  1. Thread: Frustrated

    by crt
    Replies
    18
    Views
    1,972

    Clean Effect Inside

    This unit comes with it's own cabinet mounted external to the furnace cabinet. I am begining to wonder if you really got a clean effect unit? Is the cleaning section inside look like a honey cone?????
  2. Thread: Frustrated

    by crt
    Replies
    18
    Views
    1,972

    Trane Freeze Up

    Your problem is an undersized blower. The Clean Effects is a very high static machine and your blower can not deliver the air the system needs with that unit there. To prove this to yourself, remove...
  3. Replies
    28
    Views
    2,771

    10-2 (copper Conductors) with ground for 50' of...

    10-2 (copper Conductors) with ground for 50' of wire is just right. You should size the breaker for what the unit name plate calls for, but not larger than 30 Amps Maximum.
  4. Replies
    25
    Views
    2,389

    I am not sure that the Arzel System controller...

    I am not sure that the Arzel System controller can cycle first and second stage compressor operation or gas valve operation with the discharge air sensor. It sounds to me that the compressor is...
  5. Replies
    16
    Views
    2,637

    SEER 10,12,13,14,15,16 the failure rate is...

    SEER 10,12,13,14,15,16 the failure rate is usually higher on the lower SEER units because most of them have less protective devices. As for how much energy you will save will depend on your climate,...
  6. Replies
    5
    Views
    697

    Dof3 is correct. I would put filter material in...

    Dof3 is correct. I would put filter material in my return air grilles and change the filters in you system after the finish has dried. I would also run my blower/fan constantly during this prcess to...
  7. Replies
    14
    Views
    1,865

    Sounds like the installer used the directions for...

    Sounds like the installer used the directions for knee pads when connecting the refrigerant piping!!!!!!!!!
  8. Replies
    18
    Views
    1,582

    First of All: HomeDepot allows the contractor...

    First of All:

    HomeDepot allows the contractor to provide man power for the 10 SqFt of space in the building. For this the contractor has the right to sell you an air conditioner and furnace. Now...
  9. Replies
    7
    Views
    966

    Zoning

    Airworx is 200% correct in his statements. Now the question of does a variable speed blower come into effect on a zoning system? Only if you are installing the Infinity Carrier Zoning System. If you...
  10. Thread: Hot Upstairs

    by crt
    Replies
    47
    Views
    5,340

    While I am a great advocate of zoning systems and...

    While I am a great advocate of zoning systems and mostly agree with many of the same opinions of jramunni, I thought this forum is not for the promotion of ones manufacturing of products. This...
  11. Thread: Hot Upstairs

    by crt
    Replies
    47
    Views
    5,340

    Without installing a zoning system or a second...

    Without installing a zoning system or a second unit in the attic, which is also a zoning system, you are only treating the symptoms not the problem. The second floor will always be warmer than the...
  12. Replies
    76
    Views
    4,586

    Dash: I agree with your comments in regard to...

    Dash:

    I agree with your comments in regard to the industry being in its infancy "BG" but Goodman isn't the first cheap piece of equipment to come on the market. I remember the Janitrol name four...
  13. Replies
    76
    Views
    4,586

    Excuse Me: Chillbilly / Madeinusa / Steve Potvin...

    Excuse Me: Chillbilly / Madeinusa / Steve Potvin

    First you obviously do not understand the law. The consumer has every right to expect the installer to be competent. He is representing himself as...
  14. Replies
    22
    Views
    2,274

    The carrier infinity systems varies the blower...

    The carrier infinity systems varies the blower output and uses modulating dampers. This system has its advantages and disadvantages. It is a very expensive product and if you are dead set on a...
  15. Replies
    76
    Views
    4,586

    "The best way for a consumer to get an issue...

    "The best way for a consumer to get an issue resolved is to complain to a manufacturer’s rep, which is usually within the distributor. If that distributor happens to be a friend of a friend that sold...
  16. Replies
    22
    Views
    2,274

    Heetseeker: Arzel's modulating damper depends...

    Heetseeker:

    Arzel's modulating damper depends on a motor of some type, electric or pneumatic running open and closed based on discharge air static pressure, no different than everyone else. There...
  17. Replies
    76
    Views
    4,586

    Why is everyone avoiding the obvious!!!!! ...

    Why is everyone avoiding the obvious!!!!!

    First no place does subwoofer indicate this contractor was a friend.

    Second it is extremely obvious he has been had.

    Third no reflection on RoBoTeq...
  18. Replies
    76
    Views
    4,586

    The reason for calling two new contractors...

    The reason for calling two new contractors instead of the installing contractor is quite simple, he has no idea what he is doing. The suggestion of calling the distributor is even funnier. You are in...
  19. Replies
    22
    Views
    2,274

    First: Yes a zoning system will work on a...

    First: Yes a zoning system will work on a Variable Speed Blower, but it needs a barometric bypass damper not a modulating one. Modulating dampers operate to slow and will make the VS search...
  20. Replies
    76
    Views
    4,586

    For a two ton system you should have a minimum of...

    For a two ton system you should have a minimum of (1) 14" or (4) 9" returns. A 6" pipe maximum CFM is 100 CFM so you have (4) you have 400 CFM recommended capacity. You desparately need to talk to a...
  21. Thread: Goodman

    by crt
    Replies
    66
    Views
    11,026

    CRt will find out who you are...be careful...

    CRt will find out who you are...be careful
    __________________
    No heat No cool you need Action fast and Constantly


    I already know you live close enough to the Mistake on The Lake. The only...
  22. Thread: Goodman

    by crt
    Replies
    66
    Views
    11,026

    __________________ No heat No cool you need...

    __________________
    No heat No cool you need Action fast and constantly


    Definitely must be a Goodman
  23. Thread: Goodman

    by crt
    Replies
    66
    Views
    11,026

    __________________ No heat No cool you need...

    __________________
    No heat No cool you need Action fast


    Must be a Goodman Unit
  24. Thread: Goodman

    by crt
    Replies
    66
    Views
    11,026

    __________________ No heat No cool you need...

    __________________
    No heat No cool you need Action fast

    Looks like a Goodman Equipment Job!!!!!!!!!!!!!!!!!!!!!
  25. Thread: Goodman

    by crt
    Replies
    66
    Views
    11,026

    It is difficult to get into a war of brains with...

    It is difficult to get into a war of brains with unarmed people.