Search:

Type: Posts; User: anthonyac1

Page 1 of 14 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    13
    Views
    853

    I spoke to trutechtools they told me the...

    I spoke to trutechtools they told me the accuracy/ sensor is the exact same. It's basically the battery use feature or 115v power only feature from the original h10. Combined into one leak detector....
  2. Replies
    33
    Views
    1,251

    Not yet. I'm going to change the batteries for...

    Not yet. I'm going to change the batteries for the heck of it this morning even though it's not saying low battery. Then I will compare the readings with another meter at the same time.
  3. Replies
    13
    Views
    853

    I don't know the difference that's why I posted...

    I don't know the difference that's why I posted it. For everyone else to put there input. Also it just came out I thought it was pretty interesting. I'm going to call trutechtools Monday to ask about...
  4. Replies
    33
    Views
    1,251

    Correct. That's why the clamp meter usually has 3...

    Correct. That's why the clamp meter usually has 3 lines and the wire should line up with the 3 marks. Basically the wire will be sitting in the center of the clamp,not touching the sides
  5. Replies
    33
    Views
    1,251

    I don't blame you. I would also change the motor...

    I don't blame you. I would also change the motor if it's over amping also because if it goes out in 2-3 days the customer is going to say well you were just here, why didn't you see that. mr....
  6. Replies
    33
    Views
    1,251

    I understand what ur saying. But technically over...

    I understand what ur saying. But technically over amping is over amping. I should not have to guess like hmmm well it's over but close so it will be ok. I never seen this before that's why I don't...
  7. Replies
    33
    Views
    1,251

    I also have the uei dl389 I had that meter for...

    I also have the uei dl389 I had that meter for the past 4 years. I had the same model but I get a new one like every 1.5 years. Because I either forget it at a job, or it got wet on the roof and had...
  8. Replies
    33
    Views
    1,251

    Maybe it's my meter, next time I run into this...

    Maybe it's my meter, next time I run into this I'm going to try my other meter to compare
  9. Replies
    33
    Views
    1,251

    I checked on both the motors nameplate and units...

    I checked on both the motors nameplate and units nameplate. It over amps according to the motors nameplate. I even showed the sales manager of the job. He used to be a tech. I said well being that's...
  10. Replies
    13
    Views
    853

    I also have a d tek and it's great. But on really...

    I also have a d tek and it's great. But on really small r410a leaks are harder to pick up compared to a r22 leaker. Sometimes with my dtek as soon as I put it in the condenser it starts going off....
  11. Replies
    13
    Views
    853

    Supposedly it has the best of both worlds between...

    Supposedly it has the best of both worlds between the h10g and the h10pm. I only worked with the h10 provided by the company I work for. But I'm looking to buy my own so I noticed the h10 pro I heard...
  12. Replies
    33
    Views
    1,251

    If I remembered correctly on this carrier the...

    If I remembered correctly on this carrier the name tag said 208/240 my actual voltage was 240. The Rheems were at a commercial condo building the actual voltage was around 200-208 volts I don't...
  13. Replies
    13
    Views
    853

    H10 pro leak detector

    The h10 pro leak detector us the new model leak detector just came out this past October. Trutechtools has it for sale. Supposedly they are going to discontinue the h10 and the h10 pm at the end of...
  14. Replies
    33
    Views
    1,251

    New cond. fan over amping

    Has anyone noticed on brand new condensers the condenser fan motors over amp. I did a start up on several Rheems and the fan motor for example was rated for 1.2 amps as per nameplate on the motor...
  15. Replies
    0
    Views
    215

    Perlick beer cooler t-stat

    For a 2door reach in beer cooler m# bs60 from the top of my head my notepad is at my desk n now I'm on the couch :) anyways the thermostat is part suction line temp sensing and part air temp sensing...
  16. Replies
    6
    Views
    475

    Condenser air filter

    I've always heard good about the air filters in front of the condenser air filters, I seen one today it was made from that blue and white filter media. But it was fillet/cut thin so it seemed to not...
  17. Replies
    10
    Views
    457

    Well that's the question all the home owners have...

