  1. Thread: Combo sensors

    by mechinc
    Replies
    3
    Views
    829

    Combo sensors

    Anyone know of a temp/humidity/diff pressure combo sensor or meter
    or panel available?

    I have a operating room that I need to control all 3 conditions.
  2. Replies
    2
    Views
    889

    Microset II and MSTP Looking to calibrate the...

    Microset II and MSTP
    Looking to calibrate the humidity value.
    It is 10% off.
    I can take the AV-102 and put an offset in programming for control purposes but the display still reads wrong.

    TIA
  3. Replies
    2
    Views
    889

    Alerton Microset

    I have a Microset with Temp and Humidity display.
    The temp is AI-0 to AV point but the humidity is straight to AV point.

    How can I calibrate it so the display can show the
    right humidity...
  4. Thread: Alerton-WEB

    by mechinc
    Replies
    11
    Views
    1,230

    What are you talking about? I have the Envision...

    What are you talking about?
    I have the Envision for Bactalk software...
  5. Replies
    9
    Views
    749

    Do you have your firewall enabled during install?

    Do you have your firewall enabled during install?
  6. Thread: Alerton-WEB

    by mechinc
    Replies
    11
    Views
    1,230

    I do not have a copy of the original job. If I...

    I do not have a copy of the original job.

    If I rebuild all the displays in the BCM-ETH with Envision,
    How do I pass those displays to the BCM -WEB?

    TIA
  7. Thread: Alerton-WEB

    by mechinc
    Replies
    11
    Views
    1,230

    Alerton-WEB

    I have a site with BCM-ETH with BCM-WEB but no workstation.
    There are no backups but I need to modify the displays.
    I have Envision for Bactalk 2.6 on my laptop so I can modify
    the programming and...
  8. Replies
    7
    Views
    749

    Check out CDW... Eaton Management Card Contact...

    Check out CDW...

    Eaton Management Card Contact / RS232 Serial - remote management adapter
    Mfg. Part: 66104 | CDW Part: 1780442 | UNSPSC: 43222633

    You add this card to one of their small...
  9. Thread: Teletrol

    by mechinc
    Replies
    0
    Views
    484

    Teletrol

    We have:

    Teletrol “The Integrator” is the system used to connect to field controllers via RS232.
    The Filed controllers are Teletrol TeleSys AX.


    Anyone pulled this system back or converted to...
  10. Replies
    9
    Views
    1,777

    anyone with a driver or any news getting this...

    anyone with a driver or any news getting this driver?
  11. Replies
    24
    Views
    1,955

    Cause: The NCM by default syncs its time off...

    Cause:
    The NCM by default syncs its time off the 60Hz power frequency. In this case, the job site had lost power several times and switched over to an emergency UPS which caused the time problems. ...
  12. Replies
    24
    Views
    1,955

    So it is a NCM that has a modem connected to it,...

    So it is a NCM that has a modem connected to it,
    which is dialed-up by a workstation.

    Are there any other workstations on the network?

    What are device subnet and node IDs?

    To change the...
  13. Replies
    2
    Views
    638

    We have both the NCM COAX card and the COAX/ETHER...

    We have both the NCM COAX card and the COAX/ETHER combo cards...
  14. Thread: Trane

    by mechinc
    Replies
    17
    Views
    1,648

    I seen some posts regarding flashing the...

    I seen some posts regarding flashing the MP581s...
    Will this help or hurt?

    How do I determine what version the controller is at
    and what version I have?
  15. Thread: Trane

    by mechinc
    Replies
    17
    Views
    1,648

    It was an existing trunk and we added the 3rd...

    It was an existing trunk and we added the 3rd party in the middle.
    I performed the rebuild function and other MP581s installed but this one just won't. I will try to check trunk but it is funny that...
  16. Thread: Trane

    by mechinc
    Replies
    17
    Views
    1,648

    Anyone???

    Anyone???
  17. Replies
    13
    Views
    2,361

    Yes, UI into the NAE and double-click the NAE....

