07-12-2008, 12:27 AM
Thread: Bryant HVAC System is Frozen
by hiflow- Replies
- 20
- Views
- 687
system frozen
Running the blower to defrost a coil may or may not be a good idea.The melt water may overflow the condensate pan causing collateral damage. If using blower to melt ice watch for signs of melt water...
-
07-01-2008, 08:08 PM
Thread: chlorine tablets
by hiflow- Replies
- 14
- Views
- 1,671
pantabs
if not pantabs what do you suggest ?
-
07-01-2008, 08:05 PM
Thread: system working overtime?
by hiflow- Replies
- 16
- Views
- 763
system working overtime
does the outside unit continue to run when the indoor unit stops ?
-
gallo gun
thanks for the replies Mark, Gas, Lost art and Beachtech. Really like that little vac, Beachtech. Showed it to Big Al sr. team member who's considering the gallo gun. His method for dealing with a...
-
06-28-2008, 12:01 PM
Thread: HVAC repair at night?
by hiflow- Replies
- 37
- Views
- 1,725
repair at night
LOL too, HVAC techs , hero-geniuses that we are, find ways to overcome all obstacles day or night, bending, but never breaking the rules of physics.
-
06-27-2008, 08:05 PM
Thread: Infrared thermometer
by hiflow- Replies
- 8
- Views
- 826
infrared thermometer
I vote the wow factor. Plus it's worth it to show the customer the difference between exit air and return air temp.
-
06-27-2008, 08:00 PM
Thread: manifold gauge questions
by hiflow- Replies
- 5
- Views
- 1,051
gauge questions
definitely purge
-
gallo gun
at our shop we sometimes debate on whether to pressurize the drain from outside or inside can anyone help us out?
-
06-18-2008, 09:50 PM
Thread: cleaning tools
by hiflow- Replies
- 15
- Views
- 875
cleaning tools
WD 40 works great especially when combined with a wire brush and some eelbow grease
-
06-18-2008, 07:34 PM
Thread: AC seems to run a long time
by hiflow- Replies
- 8
- Views
- 695
runs a long time
Something is amiss there Sweet GT don't waste time before getting this checked out. Allowing this system to operate may do damage to the compressor.
-
06-12-2008, 08:01 PM
Thread: 10 SEER vs. 13 SEER
by hiflow- Replies
- 2
- Views
- 487
10 seer vs. 13 seer
avoid the mismatch 98jeep don't sacrifice capacity and efficiency for a lower cost job encourage the homeowner to protect his investment and avoid future problems
-
06-07-2008, 06:02 PM
Thread: PVC/Condensation pipe blowing cold air
by hiflow- Replies
- 16
- Views
- 1,102
pipe
This may have beeen an attempt to put a clean out access into the condensate drainage system whereas a snake could be introduced through this pipe to unclog the drain at either the bottom of the...
-
06-07-2008, 05:43 PM
- Replies
- 5
- Views
- 965
replacement
Replacing only the condenser will create a mismatched system. Efficiency will fall short and energy consumption will probably be higher. Replace the entire system and get the full benefit of reduced...
-
06-05-2008, 10:06 PM
Thread: Fasco 277V single phase question
by hiflow- Replies
- 4
- Views
- 618
fasco 277v single phase
are these heat pumps, Maxster? By the way ,careful with that 277, buddy it's crazy powerful
-
06-05-2008, 09:57 PM
Thread: mismatched
by hiflow- Replies
- 16
- Views
- 955
mismatched
what makes these mismatches such a shame is the loss of efficiency and waste of energy these systems produce
-
06-03-2008, 12:57 PM
Thread: A/C Question
by hiflow- Replies
- 13
- Views
- 1,166
a/c question
welcome to the real world cuervo. the way to get knowledge is to admit you need to know listen to the pro advice in these forums and add to your toolbox
-
06-03-2008, 12:43 PM
- Replies
- 18
- Views
- 2,593
installing hard start capacitor
a homeowner should consider the benefits of repairing this system correctly reliability efficiency and maintaining the value of the home