Search:

Type: Posts; User: ControlY0urMind

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. I remember my first beer.....

    I remember my first beer.....
  2. Replies
    10
    Views
    744

    Just to give you the rundown.... Most of the...

    Just to give you the rundown....

    Most of the 3rd party products that I have come across that do all the fancy graphs and gauges and all of the other eyecandy, use Flash. Flash was good at one...
  3. Replies
    4
    Views
    346

    That was in 3.8. Okay, try this...Select Text...

    That was in 3.8.

    Okay, try this...Select Text File Editor and once it's dropped onto the .px, grab a label from the palette (kitPx) or right click and create a label..........stretch it across the...
  4. Replies
    4
    Views
    346

    Easy.... Create a text file under the"Files"...

    Easy....

    Create a text file under the"Files" tree and add in your info. Simply drag and drop it on a .px and in the make widget wizard, add it as "Workbench View" then "Text File Viewer". Save the...
  5. Replies
    26
    Views
    1,068

    [QUOTE=Scott Kline;17971281]Sounds like the voice...

    [QUOTE=Scott Kline;17971281]Sounds like the voice of experience?

    We all start some where.....Who hasn't made toast out of a DDC device? :rolleyes:
  6. Replies
    53
    Views
    2,881

    Yes.....Just take tape and cover up the Tridium...

    Yes.....Just take tape and cover up the Tridium and write whatever you want on it.....

    Seriously though, I'm pretty certain it can be done. Should just be a matter of transferring some files and...
  7. Replies
    26
    Views
    1,068

    Just feed 110v to a BACnet/Lon controller.... ...

    Just feed 110v to a BACnet/Lon controller....

    The smoke alone will rid the bugs.
  8. Replies
    6
    Views
    492

    Everyone gets that error, if I'm not mistaken. I...

    Everyone gets that error, if I'm not mistaken. I know I do. It has something to do with the host.
  9. That's a vacuum tube from a guitar...

    That's a vacuum tube from a guitar amplifier........
  10. Replies
    7
    Views
    798

    Glad I could help. It's very easy to over think...

    Glad I could help. It's very easy to over think things like that.
  11. Replies
    7
    Views
    798

    I guess I'm confused.... You can still use a...

    I guess I'm confused....

    You can still use a SetPointFieldEditor widget on a px and set the ord to /OptStartStop/earliestStartTime or /OptStartStop/earliestStopTime and add a "Save" button on the...
  12. Replies
    7
    Views
    798

    What slot are you trying to command? Are you...

    What slot are you trying to command? Are you trying to write to "Next Event Time"? If so, just use a "SetpointFieldEditor" from kitPx and set the ord to the NextEventTime of the OSS block. Also keep...
  13. Replies
    17
    Views
    1,124

    or......just use windows tablets. The prices are...

    or......just use windows tablets. The prices are so low now, if you have a controls platform that you can hook a cheap wifi router into and access the system with a web browser, you can't ask for...
  14. Replies
    10
    Views
    779

    I couldn't imagine losing what you've lost.... ...

    I couldn't imagine losing what you've lost....

    Do what it takes, to get you through the day and just know that there's a guy out there praying for you.

    God bless.
  15. Replies
    8
    Views
    698

    I can't teach you hands on, but I can answer any...

    I can't teach you hands on, but I can answer any questions you have. My email is in my profile.....your more than welcome to email me any time you want to get schooled on something Tridium.
  16. The FX20 needs to be updated with the latest Java...

    The FX20 needs to be updated with the latest Java patch files in which you will need access to the Facility Explorer tool and access to a JCI vendor to get the update files.

    As a work around, you...
  17. Replies
    8
    Views
    436

    You need a program that will allow you to mount...

    You need a program that will allow you to mount the .ISO. PowerISO is what I use....

    An ISO is indeed an exact copy of a disc, but it has to be "mounted" in order to be used. PowerISO and programs...
  18. Replies
    4
    Views
    526

    That's the catch. Mobile graphics really aren't...

    That's the catch. Mobile graphics really aren't graphics with the current Niagara build. I think they are going to add more functionality at some point, but for now, you don't have much to play with.
  19. Replies
    1
    Views
    293

    DED, yep. If shell mode is gone, then go ahead...

    DED, yep. If shell mode is gone, then go ahead and start diggin a grave.
  20. Replies
    8
    Views
    701

    Thanks for the replies guys. We're needing...

    Thanks for the replies guys.



    We're needing something that can be moved from site to site and can gather information and relay it back to us. I understand that a transit time flow meter won't...
  21. BuildingLogix = Tridium AX The same as...

    BuildingLogix = Tridium AX

    The same as everyone else has, just with their logo.
  22. Replies
    8
    Views
    701

    I have. We're shooting for something mobile and...

    I have. We're shooting for something mobile and from what I could tell, the Onicon may be a bit too big. Ideally, I wish I could find a meter that would send out a 4-20 mA signal and not have a huge...
  23. Replies
    8
    Views
    701

    Non Invasive Flow Meters.

    Any of you guys ever had to install a non invasive/transit time flow meter?

    I'm trying to find one that will work with a pipe size of up to 4". I've called about a few and gotten the "We'll call...
  24. Replies
    15
    Views
    1,031

    I wish it were that easy. Upon a drop in...

    I wish it were that easy. Upon a drop in barometric pressure (a drop, indicates inclement weather is coming), I have to initiate a sequence that will pump down a rain collection tank. So I have to...
  25. Replies
    15
    Views
    1,031

    AX programming advice...

