Search:

Type: Posts; User: joeoilman

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. http://www.icmcontrols.com sc-3801 for your 2...

    http://www.icmcontrols.com sc-3801 for your 2 stage best thermostats out there today !!!!!
  2. Replies
    39
    Views
    3,161

    take a look at http://www.goodmanmfg.com & see...

    take a look at http://www.goodmanmfg.com & see what they have in print about warranteeing unit purchased over the internet.
  3. Replies
    14
    Views
    1,004

    i know a guy that says the dish on top of...

    i know a guy that says the dish on top of wally-world is the cause of all the bad in this country. home depot is backing them up too.
  4. Replies
    8
    Views
    1,425

    gas pressure could be a problem. valves are...

    gas pressure could be a problem. valves are designed to close with too much pressure. be safe,CALL A MILLER TECH!!!!!
  5. Replies
    29
    Views
    2,949

    nothing wrong with a beckett nx. very nice burner...

    nothing wrong with a beckett nx. very nice burner as a matter of fact. once you get used to them you'll like them.
  6. Replies
    21
    Views
    2,130

    been selling them 15 yrs & no problems yet....

    been selling them 15 yrs & no problems yet. although, i do size & install them properly. does make a difference.
  7. Replies
    21
    Views
    2,130

    10 gauge heat exchanger on the centennial. 14...

    10 gauge heat exchanger on the centennial. 14 gauge radiator. no heat exchanger problems with the cenntenial. you're thinking tempomatic. can't see the big deal over a copper spraypainted radiator....
  8. Replies
    21
    Views
    2,130

    go with a williamson centennial. 10 gauge heat...

    go with a williamson centennial. 10 gauge heat exchanger,beckett burner. thermopride,13 gauge heat exchanger,italian burner tough to get parts for.
  9. Replies
    26
    Views
    2,038

    nordyne has a 40,000 90% ...

    nordyne has a 40,000 90% http://www.nordyne.com
  10. Replies
    21
    Views
    1,841

    why do you want to lose all those btu's by...

    why do you want to lose all those btu's by switching to ng? it gonna cost you almost 30% more on ng. at least you're not on lp.
  11. Replies
    22
    Views
    2,400

    yellow markers ?

    yellow markers ?
  12. Replies
    7
    Views
    878

    maybe nordyne tech service can help. have model &...

    maybe nordyne tech service can help. have model & ser # when you call. 1-800-422-4328 & press 2
  13. Replies
    22
    Views
    2,400

    i just put in one of those 93% "army furnaces" 2...

    i just put in one of those 93% "army furnaces" 2 weeks ago. only thing i wasn't too crazy about was the condensate drain/trap setup. woulda liked a j trap better. runs real nice though. i think i...
  14. Replies
    6
    Views
    1,283

    where are you? how old is your furnace? your...

    where are you? how old is your furnace? your model# is
    cmf 80 po serial # ? when was the last time it was OPENED UP & cleaned ?
  15. Replies
    16
    Views
    1,026

    too bad buford pusser's not around to fix that...

    too bad buford pusser's not around to fix that kimd of stuff.
  16. Replies
    19
    Views
    9,111

    they run good with a beckett nx too

    they run good with a beckett nx too
  17. http://www.icmcontrols.com good stuff.

    http://www.icmcontrols.com
    good stuff.
  18. Replies
    11
    Views
    2,032

    is your condensate drain working properly? i had...

    is your condensate drain working properly? i had an m2 once that was popping & going off on vent safety & it was because the drain line was kinked & water was boiling in the hx.
  19. Replies
    11
    Views
    2,032

    there's a kit you can get so you can gut a roof...

    there's a kit you can get so you can gut a roof jack & go straight up through the roof. eliminates the bends. may work for you. don't have the part #. call tech service & ask for tom s.,he'll get it...
  20. Replies
    11
    Views
    2,032

    maybe it's because of turbulence or something....

    maybe it's because of turbulence or something. long radius elbows? static pressure test will tell. you don't have insulation or anything in the inducer or heat exchanger do you? i had one where the...
  21. Replies
    11
    Views
    2,032

    also,your intake is not sucking in exhaust air is...

    also,your intake is not sucking in exhaust air is it?
  22. Replies
    11
    Views
    2,032

    i had a vent safety switch tripping on an m3. it...

    i had a vent safety switch tripping on an m3. it was a draft in the wall behind the thermostat.(marriage wall)caused the furnace to short cycle. sounds like you need to do a static pressure test....
  23. Replies
    37
    Views
    2,008

    maybe you'll get lucky, & some cold dreary night...

    maybe you'll get lucky, & some cold dreary night you'll get to work on that cop's furnace & show him what a beating HIS wallet can take.
  24. Replies
    12
    Views
    1,660

    you could always use an electric furnace with a...

    you could always use an electric furnace with a split system ac. try an e3eb furnace from nordyne. ac ready & all. nice furnace! available in all their brands. http://www.nordyne.com
  25. Replies
    28
    Views
    1,572

    don't forget george " the animal" steele, or...

    don't forget george " the animal" steele, or ivan putski
Results 1 to 25 of 126
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event