    Well that's the question all the home owners have that's why they are given an arrow . Also they don't know about the direction of the airflow. Hell 9 out of 10 swear the fan outside is the fan that...
  18. Replies
    5
    Views
    291

    The rotation is correct. The condenser is...

    The rotation is correct. The condenser is deteriorated the fins are brittle. It's 16 years old. This unit sprung 2 leaks in the condenser, also the evap coil is really dirty I told her it's best to...
  19. Replies
    10
    Views
    457

    filter direction

    why is the filter directional arrow going opposite of the filter writing. Basically most homeowners slide the filter in so you can read the writing right side up. but if you follow the arrow the...
  20. Replies
    5
    Views
    291

    rheem condenser fan motor

    rheem condenser M#RAMA-030JAZ
    S#6088 M2398 08557

    I see on the condensers nameplate calls for a 1/8 hp but not sure on the rpms? Does anyone know the Rpm motor this unit calls for??? ...
  21. Replies
    5
    Views
    300

    Well I guess thermal fin can actually be a lot of...

    Well I guess thermal fin can actually be a lot of things. Basically it's fins that absorb or reject heat, fins on a coil, or fins on a transformer to dissipate heat. So yes it can be a radiant...
  22. Replies
    21
    Views
    1,227

    R-22 is good with Poe oil your right. That's...

    R-22 is good with Poe oil your right. That's compatible, But it depends what oil was in the system before? maybe mineral oil just as an example. I was taught that you don't want to mix oils. Also...
  23. Replies
    3
    Views
    358

    Thanks for the replies and info. I knew about the...

    Thanks for the replies and info. I knew about the pulley diameters affecting the speed but I wasn't sure if the belt length had any affect. That clears up my question now good to know
  24. Replies
    3
    Views
    358

    Change in belt size

    Now the question is it the longer the belt the slower the the blower wheel will turn in relation ship to the drive motors rpms. I'm picturing in my head the closer the drive pulley is to the driven...
  25. Replies
    5
    Views
    300

    Thermal fin???

    What is the proper name for that thin aluminum tubing usually used for the dryer exhaust pipe. I was taught that it's called thermal fin. What's the proper name for that type of pipe/tubing?
  26. Replies
    46
    Views
    5,417

    Thank you for replying back to me. I did receive...

    Thank you for replying back to me. I did receive the scale back from you, I used it today and worked flawlessly! It looks like a new scale either way I'm happy with the end result thanks again. It...
  27. Replies
    21
    Views
    1,227

    Most likely he is going to have you put in that...

    Most likely he is going to have you put in that r404a compressor,change filter dryer,pull vacuum and just fill it with r22. It may run but might not run properly or long term, r22 can run happy with...
  28. Replies
    46
    Views
    5,417

    I reread my post about the scale letting me down....

    I reread my post about the scale letting me down. When I mentioned I threw away the paper with the info to ship it back I should have made it more clear that part was an accident I wrote it down on a...
  29. Replies
    46
    Views
    5,417

    It always worked pretty good when I needed it. I...

    It always worked pretty good when I needed it. I was just disappointed that it had a failure. But if you have that many in the field of course there may be an issue with a few here and there. Things...
  30. Replies
    46
    Views
    5,417

    Yoooooiooooooo!!! Well I'm back here right shy of...

    Yoooooiooooooo!!! Well I'm back here right shy of a year and a half. I've been using the scale from acuutools. Well ever time I'm in the back of my van once in a while I would hear a beep beep. I...
  31. Replies
    7
    Views
    578

    Thanks for the info.

    Thanks for the info.
  32. Replies
    7
    Views
    578

    Thanks for the detailed info. Your right about...

    Thanks for the detailed info. Your right about sizing for the future thinking it's going to get damaged or so. I kind of stated wrong my fault. I was dozing off as I was making that post. I guess...
  33. Replies
    7
    Views
    578

    Upsize condensing unit for reach ins

    These reach ins (freezer/coolers) once they get older start to run high head pressure yes they can be cleaned with degreaser/coil cleaner but over the years the condenser fins get loose from the...
  34. Replies
    21
    Views
    1,343

    Yeah those hours I like but now I'm not motivated...