    Yes, UI into the NAE and double-click the NAE.
    Just Enable the Bacnet exposed.

    Then reboot the NAE.

    Then you should be able to discover the device instance
    and change it to what you want.
    ...
  18. Thread: Trane

    by mechinc
    Replies
    17
    Views
    1,648

    We tried to unassign and save it. Then clear RAM...

    We tried to unassign and save it.
    Then clear RAM and Reset.
    Then let the BCM discover.
    Then tried to reassign.
    The controller comm shows UP.
    I am using a MP581 Summary graphic.
    At first, the...
  19. Thread: Trane

    by mechinc
    Replies
    17
    Views
    1,648

    Trane

    We added a 3rd party LON device to a tracer Summit
    system using Rover and the workstation.
    Now an existing MP581 shows Incomplete Bindings.
    There is another MP581 right next to this one
    and it...
  20. Thread: Alerton

    by mechinc
    Replies
    3
    Views
    740

    Thanks...I will try and let you know.

    Thanks...I will try and let you know.
  21. Thread: Alerton

    by mechinc
    Replies
    3
    Views
    740

    Alerton

    I have a site that has a Alerton BTI with VLCs, older ViewPort, VLC1188C, and a few Niagara controllers on MSTP.
    The bactalk workstation is running 2.6
    I am getting a segmented not supported on...
  22. Thread: Trane

    by mechinc
    Replies
    3
    Views
    408

    Yes, I think using CPL is the only way to command...

    Yes, I think using CPL is the only way to command bacnet/ip points.
    When I use the property reference, it cannot use bacnet/ip points
    because their property is not available.
  23. Thread: Trane

    by mechinc
    Replies
    3
    Views
    408

    Trane

    I am trying to command bacnet /ip points through
    Tracer Summit. I can read them but when I map
    Output points then use the property reference
    the propoerty reference is blank.
    I can use the I/O...
  24. Replies
    0
    Views
    374

    JCI accumulator

    Does anyone have info on FEC accumulator setup?

    How about an example?

    Trying to setup but only shows vague info on the prescale.
  25. Thread: JCI ADS

    by mechinc
    Replies
    13
    Views
    1,822

    Make sure all Java is uninstalled. Delete...

    Make sure all Java is uninstalled.
    Delete internet temp files.
    Manually Install JRE 1.5.0_6
    Disable Java update in console.

    Reboot then try...

    If it still gives same error then since it is...
  26. Thread: JCI ADS

    by mechinc
    Replies
    13
    Views
    1,822

    Need more info: What ADS version? What Java...

    Need more info:

    What ADS version?
    What Java version are you loading?
    What .net versions are loaded and what .net are you reloading?
  27. Replies
    0
    Views
    352

    FX60s with Server

    I have an account with six FX60s and Server running at 2.2

    We tried to upgrade to 3.5

    We loaded the server without a problem by checking
    use 2.2 settings box.

    We used the Upgrade Remote...
  28. Replies
    9
    Views
    579

    First, if the Carrier OPN controller is bacnet...

    First, if the Carrier OPN controller is bacnet then why are you
    using a BASRT router when you can connect the controller
    directly to NAE.

    Second, when you map out points there could be...
  29. Thread: Trane

    by mechinc
    Replies
    2
    Views
    514

    Trane

    Does anyone have any info on Trane's web based system?
    Thin client and Tracer Summit Web.

    How are the graphics stored and viewed?
    Do you need the Summit workstation?
  30. Replies
    6
    Views
    819

    I am going to check???

    I am going to check???
  31. Replies
    6
    Views
    819

    Fans are currently off of tower supply temp

    Fans are currently off of tower supply temp
  32. Replies
    6
    Views
    819

    Energy Control Sequences

    I was wondering the most energy efficient control sequences for the following:

    I have a chilled water bypass valve, chilled water pump VFD, and cooling tower bypass valve.

    Why have a chilled...
  33. Thread: Alerton

    by mechinc
    Replies
    3
    Views
    941

    I was just curious especially on the JACE side...

