05-01-2010, 07:54 PM
Thread: high evaporator static
by bubbahotemp- Replies
- 13
- Views
- 864
After looking at the Goodman site I found the...
After looking at the Goodman site I found the info, don't know why I missed it, (I'm smacking my self in the forehead right now, duh!) My original post I said .50 which was a typo it is .38 on the...
-
05-01-2010, 06:13 PM
Thread: high evaporator static
by bubbahotemp- Replies
- 13
- Views
- 864
A Goodman 3-ton/13 seer/Model#GSC130361 Goodman...
A Goodman 3-ton/13 seer/Model#GSC130361
Goodman Model furnace - GMV950905DX-92,000 Input
Unfortunatly Goodman does not have much data on there products, I see in the Johnstone catalog the model... -
05-01-2010, 05:46 PM
Thread: high evaporator static
by bubbahotemp- Replies
- 13
- Views
- 864
Could I have used a 4ton coil for a 3ton...
Could I have used a 4ton coil for a 3ton condensing unit, is there any pro and cons to this practice? Would that add more heat to the suction gas and raise compressor temps?
At .94 ESP, at that... -
05-01-2010, 01:26 PM
Thread: high evaporator static
by bubbahotemp- Replies
- 13
- Views
- 864
high evaporator static
Hello Gentleman,
I recently installed a Goodman 90,000btu output variable speed furnace with a 3-ton coil, my problem is when I took the total ESP between the coil of the furnace and between the... -
12-15-2008, 08:15 AM
Thread: Carrier Rooftop gas Pressure
by bubbahotemp- Replies
- 4
- Views
- 519
Oh by the way the heat exchanger had several...
Oh by the way the heat exchanger had several gaping holes in it, looked like swiss cheese probably what led up to it's failure. There was soot buildup on the outlet of the vent. Never ran into this...
-
12-13-2008, 10:09 AM
Thread: Carrier Rooftop gas Pressure
by bubbahotemp- Replies
- 4
- Views
- 519
Carrier Rooftop gas Pressure
Anybody run into this problem???
Spark ignition carrier rooftop
I put my digital manometer gauge on the outlet of the gas valve and I was reading 4.5" WC. I go and take the adjustment cap... -
07-07-2008, 12:09 PM
Thread: Increased life on compressor....?
by bubbahotemp- Replies
- 16
- Views
- 965
Compressor life
Thanks for replies, anyway thanks for the info on crankcase heater, I know most techs hate Goodman except home builders, but I got a good deal on it, I know shame on me, but it is a 14 seer. Other...
-
07-06-2008, 12:49 PM
Thread: Increased life on compressor....?
by bubbahotemp- Replies
- 16
- Views
- 965
Increased life on compressor....?
Been in the biz for 10+ years, I am installing a new R410A for my own house would putting a liquid solenoid on and letting it go into pumpdown mode when the thermostat satisfies would allow the...
-
07-01-2008, 03:50 PM
Thread: Bulging cappy
by bubbahotemp- Replies
- 5
- Views
- 418
Bulging cappy
Anyone know the reason why the capacitor bulges? I had to replace one on a rooftop recently.
Also can I use a 440v rated voltage rather than a 370v on a Capacitor? If the unit's voltage is... -
09-08-2007, 11:08 AM
Thread: A/c service myth questions plz hlp
by bubbahotemp- Replies
- 4
- Views
- 925
A/c service myth questions plz hlp
Hi everybody, new to this forum been a tech for 2 years
Just had some questions related to residential a/c :
1. Is it true on scoll compressors that you can't use hard start kits on them... -
03-08-2007, 05:44 PM
Thread: You guys ever think of this??
by bubbahotemp- Replies
- 19
- Views
- 1,190
Thanks for the replies, I was also thinking to...
Thanks for the replies, I was also thinking to preserve the copper tubing I can replace the dirt with sand, take a spool of soft 25' 3/8 copper. The ground " would not just heat up" it would...
-
03-07-2007, 07:33 PM
Thread: You guys ever think of this??
by bubbahotemp- Replies
- 19
- Views
- 1,190
You guys ever think of this??
I've been in a/c for 10 years, After all the efficiency buzz about SEER, I was thinking how to make an a/c more effiecient. Then I realized someone could take the liquid line at the outlet of the...
-
09-12-2006, 04:13 PM
Thread: Help with Walk-in Refer.
by bubbahotemp- Replies
- 26
- Views
- 1,633
Thanks R-12rules, I'll check into that...
Thanks R-12rules,
I'll check into that tomorrow morning at work and get those temps, as for as the other posts w/ questions i've looked at the wall construction and the whole inside is aluminum... -
09-12-2006, 02:28 PM
Thread: Help with Walk-in Refer.
by bubbahotemp- Replies
- 26
- Views
- 1,633
Storage range for walk-in required is 33-40* F,...
Storage range for walk-in required is 33-40* F, Humidity requirment is not an issue. I'm trying to get a temperature lower than 37*F to get a good spread so the unit does not short-cycle reducing...
-
09-12-2006, 02:07 PM
Thread: Help with Walk-in Refer.
by bubbahotemp- Replies
- 26
- Views
- 1,633
Thanks all for your replies, I have additional...
Thanks all for your replies, I have additional information
on my unit:
Evaporator coil:
Chandler Refrigeration
RLC067FS1: model
DXG10346 : Serial
TxV: Sporlan
GFE-1/2-C -
09-11-2006, 05:31 PM
Thread: Help with Walk-in Refer.
by bubbahotemp- Replies
- 26
- Views
- 1,633
Hey anybody I appreciate any help with some...
Hey anybody I appreciate any help with some questions I have concerning Walk-in Refrigerator.
I'm having some problems with this walk-in not reaching below 37 F. It's an r-12 water-cooled...