  1. If the system has a txv the compressor needs a...

    If the system has a txv the compressor needs a start cap. if it doesn't have one it's going to tripp the breaker and possibly short the compressor again. The company should know this and most...
  2. Replies
    9
    Views
    1,163

    Thanks Dave. I was changing the names as you were...

    Thanks Dave. I was changing the names as you were writing your last reply. Thanks a ton.
  3. Replies
    9
    Views
    1,163

    ok thanks. I hope thats enough for the help I'm...

    ok thanks. I hope thats enough for the help I'm needing. I have the addys for the others, but they don't seem to want to come up right in the post at hvac talk
  4. Replies
    9
    Views
    1,163

    i hope this is right.

    http://www.imagewiz.net/usr/hvac1/unit/12292_MVC-003S[3].JPG

    [Edited by walter cole on 07-10-2005 at 12:25 PM]
  5. Replies
    9
    Views
    1,163

    Don't know if I did this right ?

    hope this thing is right now.thanks for any help.http://www.imagewiz.net/usr/hvac1/unit/12296_txv's].JPG
    http://www.imagewiz.net/usr/hvac1/unit/whatbrand.JPG[/url]...
  6. Replies
    16
    Views
    6,944

    It's not always the return's fault

    If you supply air plenum and duct system are too small. The pressure along with the humidity. This is not the case in most houses but it does happen. If you have mold in your supply plenum thats more...
  7. Replies
    16
    Views
    6,944

    Professional mambers

    Don't think the home owner came in here looking for a hard time. Thier just looking for some insight.
  8. Replies
    10
    Views
    3,246

    Lennox

    Lennox go with a Lennox for quiet operation.
  9. Replies
    56
    Views
    7,351

    Stuff the hole behind the stat??

    Did you block any holes that me be behind the stat. If you have any kind of draft or way that the heat can transfer down the wall to the stat it will read the wall temp befor it reads the room temp.
  10. Replies
    15
    Views
    9,308

    The pressure on the highsideshould be about 225...

    The pressure on the highsideshould be about 225 to 300. If the line temperature is close to the outside temp. your probaly overcharged. Look at the pressure chart or you gages and subtract the line...
  11. Replies
    16
    Views
    6,944

    How much cfm does a 14 and 16 inch pipe pull and how much cfm return air do you need

    The flexible duct will handle less then a lot of people seem to give them credit for. The 16 will handle about 1000cfm's at .02" of static pressure , depending on the length as Dan says. If you have...
  12. Replies
    31
    Views
    6,688

    if your system is oversized it will short cycle...

    if your system is oversized it will short cycle and not remove latent heat which is humidity. you have to run it colder to feel comfortable. positve pressure is a must.and what is a good filter?...
  13. Replies
    4
    Views
    2,943

    if the coil is clean how about the blower. and if...

    if the coil is clean how about the blower. and if it's clean then have the insulation inspected in the airhandler itself(unit in attic)the unit is running to cold it will produce conditions for mold...
  14. Replies
    5
    Views
    4,009

    yes it probaly is ozone and with the alpine or...

    yes it probaly is ozone and with the alpine or any electronic this will happen. ask the contractor if there is a setting for that filter high medium and low this may help if the odor is to great to...
  15. Replies
    24
    Views
    5,352

    Where in Florida?I'm here too. Sorry to hear you...

    Where in Florida?I'm here too. Sorry to hear you have a Rheem But they will work and last as long as there installed correctly and charged right.Rheem has reduced the size of thier equiptment so as...
  16. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    now that what i think the people that started...

    now that what i think the people that started this forum were looking for when they started it. encouragement!! i think this kind of project can teach of all a little something wheather it be...
  17. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    there is a chat room on here ya'll know?

    there is a chat room on here ya'll know?
  18. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    while the start caps do have higher ratings thet...

    while the start caps do have higher ratings thet will also have a potential relay and the kick start brand is the only i know to have the tru potentail relay.they usally black with two wires one go...
  19. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    naw it's an extra cap that works in conjunction...

    naw it's an extra cap that works in conjunction with your run cap to kick the compressor in the but to get it goin the good one drop out after abotu a milli second but all the spp series will stay in...
  20. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    yeah they are all run caps. when you use a TXV in...

    yeah they are all run caps. when you use a TXV in a system you need a hard start cap. the new TXV's do what the manufactorers call a hard shut off. with=ch from what they say puts a sort of back...
  21. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    sure will do. a start cap is an extra cap you put...

    sure will do. a start cap is an extra cap you put in conjunction wit the run cap to give the comprewssor a kick in the rear to get it hummin
  22. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    it's a start cap. the good ones have true...

    it's a start cap. the good ones have true potential relays on them and any of the spp series do not have true relays on them.i have had to many relays changed du to the spp series caps taking the run...
  23. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    pleae dont use an spp anything on that thing it...

    pleae dont use an spp anything on that thing it will blow up in ur face.
  24. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    like i said in my last post it's a nice little...

    like i said in my last post it's a nice little project and good luck with it whatever you use it for.Shophound had the real qusetions and go back to what i said as well. CFM'S relate to all the...
  25. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    While this is a neat little prodject theres some...

    While this is a neat little prodject theres some things that will keep it from getting very far in it's life. Theres a lil thing called Cubic Feet per Minute that needs to be addressed on both the...
  26. Replies
    20
    Views
    3,174

    I didnt bother to read all the post before i...

    I didnt bother to read all the post before i answered so if this sounds silly so be it.By a colonial i think of a house on blocks or above ground with crawl space under? If that the case you may want...
  27. Thread: home built ac

    by SNOOKER
    Replies
    191
    Views
    18,100

    any system with a TXV needs a startcap and if you...

    any system with a TXV needs a startcap and if you get a good one like a TO-5. It will have the relay with it. have you checked your electrical connections to make sure thier tight and makeing a good...
  28. Replies
    15
    Views
    2,903

    The code here in south Florida is for sweating as...

    The code here in south Florida is for sweating as you know we don't get much cold weather down here.
  29. Replies
    15
    Views
    2,903

    Looks great.Just a question? where's the trap and...

    Looks great.Just a question? where's the trap and the armaflex at the unit? maybe the code is different where you are, but we have to insulate at least 6 ft.after a/h and the makers of the equptment...
  30. Replies
    2
    Views
    774

    Take the temp of the jug and use the...

    Take the temp of the jug and use the corrosponding pressure to find the number you require.Use the chart on your gages or the one you should have on your truck.I use you as a general term not you...
  31. Replies
    36
    Views
    33,868

    IT'S HARD TO STOP A TRANE.

    IT'S HARD TO STOP A TRANE.
  32. Replies
    87
    Views
    32,597

    Well Steve looks like you have plenty replies and...

    Well Steve looks like you have plenty replies and here is another. I couldn't have possibly suffered through anymore so i only read two pages it looks like the 40 % rules stands. That is that their...
  33. Replies
    34
    Views
    6,959

    First thing is to make sure your satic pressure...

    First thing is to make sure your satic pressure in your ducts are right both supply and especially return. Ofcorse this is assumeing that the systems are the right size for the load.7 5 ton units ?...
Results 1 to 33 of 34
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event