    I was just curious especially on the JACE side...
  34. Thread: Alerton

    by mechinc
    Replies
    3
    Views
    941

    Alerton

    Has anyone performed an Alerton BCM/TUX to
    JACE integration?

    Did you perform it with Bacnet/IP?
  35. Thread: Nexsys

    by mechinc
    Replies
    0
    Views
    488

    Nexsys

    Does anyone know of a direct replacement
    for the old Nexsys thermostats?

    SSM 4282/A21
    NXT-TSO-01
  36. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    No BCU, No frontend... This place was vacant...

    No BCU, No frontend...

    This place was vacant for several years but now
    it is being ready for occupancy.

    The Trane constant RTUs are being controlled from thermostats
    The two VAV RTUs are...
  37. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    The diagram picture on the panel states:...

    The diagram picture on the panel states:
    Thermostat Control Module with a board diagram.

    It has Inputs(temp, static, etc) and Outputs.
  38. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    NO frontend...

    NO frontend...
  39. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    Thanks for the document but on this document it...

    Thanks for the document but on this document it shows
    S1 with dip switches but on the ones that I have, there is
    NO S1 dip switch however I do have S2 and S3 dip switches.


    The boards has...
  40. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    No BCU...just 2 TCMs and a bunch of VAVs.

    No BCU...just 2 TCMs and a bunch of VAVs.
  41. Thread: Trane

    by mechinc
    Replies
    11
    Views
    1,130

    Trane

    I ran into some stand-alone Trane TCMs connected to Rooftop units.
    There are also VAV boxes on the Network.
    There is NO workstation.
    I want to know how to connect to see the RTU info...
    I have...
  42. Thread: Windows 7

    by mechinc
    Replies
    1
    Views
    459

    Windows 7

    Has anyone tested their software of windows 7?

    If so, what worked and what didn't?
  43. Thread: NAE and Pager

    by mechinc
    Replies
    9
    Views
    861

    You can send out pages through a modem or you...

    You can send out pages through a modem
    or you can send out pages via Internet.

    You can have an NAE with internal modem
    or you can add external modem and use a phone line.

    If NAE has access...
  44. You can get the LON card from Trane.

    You can get the LON card from Trane.
  45. Why are you going to use FEC controllers for? ...

    Why are you going to use FEC controllers for?

    What headend do you have?

    If not the Trane headend then you can use
    LON cards for the Trane units.
  46. Thread: JCI VMA

    by mechinc
    Replies
    5
    Views
    1,351

    The pharmacutical customer requirements prevent...

    The pharmacutical customer requirements prevent us from
    performing just an offset.
    The requirements require the actual hardware device to be
    calibrated or the range to be changed to calibrate ...
  47. Thread: JCI VMA

    by mechinc
    Replies
    5
    Views
    1,351

    JCI VMA

    I have a customer that needs to have the velocity
    pressure sensor on a VMA1420 calibrated within .08 inwc
    They have new VMAs that are .8 in wc too high.
    We can caibrate the CFM after conversion...
  48. Thread: York Modlink

    by mechinc
    Replies
    7
    Views
    1,798

    This is a different application...I don't think...

    This is a different application...I don't think you have modlink
    modules.

    The sticker on the DCU board states MSTP
    What is the other card on the bottom right with
    communication going to it...
  49. Thread: York Modlink

    by mechinc
    Replies
    7
    Views
    1,798

    What is the DCU board? Are you talking about the...

    What is the DCU board? Are you talking about the simplicity boards?

    The York Modlinc is Modbus RTU to Bacnet/MSTP,
    then you have to use a router to get it to bacnet/ip.
  50. Thread: York Modlink

    by mechinc
    Replies
    7
    Views
    1,798

    The ModLINC translator operates as a Modbus®...

    The ModLINC translator operates as a Modbus® Client providing
    an interface between a BACnet® control system and devices that
    communicate using the Modbus® RTU protocol. The ModLINC is...