06-16-2011, 05:55 PM
Thread: Employers - Let me pick your brain!
by muchofreeo- Replies
- 317
- Views
- 24,046
I am a Supervisor for a major HVAC contractor in...
I am a Supervisor for a major HVAC contractor in NYC. It is very hard to find good apprentices. Most of the young guys just starting out want to talk on their phones all day or text their friends....
-
06-16-2011, 05:38 PM
Thread: Liebert ICOMM
by muchofreeo- Replies
- 4
- Views
- 460
Thanks. Don't have much hope, Liebert could'nt...
Thanks. Don't have much hope, Liebert could'nt answer. Seems the BMS has precedence over the unit control panel.
-
06-16-2011, 12:53 PM
Thread: Trane LIC apprentice job
by muchofreeo- Replies
- 4
- Views
- 633
You seem to know about all the companies in NYC....
You seem to know about all the companies in NYC. Bounce around a lot or have you found a place to stay?
-
06-16-2011, 11:20 AM
Thread: Liebert ICOMM
by muchofreeo- Replies
- 4
- Views
- 460
Liebert ICOMM
Large server room on BACNET. Units won't accept parameter changes. Trying to change Autorestart TD. Any changes made revert back to default. Any ideas?
-
11-21-2009, 05:49 PM
Thread: McQuay ALSD Chiller
by muchofreeo- Replies
- 3
- Views
- 686
McQuay ALSD Chiller
Looked at 3 of these today. Had only one compressor run out of 12. Looked like 3 compressors were not pumping, suct/disch were both the same. Several of them had EXV Alarms, and several of them were...
-
06-20-2008, 02:30 PM
- Replies
- 13
- Views
- 1,029
Your local supply house should have RX11 flush...
Your local supply house should have RX11 flush kits. They are a little expensive but will help clean your system.
-
06-19-2008, 06:06 PM
Thread: SH at the compressor
by muchofreeo- Replies
- 18
- Views
- 1,123
15-20 degrees s/h at compressor, higher than 25...
15-20 degrees s/h at compressor, higher than 25 and you risk overheating compressor motor. All IOM manuals do not specify s/h at compressor, only at the outlet of the evap coil. 15-20 is the best, I...
-
05-24-2007, 06:10 PM
Thread: carrier flotronic chiller
by muchofreeo- Replies
- 5
- Views
- 1,506
Thats what I'm thinking, PSIO has original...
Thats what I'm thinking, PSIO has original battery and unit is over 15 years old. I did shut power down to replace some waterside sensors, when I repowered there was no more communications. I already...
-
05-23-2007, 06:03 PM
Thread: carrier flotronic chiller
by muchofreeo- Replies
- 5
- Views
- 1,506
I have 24volts, all connections are tight. I get...
I have 24volts, all connections are tight. I get red status blinking, communication green led is blank.
-
05-23-2007, 02:21 PM
Thread: Should you be paid for call backs?
by muchofreeo- Replies
- 146
- Views
- 8,936
I spend 80% of my time following guys on...
I spend 80% of my time following guys on callbacks. The problem is either over their heads or they just don't care. If my guys get too many callbacks they wind up just doing maintenance 40 hours a...
-
05-23-2007, 02:03 PM
Thread: carrier flotronic chiller
by muchofreeo- Replies
- 5
- Views
- 1,506
carrier flotronic chiller
Have a 30HR090E500 chiller, I have a blank display and am not getting comm leds lit up. Status leds are blinking. I believe its the processor module, all fuses good. Any ideas, can't run unit.
-
05-08-2007, 05:57 PM
Thread: multiaqua blues
by muchofreeo- Replies
- 7
- Views
- 1,745
about 10 degrees subcooling, unit is a split air...
about 10 degrees subcooling, unit is a split air cooled dx system. Multiaqua puts a TXV on their evaps and you have to supply a condensing unit. Manufacturer states they rate this coil at 250cfm per...
-
05-08-2007, 03:27 PM
Thread: multiaqua blues
by muchofreeo- Replies
- 7
- Views
- 1,745
multiaqua blues
Recently installed 5 ton multiaqua dx evap mated to a 5 ton skillaire condensing unit. With unit running we are getting 40# suct/200# disch. 35dt across evap, little to no superheat. Evap only...
