02-20-2012, 07:32 PM
Thread: Reach-In-Refrigerator Preference
by taddsplace- Replies
- 6
- Views
- 1,550
Trues are good for the price. Traulsen, and...
Trues are good for the price. Traulsen, and Hobart are your higher end coolers.
-
02-20-2012, 06:58 PM
Thread: hobart
by taddsplace- Replies
- 2
- Views
- 541
Hobart been around for years and there equipment...
Hobart been around for years and there equipment last for years.
-
02-19-2012, 11:21 AM
- Replies
- 7
- Views
- 787
Crystal tip is out of business . But I have taken...
Crystal tip is out of business . But I have taken a Ice-O-Matic purge valve and made it work on a Crystal tip.
-
02-18-2012, 09:38 PM
Thread: Cornelius XAC530
by taddsplace- Replies
- 1
- Views
- 607
Sounds like the evap sensor off the circuit board...
Sounds like the evap sensor off the circuit board is bad. Ice builds on the evaporator and when it gets down to a certain temperature, ice should be fully formed on the evap and ready to drop. If the...
-
02-18-2012, 09:10 PM
Thread: looking for extra resources
by taddsplace- Replies
- 17
- Views
- 770
Here are some on line training web sites....
Here are some on line training web sites. www.hvacreducation.net www.nalcomfortinstitute.com www.ashrae.org
-
07-31-2011, 04:25 PM
- Replies
- 3
- Views
- 833
The 38CKC024340 is only for the outside unit. It...
The 38CKC024340 is only for the outside unit. It is a 2 ton 10 seer R22 outdoor condensing unit. That system will only have one evap coil. If it is an electric unit, the evap coil will be built...
-
07-31-2011, 01:30 PM
- Replies
- 7
- Views
- 1,623
Condenser fan motor should come on unless it is a...
Condenser fan motor should come on unless it is a variable speed motor, or it has a low ambient control on it. Variable speed condenser fan motors come usually on 18 seer and up condensing units. ...
-
07-31-2011, 01:00 PM
Thread: Help choosing a furnace
by taddsplace- Replies
- 8
- Views
- 425
I have worked for a Carrier dealer for 18 years...
I have worked for a Carrier dealer for 18 years and have worked on many Infinity units. The Infinity unit is a whole lot easier to trouble shoot and work on than a Performance Series. It holds logs...
-
07-31-2011, 12:28 PM
Thread: how long does it take?
by taddsplace- Replies
- 16
- Views
- 1,695
Most of the time it takes about 5 to 6 hours...
Most of the time it takes about 5 to 6 hours depending on how much clean up you have to do to the system. For example, it will take more time if you have a burnout with black oil or moisture in the...
-
05-19-2011, 09:10 PM
- Replies
- 26
- Views
- 5,729
If they are the right side you dont have to...
If they are the right side you dont have to change the lineset.
-
05-19-2011, 08:23 PM
Thread: RLD-H10 Leak Detector Repair
by taddsplace- Replies
- 7
- Views
- 1,054
Most of them have a sensor that senses the freon...
Most of them have a sensor that senses the freon and you can replace it. Those sensor go out after a while. Check out the manufacture website.
-
05-19-2011, 08:09 PM
Thread: Ice Machine Cleaners ?
by taddsplace- Replies
- 14
- Views
- 1,790
On cubers use nickel safe and on flakers use...
On cubers use nickel safe and on flakers use stronger cleaner.
-
05-19-2011, 07:47 PM
- Replies
- 2
- Views
- 919
It is a cheaper brand like Goodman. Trane,...
It is a cheaper brand like Goodman. Trane, Carrier, Lennox are your better brands.