    Would you explain the reheating comment you made...

    Would you explain the reheating comment you made medic? Are we just talking duct heat gain?
  3. Replies
    32
    Views
    1,016

    Everything you describe says air flow there must...

    Everything you describe says air flow there must be something you aren't seeing restricting air because if you had low static on high fan speed you would be 450-475/ton
  4. Replies
    32
    Views
    1,016

    It would have to be oversized duct with very low...

    It would have to be oversized duct with very low velocity to have .12 total static. I've never seen one.
  5. Replies
    32
    Views
    1,016

    No way your static is that low. But that...

    No way your static is that low. But that aside....how do you normally resolve low SH?
  6. Replies
    60
    Views
    4,391

    Could you elaborate on what you know to be true...

    Could you elaborate on what you know to be true on both of those?

    Does the BYpass factor alarm you because it's almost 1/2?
  7. Replies
    60
    Views
    4,391

    Wow I am impressed Brent! I just did my own...

    Wow I am impressed Brent! I just did my own comparison on one of my new installs (without the probes) and was within 50cfm of the blower chart as well. I am definately impressed.
  8. Replies
    3
    Views
    268

    If you add a filter it must be maintained. All...

    If you add a filter it must be maintained. All too often it is added and then not replaced regularly enough.
  9. Replies
    920
    Views
    66,131

    @jim - the app does then take outdoor temp into...

    @jim - the app does then take outdoor temp into account when calculating cfm? I ask because I wasn't entering that data lately. It seemed like all it needed was air across and tonnage.
  10. Check suction superheat leaving evap simultaneous...

    Check suction superheat leaving evap simultaneous too I guess!
  11. Replies
    35
    Views
    1,323

    I think You may be right but he wasn't testing...

    I think You may be right but he wasn't testing LRA there....guess my memory has failed me
  12. Replies
    35
    Views
    1,323

    I hate when that happens

    I hate when that happens
  13. Replies
    35
    Views
    1,323

    I thought there were guys with oscilloscopes who...

    I thought there were guys with oscilloscopes who found peak LRA was less with a start kit
  14. Replies
    920
    Views
    66,131

    Thank you Jim

    Thank you Jim
  15. Replies
    920
    Views
    66,131

    Thanks Brent I will love to see those compared to...

    Thanks Brent I will love to see those compared to your other airflow tools.

    I am impressed you get accurate readings at those kinds of velocities on the 25ton. What fpm was it?
  16. Replies
    920
    Views
    66,131

    Thanks for the reply medic. So you are...

    Thanks for the reply medic. So you are comfortable with nameplate tonnage to get within the 10%? Just so I'm clear you would reference the expanded data for conditions and use total btu/hr number for...
  17. Replies
    920
    Views
    66,131

    My question to Jim was air flow numbers are...

    My question to Jim was air flow numbers are drastically different with each nominal ton and same air side measurements (as it should) how does one trust this program?
  18. Replies
    920
    Views
    66,131

    Does the air mix better closer with an air...

    Does the air mix better closer with an air handler ?

    Also with all different sort of match ups as far as smaller pumps with bigger coils and more powerful fans vs older systems..how does this...
  19. Replies
    57
    Views
    7,142

    Lol! I don't think anyone caught this!

    Lol! I don't think anyone caught this!
  20. Replies
    920
    Views
    66,131

    I would like to discuss the estimated cfm...

    I would like to discuss the estimated cfm measurement some more. I'm still trying to figure out how it can know based on air side temp measurement, while playing with the app I see that nominal...
  21. Replies
    11
    Views
    528

    I like us motors formerly Emerson. Seem to do...

    I like us motors formerly Emerson. Seem to do well for me. If they are burning up for you they are not on correct application ....IMHO.Don't get the rescue ...get the 5458. I also will try and not...
  22. Replies
    10
    Views
    636

    I can see it now.....what did you do to get in...

    I can see it now.....what did you do to get in here?

    I put the wrong kind of flex duct laying on the ground! Oh boy that's a federal offense!
  23. Replies
    11
    Views
    528

    Sounds like you have experience the correct...

    Sounds like you have experience the correct problems...there are lots of better motors to use but it is more time consuming to get the right one.
  24. Replies
    10
    Views
    636

    I've never heard of getting police involved??

    I've never heard of getting police involved??
  25. That must have been before I was a member.?? I...

    That must have been before I was a member.?? I wonder if hvac5656/uncle/whoever else really bought tools like they were candy or not..??
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event