cola" service box made by Cornelius and It has a bad compressor. And what I wanted to know only because I have a cylinder...
  46. Replies
    10
    Views
    796

    WHAT!! you mean we are not allowed to hit...

    WHAT!! you mean we are not allowed to hit customers? But thats the fun part. Haa
  47. Thread: Beacon II

    by REEFERMAN4U
    Replies
    13
    Views
    1,559

    Any training class is worth the effort, not to...

    Any training class is worth the effort, not to mention the free tech manuals. My chain accounts have Beacon 1&2 and Master Built EEVs. Lee
  48. Replies
    29
    Views
    6,609

    Most of the walk-in coolers I service do have...

    Most of the walk-in coolers I service do have tanks. It is just an option for med temps but can protect the pump. Lee
  49. Replies
    29
    Views
    6,609

    Reversing just broke the jammed rod(s) free ....

    Reversing just broke the jammed rod(s) free . Replace compressor and you did not say if the unit has an accumulator. If not I would suggest installing one since the store employees like to block off...
  50. Replies
    9
    Views
    881

    If the sightglass is full it might be weak power...

    If the sightglass is full it might be weak power head. Add heat to thermo bulb and see if suction pressure increases.If the TXV has a screw on PH then change just that . .03c