  1. Wow...I do have many frowns :( but at least I...

    Wow...I do have many frowns :( but at least I now understand why 3 retailers said they would not put an insert in a factory built, and 3 said it was fine. Heartman, as always, made some really good...
  2. Replies
    2
    Views
    461

    Aprilaire 600M New Pipe Noise

    Hello,
    We have a York modulating furnace and an Aprilaire 600M humidifier. We had problems with the install of the furnace a couple of years ago (this form was a great resource), but now we have an...
  3. Regency Wood Insert vs. Heatilator Accelerator

    Hello,
    We have a small zero-clearance/factory built fireplace from the mid 1980s. The chimney is in good repair, with no rust or pitting. The problem is this fireplace doesn’t add any heat to the...
  4. Replies
    65
    Views
    8,722

    Well, I'm keeping my fingers crossed. So far,...

    Well, I'm keeping my fingers crossed. So far, the furnace has worked since they replaced the board and the venter motor. When I asked about the transducer, I got a puzzled look on the tech's face,...
  5. Replies
    65
    Views
    8,722

    @freezeking2000: this is an upflow furnace I...

    @freezeking2000: this is an upflow furnace

    I didn't realize that the switches would reset themselves. Last night was the first time it reset itself.

    I want to get the venting fixed...
  6. Replies
    65
    Views
    8,722

    @spymoocow: thanks for the thoughts on the gas...

    @spymoocow: thanks for the thoughts on the gas pressure - I will have them look at it in the morning. Regarding the temperature rise, they took it last might and the rise was originally 76 to 107,...
  7. Replies
    65
    Views
    8,722

    Thanks for all the responses. I was able to get...

    Thanks for all the responses. I was able to get the tech back in tonight, since he was still close by. I will have to wait for the senior tech in the morning when they will likely change the...
  8. Replies
    65
    Views
    8,722

    Yes, they checked the venting, and it looked...

    Yes, they checked the venting, and it looked fine. There is a small 10 inch section between 2 elbows that is probably too close to level for my comfort, so they said they will change that out if the...
  9. Replies
    65
    Views
    8,722

    He made sure the burners were working, there were...

    He made sure the burners were working, there were no CO2 leaks, and did spend some time watching the blower ramp up, etc. So he did spend some time watching the setup. I don't think they'll be able...
  10. Replies
    65
    Views
    8,722

    You won't beleive this, but we already have the 5...

    You won't beleive this, but we already have the 5 read flashing lights and cold air blowing only 20 minutes after the tech left!! This is after a new hi limit switch, control board and venter...
  11. Replies
    65
    Views
    8,722

    Thanks for all of your help last night! To keep...

    Thanks for all of your help last night! To keep you updated, the owner of the HVAC company called this morning and said that we need to change the control board and venter motor. A very...
  12. Replies
    65
    Views
    8,722

    Well, it is still a mystery. When he first got...

    Well, it is still a mystery. When he first got in, with the red lights flashing, he first checked the wiring connections, and found it odd that the aux limit switch had no power, but it had...
  13. Replies
    65
    Views
    8,722

    Pipes are about 17 feet, with 5 elbows + the 2...

    Pipes are about 17 feet, with 5 elbows + the 2 elbows in the vent pipe outside of the exterior wall. This looks OK from what I can see in the manual. Could have been a straight run, with only 1...
  14. Replies
    65
    Views
    8,722

    Nothing is ever simple...even after a bunch of...

    Nothing is ever simple...even after a bunch of research, consumers just never know when the job is done right. This HVAC company I signed with and that is doung the servicing is on York's list of...
  15. Replies
    65
    Views
    8,722

    Thanks! is the auxillary switch the same as the...

    Thanks! is the auxillary switch the same as the high limit switch? and when you say the revision is the communicating board, was that meant for john regarding the newer models and teh flashing...
  16. Replies
    65
    Views
    8,722

    Thanks for the quick responses. I've rechecked...

    Thanks for the quick responses. I've rechecked the drain lines, and they are not full of water, and they do not sit in water it empties into the main drain, and sits a few inches above the water...
  17. Replies
    65
    Views
    8,722

    Arrgh! The contractor came back again last week...

    Arrgh! The contractor came back again last week and was confident that it was the hi-limit switch. He said it was impossible to tell if it was the switch or the board, but since they haven't had...
  18. Replies
    65
    Views
    8,722

    Thanks! The drain line from the furnace is...

    Thanks! The drain line from the furnace is veneted seperately, although it does tie in later to the drain tube of the humidifier and AC coil. I'll mention this to him on Monday. The problem...
  19. Replies
    65
    Views
    8,722

    My installer is pretty confident that it is...

    My installer is pretty confident that it is either a high limit switch problem, or a board problem. Either way it will be covered under warranty, but I hope this fixes the problem.

    No one on...
  20. Replies
    65
    Views
    8,722

    Yes, I change my Merv 10 or 11 filter at least 3...

    Yes, I change my Merv 10 or 11 filter at least 3 times per year (I listen to you guys, and gals, on this forum), and the installer said that the filter was fine.

    The horizontal runs have only a...
  21. Replies
    65
    Views
    8,722

    York with NO HEAT

    We had a York Affinity 9.C Series Modulating Furnace (80,000BTU) installed in March of 2008, and had no problems last winter. Today, we had no heat and the circut board had 5 red flashes repeating. ...
  22. Replies
    14
    Views
    1,427

    @ all you hardworking techs: Thanks for all of...

    @ all you hardworking techs: Thanks for all of the help guys, this forum is the best!

    @doc holiday: Our Lifebreath HRV has an interchangeable core, so it can be converted to an ERV - but we were...
  23. Replies
    14
    Views
    1,427

    Sounds like I'm back to needing the humidifier to...

    Sounds like I'm back to needing the humidifier to run longer than the mod furnace currently does.

    If I upgrade to the IAQ, will the Aprilaire 600M humifidfier be able to run independently from...
  24. Replies
    14
    Views
    1,427

    No, we don't have an outdoor temperature sensor...

    No, we don't have an outdoor temperature sensor (I don't know if one can be hooked up to the TH8321 T-Stat).

    I'll have the installer check the water flow orifice at the next tune-up, and...
  25. Replies
    14
    Views
    1,427

    Thanks beenthere. If by "orfice size" you mean...

    Thanks beenthere.

    If by "orfice size" you mean the size of the opening on the cold air return where the humidifier sits, then it is already cut out to fit the entire humidifier area (when I take...