Search:

Type: Posts; User: jonny in La

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    4
    Views
    1,669

    Source Refrigeration.

    How are they to work for.
  2. Replies
    0
    Views
    496

    supermarket work

    supermarket tech looking to stay in ohio anybody got any leads
  3. Replies
    17
    Views
    1,714

    30 an hour after a few years all I can say is you...

    30 an hour after a few years all I can say is you better have another job lined up, to get to that wage you need years of experience but if you stick with it apply yourself dont undercut yourself...
  4. Thread: Deem

    by jonny in La
    Replies
    5
    Views
    1,082

    at least theres nothing negative thanks Berger

    at least theres nothing negative thanks Berger
  5. Thread: Deem

    by jonny in La
    Replies
    5
    Views
    1,082

    Deem

    Anybody work for this company before theyre out of Indianapolis Indianna
  6. Replies
    8
    Views
    1,609

    behold ye ole cornholenelius

    behold ye ole cornholenelius
  7. Replies
    28
    Views
    1,935

    check your superheat and make sure that the drain...

    check your superheat and make sure that the drain to all evaps are trapped.
  8. the reason why you do that is its better in a...

    the reason why you do that is its better in a warm enviroment and it'll help keep a better product temp and you wont need a defrost timer
  9. temperature control

    go and get an adjustable stat ranco or penn it should have a pigtail for the sensing bulb stick it in the coil set your c.o at 18-20 your ci at 40 degrees if the unit runs right and is charged right...
  10. reach in on cook line

    I learned that if you sit back and watch the line when its busy you'll learn something. Heres a clue are the cooks leaving the doors or drawers cracked think about it for a minute Ill give an answer...
  11. Replies
    27
    Views
    2,555

    you could go into automation and probably trane...

    you could go into automation and probably trane carrier mcquay etc... you'd be in the field and working with hvac..... with your electrical degree and allllllll:D:D:D:D:D:D:D
  12. Replies
    5
    Views
    988

    when i say variable its actually a digital you...

    when i say variable its actually a digital you know the new copeland any how its getting worked out thanks guyzzzz.:D:D:D
  13. Replies
    30
    Views
    2,512

    you can always spot managers that have no...

    you can always spot managers that have no experience either dealing with techs or customers its a skill just like being a tech takes a lot of time to develope.Also bet you theyre the kind that talks...
  14. Replies
    5
    Views
    988

    hill phoenix rack

    service information packet on hill phoenix rack split header with variable capacity copeland on medium temp side any help would be appreciated.
  15. Replies
    11
    Views
    1,686

    talk to your parts house and ask for the...

    talk to your parts house and ask for the performance curve or you do the ol compressor efficiency if you can find out how many gpms its pumping.
  16. Replies
    6
    Views
    1,071

    if there was such a shortage how come they werent...

    if there was such a shortage how come they werent recruiting when it was slow.
  17. Replies
    37
    Views
    2,610

    i use to work with a guy who was a contractor he...

    i use to work with a guy who was a contractor he moved to La and they have him wrapped up sorry to say it but thats where all the jobs are at due to oil exploration if your interested in going there...
  18. Replies
    1
    Views
    671

    put in for a position as a install helper...

    put in for a position as a install helper guaranteed to learn it ground up the best way in my book your not going to make tech pay but its a start.
  19. Replies
    10
    Views
    672

    hey cracker can I get it to new target store has...

    hey cracker can I get it to new target store has em and I dont want to stumble around in the dark
  20. Replies
    7
    Views
    773

    if its in a steel plant believe you got holes in...

    if its in a steel plant believe you got holes in your flexible hose go get a D TEK you'll be glad you did is it running 124.
  21. Replies
    4
    Views
    1,760

    yes I did thanks boys!!!!!

    yes I did thanks boys!!!!!
  22. Replies
    4
    Views
    1,760

    enthalpy chart

    where can I get an enthalpy chart for air any help would be greatly appreciated.
  23. Replies
    28
    Views
    2,114

    i'd say fine if he's gonna give you approximately...

    i'd say fine if he's gonna give you approximately 18% of the job this is what air now companies do if he's gonna pay you less i'd say no way and at that % you can easily make fifty and up
  24. Thread: Headmaster

    by jonny in La
    Replies
    10
    Views
    1,045

    that was in Ohio or you dont consider that North

    that was in Ohio or you dont consider that North
  25. Thread: Headmaster

    by jonny in La
    Replies
    10
    Views
    1,045

    rule of thumb I always use on smaller systems...

    rule of thumb I always use on smaller systems used in restauraunts of course not supermarkets add 1lb additionally past clear sightglass and you'll be charged correctly for the operation of a wic and...
Results 1 to 25 of 88
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event