  1. Replies
    54
    Views
    9,457

    Not new to rack work but need a navigation guide...

    Not new to rack work but need a navigation guide to get through novar. Any litature that can be sent would be a big help, especially hot keys
  2. Replies
    24
    Views
    1,673

    I dont know but I typically pull my own orders. I...

    I dont know but I typically pull my own orders. I dont wait to be helped. I help myself
  3. Replies
    10
    Views
    1,124

    Not sure what you mean by temp splits but I can...

    Not sure what you mean by temp splits but I can tell you there are times when I do not use gauges to calculate SH. I use coil temps. I strap a probe on the center pass of a u-bend and another one one...
  4. Thread: Adding R404a

    by gas_n_go
    Replies
    72
    Views
    4,301

    Gotta agree with the troll comment.

    Gotta agree with the troll comment.
  5. Replies
    27
    Views
    1,952

    There is a naval ship paint that works really...

    There is a naval ship paint that works really well as a coil coating with minimal heat transference loss but its pricey. Thinking outside of the box for a moment if you create a high humidity box it...
  6. That sounds low for R22. What was your ambient...

    That sounds low for R22. What was your ambient temp?
  7. What was your head pressure?

    What was your head pressure?
  8. You really need to provide more complete...

    You really need to provide more complete information for better help. The way you are presenting your problem is very confusing and we can be easily misdiagnosing it
  9. Replies
    13
    Views
    995

    Who are these reputable field sources you are...

    Who are these reputable field sources you are referring too :whistle:
  10. What do you mean by a sealed compressor? Is it a...

    What do you mean by a sealed compressor? Is it a hermetic and if so how do you know the oil has foam in it?
  11. Replies
    13
    Views
    995

    LMAO Thanks guys. He is a friend I am only...

    LMAO Thanks guys. He is a friend I am only involved as a favor to him. I have been skeptical from the get go. He use to work for Bud and this is his and his buddies design. Yes he is a bonehead but...
  12. Replies
    13
    Views
    995

    I suggested glycol as well and he refuses to go...

    I suggested glycol as well and he refuses to go that direction. Whats funny is the tap has a cold plate in it for glycol. I can chill the beer right at the head and he wont let me do it
  13. Replies
    13
    Views
    995

    I have the same understanding as you 25 max and...

    I have the same understanding as you 25 max and elbows are 5' too. This is a new install so no its never worked. I think the supply line is too small and the run is too long but I am getting good...
  14. Replies
    10
    Views
    754

    I feel your pain. Just let them know up front...

    I feel your pain. Just let them know up front what your rates are and they will go away
  15. Now lets talk about the valve plates your going...

    Now lets talk about the valve plates your going to need to change :whistle:
  16. Replies
    13
    Views
    995

    Site not allowing me to create new paragraphs in...

    Site not allowing me to create new paragraphs in my posts so here is new post with more info to limit run on paragraphs. Its a tube in tube set up. 3 1/2 od poly beer lines inside an 1 1/2" pool hose...
  17. Replies
    13
    Views
    995

    25' run with 5 90's. Has a 1HP blower. Return air...

    25' run with 5 90's. Has a 1HP blower. Return air flow is strong. 30d box temp return air temp 55d. Beer is warm (have not taken its temp Im guessing its in the 50's) Yes does foam too much too. I...
  18. Replies
    3
    Views
    339

    im running windows 7 IE8. Not sure how to test...

    im running windows 7 IE8. Not sure how to test for new paragraphs? No I have not tried it from another device
  19. Foaming might be liquid refrigerant boiling off...

    Foaming might be liquid refrigerant boiling off and that may account for the compressor noise too. You sound like your flooded to me.
  20. Replies
    3
    Views
    339

    problem making new paragraphs in posts

    For some reason I can not use my enter button to create a new line and start a new paragraph. It isn't on my end because I post on other sites. Its just here. Makes posting difficult because it...
  21. Replies
    18
    Views
    955

    Just a question because I find this stuff...

    Just a question because I find this stuff intriguing. Why cant it be designed using a plate exchanger on the water inlet line so it performs like an insta-hot system. If you have a set volume of...
  22. Replies
    13
    Views
    995

    Nobody has any input to add?

    Nobody has any input to add?
  23. Replies
    13
    Views
    995

    Forced air draft beer system

    What is a typical temp difference between supply air and return air? Right now my TD is about 25d which seems high to me
  24. I use 3/4" wall on medium temp and 1" on low temp.

    I use 3/4" wall on medium temp and 1" on low temp.
  25. Replies
    3
    Views
    666

    Quick impression of what your describing and...

    Quick impression of what your describing and giving no info on. Sounds like unit operating under capacity. Check coils, check charge, check valve performance.
  26. Replies
    22
    Views
    1,643

    Trying to understand your question here, I use to...

    Trying to understand your question here, I use to service publix a few years back. Yes they use a reheat coil to control store humidity. Unless they have changed their design.

    They generally like...
  27. Thread: Mystery leak

    by gas_n_go
    Replies
    27
    Views
    3,255

    I know I will get flamed for this admission but...