-
10-05-2006, 07:27 PM
Thread: Troubleshooting and Subcooling
by muchofreeo- Replies
- 18
- Views
- 1,522
Subcooling
Correctamundo, like I said subcooling is only part of your troubleshooting. But it can and does help diagnose a problem. This post can be pages long if we list all the symptoms for...
-
10-05-2006, 07:24 PM
Thread: Compressor sweating
by muchofreeo- Replies
- 15
- Views
- 2,945
Compressor sweating
Whats the delta across the barrel? You are looking for a 10 lb pressure drop across the chiller barrel. If you are not moving enough water you will start sweating back to the compressor. 20 degrees...
-
10-05-2006, 07:16 PM
Thread: Troubleshooting and Subcooling
by muchofreeo- Replies
- 18
- Views
- 1,522
Subcooling
High subcooling would let you know if you were overcharged. Low subcooling would let you know if you were undercharged. However it depends on the superheat, TD across the evap/cond etc. It can be a...
-
10-05-2006, 06:23 PM
Thread: Wine Cellar Problems
by muchofreeo- Replies
- 19
- Views
- 2,420
Wine Cellar Problems
Wine Cellar, refrigeration condensing unit indoor (R22). EMI Ductless split Evaporator section inside wine cellar. Manufacturer calls for 8 degrees superheat. System has a CPR valve, manufacturer...
-
03-07-2006, 07:55 PM
Thread: UA STAR
by muchofreeo- Replies
- 24
- Views
- 2,520
Taking it this Saturday, practice test has...
Taking it this Saturday, practice test has questions on everything. They say only 20% pass this exam. Never took the NATE, did'nt see the point. You get 30 college credits if you pass the Star. Boss...
-
03-07-2006, 07:49 PM
Thread: Mitsubishi City Multi
by muchofreeo- Replies
- 48
- Views
- 16,192
http://www.citymulti.com is the answer to all...
http://www.citymulti.com is the answer to all your questions.
-
05-19-2005, 09:01 PM
Thread: Damage to TEV/TXV from brazing?
by muchofreeo- Replies
- 23
- Views
- 2,160
To find out if you damaged the valve, all you...
To find out if you damaged the valve, all you have to do is remove the powerhead. Flip it over and feel the disc where the threads are. If it can move with your fingers it is NG. If you can't press...
-
04-21-2005, 09:39 PM
Thread: Crazy pressures/temperatures
by muchofreeo- Replies
- 19
- Views
- 1,317
TXV, 80-85 suction, 200-225 discharge. I will try...
TXV, 80-85 suction, 200-225 discharge. I will try lowering the fan speed, the only thing that bothers me is the customer says the unit used to kick a.....
-
04-21-2005, 09:19 PM
Thread: Crazy pressures/temperatures
by muchofreeo- Replies
- 19
- Views
- 1,317
Water temp is good, unit has a water regulating...
Water temp is good, unit has a water regulating valve. I'm thinking restriction as the suction goes into the compressor. Thinking about adding a couple of piercing valves to check pressures in...
-
04-21-2005, 09:04 PM
Thread: Crazy pressures/temperatures
by muchofreeo- Replies
- 19
- Views
- 1,317
Water flow is good, strainer is clean. Entering...
Water flow is good, strainer is clean. Entering air was 79 degrees, supply air was about 69 degrees. Direct drive fan motor running high speed, customer says unit used to run very good. This is a...
-
04-21-2005, 08:52 PM
Thread: Crazy pressures/temperatures
by muchofreeo- Replies
- 19
- Views
- 1,317
Was working on a 1/2 ton florida heat pump that...
Was working on a 1/2 ton florida heat pump that was only putting out 10 degree delta (evap) in cooling. Suction 80-85psig, Discharge 200-225psig.
This is a water source unit, another technician... -
03-28-2005, 06:49 PM
Thread: Motivation, incentives
by muchofreeo- Replies
- 32
- Views
- 1,510
Thank you R12 for your reply. My recent reply in...
Thank you R12 for your reply. My recent reply in this post was targeted to FAT EDDY. I had the audacity to question him in another post. His ego is probably bigger than his waist line. I really do...