    I've got to program a sequence that will initiate on a detection of a rain event. Instead of just basing the sequence simply off of precipitation chances from the Weather Service, I have to use...
  26. Replies
    6
    Views
    720

    Unfortunately, yes you'll need it. Get me some...

    Unfortunately, yes you'll need it. Get me some contact info, and I can shoot it your way if you'd like.
  27. Replies
    6
    Views
    720

    I can honestly say you're the first person I've...

    I can honestly say you're the first person I've ever heard say that. :LOL:
  28. Replies
    6
    Views
    720

    Did you install the Honeywell AxWizard .jar? If...

    Did you install the Honeywell AxWizard .jar? If its showing up as a dynamic device, then your modules aren't jiving. It should come in as Xl15C, then after adding, invoke a "Learn" on the device to...
  29. Replies
    5
    Views
    484

    Nothing special. Just discover, add, then pick...

    Nothing special. Just discover, add, then pick out the points you want, just like any other device.
  30. Replies
    6
    Views
    527

    Are these tied into an NAE or something similar?...

    Are these tied into an NAE or something similar? Ive seen JCI jerry-rig alot of stuff with logic at the front end level. For example, Ive seen them write interlock logic for OA Dampers, totally...
  31. Replies
    5
    Views
    473

    You can also add links in the Px Editor,...

    You can also add links in the Px Editor, underneath the pxproperties dropdown.

    Add one called Font, set the type to "gx" and "font". When you add points from the make widget wizard, you can simply...
  32. Yes, you can connect with an FTP client via...

    Yes, you can connect with an FTP client via serial and extract the files.

    Use something like Filezilla and setup your connection. Put in your platform username and password and port 21 is the...
  33. Replies
    7
    Views
    532

    Let me do some playing around. I think using the...

    Let me do some playing around. I think using the "animate" bindings in your Px can help achieve what your going for.
  34. I feel your pain.... I just counted 14 on my...

    I feel your pain....

    I just counted 14 on my desktop. There's a program out there that you can install and it will automatically call the correct plat.exe to run when you open any wb.exe, so it...
  35. Ehh, I wouldn't recommend mixing modules,...

    Ehh, I wouldn't recommend mixing modules, although I've used kitpxGraphics in 3.6 builds. I used to have a bad habit of connecting to a JACE and just importing any module's from the JACE that were...
  36. Replies
    7
    Views
    532

    *Create an empty PX file. *Drop a tabbed pane...

    *Create an empty PX file.

    *Drop a tabbed pane from baja ui.

    *Drag a schedule onto the PX and select workbench view>scheduler.

    *Drag another schedule on top of it, and a new tab will be...
  37. Replies
    6
    Views
    472

    In your browser, type in xxx.xxx.xxx.xxx/login ...

    In your browser, type in xxx.xxx.xxx.xxx/login

    The x's represent the ip address of the JACE.

    Is this a new JACE or an existing one? If it's new and you haven't set up the station, then you wont...
  38. Replies
    6
    Views
    472

    No. Are you having problems?

    No.

    Are you having problems?
  39. Replies
    6
    Views
    780

    Yeah, you'll have to get the .xif... I used...

    Yeah, you'll have to get the .xif...

    I used NodeUtil to get the .xif then brought it in to AX.
  40. Dude, I had a fit at first. I logged about 40-60...

    Dude, I had a fit at first. I logged about 40-60 hours trying to figure out the process. I just finished my first project using them. About 400 controllers and bunches of JACEs and not one single...
  41. Learn how to utilize Export Tags. You'll be...

    Learn how to utilize Export Tags.

    You'll be thanking me, I promise. It will cut your engineering time sevenfold....
  42. Replies
    2
    Views
    398

    We need alittle more information..... Is this...

    We need alittle more information.....

    Is this a station running on your PC or is it a JACE your connected to?

    If its a station running locally, just find in your Niagara directory under...
  43. Sounds like port 80 may be blocked, in regards to...

    Sounds like port 80 may be blocked, in regards to the Niagara based instances. I can't speak for Trane or Alerton. The web service utilizes port 80 by default, so if you try to connect via web...
  44. Replies
    3
    Views
    403

    The category service is built in. You basically...

    The category service is built in. You basically set up different categories and then apply those permissions to different users.

    Lets say if you have an air handler graphic on a system. The...
  45. Replies
    11
    Views
    1,247

    Your security risk is what you make it. Almost...

    Your security risk is what you make it. Almost every customer I deal with has measures in place that would make it EXTREMELY hard for hackers to infiltrate. If you expose a JACE to the outside world,...
  46. Replies
    20
    Views
    4,160

    Well put. We have a job with a bunch of the...

    Well put.

    We have a job with a bunch of the UC10's that we installed and as soon as the warranty runs out, we're taking them out and replacing them with Distech. Nothing but timeout's and only 30...
  47. When using export tags, you can't edit a graphic...

    When using export tags, you can't edit a graphic from both sides.....When the PxTag gets sent up to the server, it's properties are frozen and it can only be edited in the subordinate JACE from which...
  48. That's gonna be a tough one. It's possible...

    That's gonna be a tough one. It's possible though. I know that you can parse a modbus registry and automatically create points and it's the same process with an excel spreadsheet and all.
  49. Replies
    1
    Views
    318

    I've done this before but will have to dig up...

    I've done this before but will have to dig up what I did. It's been a while.
  50. Replies
    14
    Views
    2,103

    You create the station locally, then sens it to...

    You create the station locally, then sens it to the JACE.
Results 1 to 50 of 423