    I know I will get flamed for this admission but for small leaks I have been using nu-cal leak seal. Quick, easy, inexpensive and effective.
  28. Replies
    43
    Views
    3,589

    Sounds like it's undercharged

    Sounds like it's undercharged
  29. Replies
    43
    Views
    6,235

    Did not read through entire thread so my...

    Did not read through entire thread so my apologies if this has been covered. I always prefer controlling temp with a lpc for a few reasons.

    1. Offers compressor protection
    2. Kiss timeclock can't...
  30. Thread: Howdy Fellers

    by gas_n_go
    Replies
    19
    Views
    2,762

    Welcome Back ...

    Welcome Back

    http://www.youtube.com/watch?v=xZzEzDkeHzI
  31. Replies
    61
    Views
    6,631

    [QUOTE=VTP99;13704111] That was a good one!...

    That was a good one! :cheers:
  32. Replies
    10
    Views
    1,011

    Yup I have that suspiscion too, as a very real...

    Yup I have that suspiscion too, as a very real possibility. It would explain the bearings being washed out.
  33. Replies
    10
    Views
    1,011

    Yeah I would love to convert it to an RMCC and...

    Yeah I would love to convert it to an RMCC and take more control over the rack but its doubtfull that I can convince the customer of that.

    Im not sure how defrost is set up on this rack. Its...
  34. Replies
    19
    Views
    2,352

    Thats an oil seperator. Sorry for missguiding...

    Thats an oil seperator. Sorry for missguiding you. I have never heard of an a/c having an oil seperator.
  35. Replies
    10
    Views
    1,011

    I am more concerned with why I have lost that...

    I am more concerned with why I have lost that other comp 3 times in two weeks. Any thoughts on that?
  36. Replies
    19
    Views
    2,352

    no problem, glad I could help

    no problem, glad I could help
  37. Replies
    19
    Views
    2,352

    If your discharge line temp enetering your...

    If your discharge line temp enetering your desuperheater is 300 and where it exits that componet it reads 250 D. That would lower your SH by 50 degrees. You desuperheated your line by 50 degrees
  38. Replies
    12
    Views
    2,189

    Mine come from the coffee can of loose parts that...

    Mine come from the coffee can of loose parts that keep on my truck, thgat I strip off of condemned equipment.
  39. Replies
    19
    Views
    2,352

    What they might be doing is desuperheating the...

    What they might be doing is desuperheating the liquid to give you more usable btu's at the valve and then adding that absorbed heat back onto your suction line to boil off any liquid that night exist...
  40. Replies
    19
    Views
    2,352

    Are you sure its an oil seperator? Just a hunch...

    Are you sure its an oil seperator? Just a hunch but it might be a desuperheater that you are looking at
  41. Replies
    10
    Views
    1,011

    4D compressor failure

    I am looking to start a discussion on possible causes for a comp failure.

    This job is a nightmare. I will be going there Monday to resolve issue and I am just looking to spitball some ideas....
  42. Replies
    7
    Views
    1,194

    breaking neutral is a safety hazard. You should...

    breaking neutral is a safety hazard. You should rewire it to break hot.
  43. Replies
    64
    Views
    6,878

    Thanks for the info I collect screwdrivers and...

    Thanks for the info I collect screwdrivers and hats.

    All jokes aside why do you think Amonia is going to be a popular refrigerant in supermarkets. are you talking about using Amonia in thw...
  44. Replies
    30
    Views
    2,887

    To answer your question about flow across a...

    To answer your question about flow across a solenoid valve;

    Yes they are directional flow valves but if you have a manual stem or you keep the coil energized it will allow flow through the valve....
  45. Replies
    11
    Views
    2,212

    I have not worked with comtrol in 10 years. The...

    I have not worked with comtrol in 10 years. The only customer I had that used it was Safeway. It isnt a bad system but it is not user freindly. I found it easier to do some tasks directlt off the...
  46. Replies
    28
    Views
    1,823

    my question is why not leave it on the pump all...

    my question is why not leave it on the pump all weekend? Why disconnect it and leave it sitting in a vacume when you could of tried to hit 50 microns over the weekend instead of the 250 that you had.
  47. Replies
    12
    Views
    1,148

    My professional disclaimer: I work on large...

    My professional disclaimer: I work on large commerical refrigeration systems and do not have alot of experience with residental air handlers


    As far as this sticker goes. They dont put that...
  48. Replies
    62
    Views
    5,707

    Man I started this thread about a year ago and it...

    Man I started this thread about a year ago and it is still alive, lol.

    My intention for starting this thread was really more about safety then anything. There was another incident that happened...
  49. Switching from air cooled to water cooled

    Hi guys it's been awhile since I popped in here. I hope all is well with everyone.


    My question is this; Is it worth my time and effort to modify my H.P.'s outside unit to water cooled/heated?...
  50. Replies
    17
    Views
    1,589

    dip tubes or equalizining lines? Im under the...

    dip tubes or equalizining lines?

    Im under the impression we are dicussing three or more compressors?????