    Yeah those hours I like but now I'm not motivated especially since I know I'm leaving
  35. Replies
    21
    Views
    1,343

    Hahahaha. Alot of people who I've heard gave a 2...

    Hahahaha. Alot of people who I've heard gave a 2 weeks notice they got terminated right there. I understand why in a way because you don't want an employee out on your job sites who is planning on...
  36. Replies
    21
    Views
    1,343

    Good excuse to leave an employer

    Here's the story I worked non union about 6 years, then I got into the union as a white ticket I swore in about 2 years ago. Well after 1 year I said naw I'm leaving I told my supervisor that I want...
  37. Replies
    14
    Views
    905

    Sounds pretty good. I've never used co2 before is...

    Sounds pretty good. I've never used co2 before is it cheaper? Are the metal bottles heavier than the nitro bottles? Can you refill them at your local hvac supplier? Is it dry like to also use it to...
  38. Replies
    8
    Views
    497

    I like the idea of using a larger piece of pipe...

    I like the idea of using a larger piece of pipe because you can cut in slightly large than the repaired section then slide it all the way towards one side then slide it onto the other side kind of...
  39. Replies
    8
    Views
    497

    It's a thick coil it's on the top side (supply...

    It's a thick coil it's on the top side (supply air side) so as far as the condensation draining off properly I think it should be ok. About 3-4 passes but I wouldn't be eliminating them I would...
  40. Replies
    8
    Views
    497

    I don't know how to attach a picture to my post...

    I don't know how to attach a picture to my post of the evap coil smashed
  41. Replies
    8
    Views
    497

    Evap coil repair

    This evap coil someone tried to repair on a York 15 ton a/h. They crimped the tubing supposedly the guy thought about eliminating these leaking circuits. Well our company was recommended and the...
  42. Replies
    14
    Views
    905

    Is it loud when it's filling up the tank? Also...

    Is it loud when it's filling up the tank? Also does it have to fill up a lot for example it pretty much runs the whole time while working . I've seen the little red pancake I know the one your...
  43. Replies
    14
    Views
    905

    Air compressor to blow out coils

    During pm's or even service calls to blow out condenser coils on the reach in coolers/freezers. Also hit the drain lines nitrogen is good but you can go through a bottle pretty fast during a pm. Does...
  44. Replies
    3
    Views
    528

    Duct design software

    I was told about this software called elite. It's a software that designs duct work and calculates the total duct sizes after you plug in some numbers. Has anyone worked with this program or has...
  45. Replies
    8
    Views
    351

    I appreciate the knowledge. Ima show up there...

    I appreciate the knowledge. Ima show up there early in the morning to put in the motor. I didn't want to wait for Rheem to open to find out. Just curious how did you find the info. Maybe from...
  46. Replies
    8
    Views
    351

    rheem condenser fan specs

    i went to a rheem condensing unit today. The condenser fan had shorted windings. on the condensers name plate it states 1.2 rla 1/5hp in the unit was a rescue motor 1/6-1/3 hp. 1075 rpm but rated...
  47. Replies
    4
    Views
    431

    Here in sunny south florida in the winters it...

    Here in sunny south florida in the winters it doesn't get cold. Maybe 0ne night it will hit 35-40 degrees f. But anyways with the condensers running it won't get to cold up there. But mainly our...
  48. Replies
    4
    Views
    431

    ambient temp. comditions

    I was at a school the other day and there were 4 walk in coolers with there condensers up in the ceiling. it was 114 degrees up there. There are about 5 ceiling tiles that are missing in the drop...
  49. Replies
    2
    Views
    321

    tecumseh start components kit

    just like danfoss makes a kit with a few body styles and different cartridges they put a kit together to keep on the truck. well for Tecumseh I thought I read on here that they have a similar kit...
  50. Replies
    15
    Views
    804

    The txv will respond to the low suction line temp...

    The txv will respond to the low suction line temp could be due to low airflow causing the valve to do its job and close down. I'm not arguing with what anyone is saying nor going against what has...
Results 1 to 50 of 672
Page 1 of 14 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event