Search:

Type: Posts; User: zipscrew

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    611
    Views
    102,896

    i was told by dispatch to go to a business for a...

    i was told by dispatch to go to a business for a no cool. it was a warehouse type building they moved in a few monthes before. it was a rooftop so i get my ladder out climb up there and guess what?...
  2. ?????

    i know it was a big investment and all, but you aren't really telling us anything. i would drop the drama and get on with the story. i do think excruciating is a code violation.
  3. Replies
    3
    Views
    512

    mini split

    we use fujitsu
  4. lennox modulating

    so how many low voltage wires are we talking? did the number go up or down to stat mostly at 4 here.
  5. Replies
    4
    Views
    1,212

    you would think that these leaks would show up on...

    you would think that these leaks would show up on nitrogen check. does lennox have anything to say about this. by the way thanks for your comments
  6. Replies
    4
    Views
    1,212

    lennox XC15 / lennox coil

    we seem to be finding a few condensors that have leaked out all the charge but when pumped up there appears to be no leaks. anybody have same problem
  7. Replies
    85
    Views
    6,812

    zipscrew

    could he have been flushing the lines? maybe going to 410A
  8. Replies
    9
    Views
    1,848

    lets see a picture of the pipe where it comes out...

    lets see a picture of the pipe where it comes out of the roof
  9. Thread: coleman evcon

    by zipscrew
    Replies
    8
    Views
    879

    coleman evcon

    i installed coleman evcons in alot of houses, the other day a homeowner called to report gas leak. the gas company was called and was there when i arrived. the whole house was filled with gas and...
  10. Replies
    15
    Views
    1,247

    one more thing

    you could have done better yourself BUT you can't can you. your not a contractor you can't take out a permit you might not even have a comp card. don't mean to offend you
  11. Replies
    15
    Views
    1,247

    new construction

    are you saying it didn't pass inspection or that they didn't take out permit or are you saying its all within code but not up to some personal standard?
  12. Replies
    15
    Views
    1,247

    problem

    so if you could have done better yourself what would you have done and what would you charge. can you compete? some of you service guys are always running your mouth about installs it's the same...
  13. Thread: Replace The

    by zipscrew
    Replies
    12
    Views
    3,087

    ductless

    i've only seen one of these. house was made totally out of cement. under the house was a crawl space maybe 25 by 40 and four feet tall. had one duct stubbed in to pressurize the room and holes...
  14. Replies
    24
    Views
    2,053

    its only me

    i'm the guy who used to show up with the other four guys. the electric guy, the pipe fitter, the delivery guy and me the sheet metal guy. now its just me. so i'm the lonely guy
  15. Replies
    14
    Views
    1,405

    was that a joke about periods and comas? do you...

    was that a joke about periods and comas? do you get a monthly period?
  16. Replies
    52
    Views
    3,425

    RETURN AIR

    did i read that right he cut in a grill in the return shoe or drop? thats against code in my area.
  17. Replies
    88
    Views
    6,875

    supply runs

    why would these need to be insulated?
  18. wires

    can new wires be pulled to the stat? 2 stage takes more wires. this maybe why you have the set up you have.
  19. Replies
    21
    Views
    13,213

    so you are building your entire system around one...

    so you are building your entire system around one componet that is way oversized for your house and should not be there. so somebody made a mistake in the condensor, so instead of fixing the mistake...
  20. Replies
    6
    Views
    884

    i believe fujitsu wants you to add only using a...

    i believe fujitsu wants you to add only using a scale determined by length of linesets
  21. Thread: brake

    by zipscrew
    Replies
    1
    Views
    572

    ever try northway machine in iowa? sell new and...

    ever try northway machine in iowa? sell new and used
  22. Replies
    38
    Views
    8,756

    install

    wouldn't it be something if the clown took 2 days to do it.
  23. Replies
    11
    Views
    3,418

    location

    like most installs they most likely were instructed by homeowners to put it there, as every other inch of space is reserved for future plans.
  24. Thread: lennox pulse

    by zipscrew
    Replies
    37
    Views
    5,033

    pulse

    took out another pulse today, they are the heaviest damn things.
  25. Replies
    2
    Views
    876

    am tired of nailing up panning. has anybody had...

    am tired of nailing up panning. has anybody had real good success with a electric stapler?
Results 1 to 25 of 41
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event