    Zone 1 works fine on its own, when I was there...

    Zone 1 works fine on its own, when I was there testing. No power drop that I saw. Did not duplicate error because of customer pushing me out the door @ 5.

    I will be heading back tomorrow.
  2. Replies
    2
    Views
    361

    honeywell zone controls

    I have a honeywell truezone and 1 add-a-zone panel for an office. They are using 6 zones. The customer complains about the lobby (zone 1) not staying a consistent temp. All zone set the same...
  3. Replies
    22
    Views
    1,196

    All heat strips are mounted above the evap...

    All heat strips are mounted above the evap coil...I don't think u will have any issues.
  4. Replies
    14
    Views
    1,051

    Where is the ignitor in relation to the burners?

    Where is the ignitor in relation to the burners?
  5. Replies
    14
    Views
    1,051

    Did you tey wideing the crossover or swapping...

    Did you tey wideing the crossover or swapping burners around? I take it you looked at the orifice. Try pulling the manifold off and see if there is debris?

    Did you get the burner to ignite...
  6. Replies
    24
    Views
    1,637

    I like to be a tech, make me feel good fixing...

    I like to be a tech, make me feel good fixing things. I don't push on sales just try to educate customer about better systems. At the company I work for we give the leads to a salesman and they go...
  7. Replies
    22
    Views
    1,196

    I worked an oil furnace with electric heat strips...

    I worked an oil furnace with electric heat strips and the customer had the electric heat strips mounted in the supply over the furnace. Where he lived the electric rate was cheaper than oil...had a...
  8. Replies
    10
    Views
    758

    Install a taco zone valve after the coil, the...

    Install a taco zone valve after the coil, the taco is orange not green power head. Then on the inlet of the coil install a gate valve and a sight glass flow meter, something that tells you gpm. ...
  9. Replies
    140
    Views
    8,899

    How many shut the pump off while it is in a...

    How many shut the pump off while it is in a vacuum? They say of you do you could seize the vains and need a new pump.
  10. Replies
    9
    Views
    694

    Don't forget to make sure a bleed resistor is on...

    Don't forget to make sure a bleed resistor is on the start cap.
  11. Replies
    9
    Views
    694

    Relay

    Relay
  12. Thread: Aspen 416

    by MontanaJon
    Replies
    10
    Views
    1,172

    I use 416 on all my r12 conversions at med temp. ...

    I use 416 on all my r12 conversions at med temp. Dont have to derate 20% of charge. Also look it in reach ins, do have afew larger systems (10+#'s) and they work just fine. 416a is not designed...
  13. Thread: gauges

    by MontanaJon
    Replies
    26
    Views
    2,055

    I have 4 sets of gauges and just ordered an...

    I have 4 sets of gauges and just ordered an ak-900, really curious if I will like them. Now one of mine are stubies for ice machines andreach-ins. And my old 3 port for checking oil...
  14. Thread: rant

    by MontanaJon
    Replies
    8
    Views
    660

    Omg...r u f*n serious....I was at the parts house...

    Omg...r u f*n serious....I was at the parts house and this guys aske me, "how the hell do u fix one of those Carrier pick-n-hold furnaces". I laughed and said, "you find a crack in the heqt...
  15. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    386

    Lol...so I was there at 10pm to 1230am and today...

    Lol...so I was there at 10pm to 1230am and today I walked around and found another cooler with freezer inside...hmmm..only one low temp and med temp condensor outside. Cases ran together in...
  16. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    386

    Oh yea ran 40 yesterday.

    Oh yea ran 40 yesterday.
  17. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    386

    Beer cooler

    Customer called me friday night coolcooler above 50. Arrived on site unit cycling on hp switch. One condensor fan down. Replacedfan and ran system. Pumped down system and poping hp switch. ...
  18. Put in water cooled condensor...lol

    Put in water cooled condensor...lol
  19. The txv you installed is pressure limiting? ...

    The txv you installed is pressure limiting? Theory- not flowing enough refrigerant to remove load. Coil is flooding? and way superheated but still trickling along at 50 psig. New standard txv...
  20. Replies
    19
    Views
    1,091

    According to my 407c pt chart your vapor pressure...

    According to my 407c pt chart your vapor pressure temp should be 48 instead of 38. Either yor sh math is wrong or mistype for sp/temp.

    3 over ambient with 13 sc. That's got to be the best...
  21. It's hard to say if you are oversized on your...

    It's hard to say if you are oversized on your unit without doing a load calculation on your house. I would get the parts replaced while they are still under warranty because a heat pump would be...
  22. Replies
    9
    Views
    727

    BTW- when I said flush the lines I also mean the...

    BTW- when I said flush the lines I also mean the evap. You will probably use 2-4 cans of nitogren.
  23. Replies
    9
    Views
    727

    I am not sure how big the coil is for 410a but...

    I am not sure how big the coil is for 410a but the r22 coils I am thinking of are 5'x4' 2-3" thick. Is it a scroll for the 410a unit? I know in the 22 systems they were bristols and weighed 60-80#....
  24. Replies
    9
    Views
    727

    Well, with the compressor you Will want to change...

    Well, with the compressor you Will want to change the oil, possibly flush the lines and of course new filter. Is the coil seperate from first stage? I think they are if it V shaped. Not much there...
  25. Where do u live? How many square ft is the house?...

    Where do u live? How many square ft is the house?

    Also I would contact carrier directly, I do believe the warranty for any equipment used on a house has more than 1-3 yr warranty.
Results 1 to 25 of 73
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event